34
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      MineLoC: A Rapid Production of Lab-on-a-Chip Biosensors Using 3D Printer and the Sandbox Game, Minecraft

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Here, MineLoC is described as a pipeline developed to generate 3D printable models of master templates for Lab-on-a-Chip (LoC) by using a popular multi-player sandbox game “Minecraft”. The user can draw a simple diagram describing the channels and chambers of the Lab-on-a-Chip devices with pre-registered color codes which indicate the height of the generated structure. MineLoC converts the diagram into large chunks of blocks (equal sized cube units composing every object in the game) in the game world. The user and co-workers can simultaneously access the game and edit, modify, or review, which is a feature not generally supported by conventional design software. Once the review is complete, the resultant structure can be exported into a stereolithography (STL) file which can be used in additive manufacturing. Then, the Lab-on-a-Chip device can be fabricated by the standard protocol to produce a Lab-on-a-Chip. The simple polydimethylsiloxane (PDMS) device for the bacterial growth measurement used in the previous research was copied by the proposed method. The error calculation by a 3D model comparison showed an accuracy of 86%. It is anticipated that this work will facilitate more use of 3D printer-based Lab-on-a-Chip fabrication, which greatly lowers the entry barrier in the field of Lab-on-a-Chip research.

          Related collections

          Most cited references31

          • Record: found
          • Abstract: found
          • Article: not found

          Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels.

          This protocol describes a simple but robust microfluidic assay combining three-dimensional (3D) and two-dimensional (2D) cell culture. The microfluidic platform comprises hydrogel-incorporating chambers between surface-accessible microchannels. By using this platform, well-defined biochemical and biophysical stimuli can be applied to multiple cell types interacting over distances of <1 mm, thereby replicating many aspects of the in vivo microenvironment. Capabilities exist for time-dependent manipulation of flow and concentration gradients as well as high-resolution real-time imaging for observing spatial-temporal single-cell behavior, cell-cell communication, cell-matrix interactions and cell population dynamics. These heterotypic cell type assays can be used to study cell survival, proliferation, migration, morphogenesis and differentiation under controlled conditions. Applications include the study of previously unexplored cellular interactions, and they have already provided new insights into how biochemical and biophysical factors regulate interactions between populations of different cell types. It takes 3 d to fabricate the system and experiments can run for up to several weeks.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Configurable 3D-Printed millifluidic and microfluidic 'lab on a chip' reactionware devices.

            We utilise 3D design and 3D printing techniques to fabricate a number of miniaturised fluidic 'reactionware' devices for chemical syntheses in just a few hours, using inexpensive materials producing reliable and robust reactors. Both two and three inlet reactors could be assembled, as well as one-inlet devices with reactant 'silos' allowing the introduction of reactants during the fabrication process of the device. To demonstrate the utility and versatility of these devices organic (reductive amination and alkylation reactions), inorganic (large polyoxometalate synthesis) and materials (gold nanoparticle synthesis) processes were efficiently carried out in the printed devices.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              PDMS lab-on-a-chip fabrication using 3D printed templates.

              The fabrication of conventional PDMS on glass lab-on-a-chip (LOC) devices, using templates printed with a commercial (2299 US$) micro-stereo lithography 3D printer, is demonstrated. Printed templates replace clean room and photolithographic fabrication resources and deliver resolutions of 50 μm, and up to 10 μm in localized hindrances, whereas the templates are smooth enough to allow direct transfer and proper sealing to glass substrates. 3D printed templates accommodate multiple thicknesses, from 50 μm up to several mm within the same template, with no additional processing cost or effort. This capability is exploited to integrate silicone tubing easily, to improve micromixer performance and to produce multilevel fluidics with simple access to independent functional surfaces, which is illustrated by time-resolved glucose detection. The templates are reusable, can be fabricated in under 20 min, with an average cost of 0.48 US$, which promotes broader access to established LOC configurations with minimal fabrication requirements, relieves LOC fabrication from design skills and provides a versatile LOC development platform.
                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                10 June 2018
                June 2018
                : 18
                : 6
                : 1896
                Affiliations
                [1 ]Robotics Program, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Daejeon 34141, Korea; kkim0214@ 123456kaist.ac.kr
                [2 ]Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Daejeon 34141, Korea; hkkim1227@ 123456kaist.ac.kr (H.K.); ksg5825@ 123456kaist.ac.kr (S.K.)
                [3 ]KAIST Institute for Health Science and Technology, 291 Daehak-ro, Daejeon 34141, Korea
                Author notes
                [* ]Correspondence: jsjeon@ 123456kaist.ac.kr ; Tel.: +82-42-350-3226
                [†]

                These authors contributed equally to this work.

                Author information
                https://orcid.org/0000-0001-8694-4659
                https://orcid.org/0000-0003-0661-4583
                https://orcid.org/0000-0001-6690-5775
                Article
                sensors-18-01896
                10.3390/s18061896
                6021845
                29890772
                7d454648-ff30-4fd6-b2b7-767d0fc95e8d
                © 2018 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 17 April 2018
                : 07 June 2018
                Categories
                Article

                Biomedical engineering
                lab-on-a-chip,3d printing,additive manufacturing,microfluidics,solid modeling

                Comments

                Comment on this article