15
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      A comparison of intrauterine balloon, intrauterine contraceptive device and hyaluronic acid gel in the prevention of adhesion reformation following hysteroscopic surgery for Asherman syndrome: a cohort study.

      European Journal of Obstetrics, Gynecology, and Reproductive Biology
      Adult, Cohort Studies, Female, Gels, Gynatresia, pathology, prevention & control, surgery, Humans, Hyaluronic Acid, therapeutic use, Hysteroscopy, Intrauterine Devices, Retrospective Studies, Secondary Prevention, Uterus, Viscosupplements, Young Adult

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To compare the efficacy of intrauterine balloon, intrauterine contraceptive device and hyaluronic acid gel in the prevention of the adhesion reformation after hysteroscopic adhesiolysis for Asherman's syndrome. Retrospective cohort study of 107 women with Asherman's syndrome who were treated with hysteroscopic division of intrauterine adhesions. After hysteroscopic adhesiolysis, 20 patients had intrauterine balloon inserted, 28 patients had intrauterine contraceptive device (IUD) fitted, 18 patients had hyaluronic acid gel instilled into the uterine cavity, and 41 control subjects did not have any of the three additional treatment measures. A second-look hysteroscopy was performed in all cases, and the effect of hysteroscopic adhesiolysis was scored by the American Fertility Society classification system. Both the intrauterine balloon group and the IUD group achieved significantly (P<0.001) greater reduction in the adhesion score than that of the hyaluronic acid gel group and control group. The efficacy of the balloon was greater than that of the IUD (P<0.001). There was no significant difference in results between the hyaluronic acid gel group and the control groups. The insertion of an intrauterine balloon or intrauterine device is more effective than the use of hyaluronic acid gel in the prevention of intra-uterine adhesion reformation. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article