      Novel echocardiographic parameters of aortic insufficiency in continuous-flow left ventricular assist devices and clinical outcome

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <div class="section"> <a class="named-anchor" id="S1"> <!-- named anchor --> </a> <h5 class="section-title" id="d6880588e224">BACKGROUND</h5> <p id="P1">The aim of this study was to evaluate the prognostic performance of novel echocardiographic (transthoracic echocardiography, or TTE) parameters for grading aortic insufficiency (AI) severity in patients with continuous-flow left ventricular assist devices (CF-LVADs). The development of AI after CF-LVAD implantation is common, although the clinical significance remains unclear. We previously described novel TTE parameters that outperformed traditional TTE parameters in grading AI severity in these patients. </p> </div><div class="section"> <a class="named-anchor" id="S2"> <!-- named anchor --> </a> <h5 class="section-title" id="d6880588e229">METHODS</h5> <p id="P2">CF-LVAD patients with varying degrees of AI ( <i>N</i> = 57) underwent Doppler TTE of the LVAD outflow cannula. Patients had AI severity graded by the novel parameters (systolic/diastolic velocity ratio and the diastolic acceleration of the LVAD outflow cannula) and the traditional vena contracta. The prognostic performance of novel and traditional AI parameters was determined by comparing rates of congestive heart failure re-admission, need for aortic valve intervention, urgent transplantation and death (composite end-points) for each parameter. </p> </div><div class="section"> <a class="named-anchor" id="S3"> <!-- named anchor --> </a> <h5 class="section-title" id="d6880588e237">RESULTS</h5> <p id="P3">Grading AI severity using novel AI parameters led to reclassification of 32% of patients from trace/mild AI to moderate or greater AI ( <i>N</i> =18). Using traditional AI parameters, there was no difference in the occurrence of the composite end-point between the moderate or greater group and the trace/mild group (1.50 vs 1.18 events/person, <i>p</i> = 0.46). With the novel AI parameters, there were significantly more events in the patients with moderate or greater AI compared to those with trace/mild AI (1.57 vs 0.13 events/person, <i>p</i> = 0.002). Novel parameters also better predicted the need for aortic valve intervention, urgent transplantation or death than traditional methods ( <i>p</i> = 0.024 vs <i>p</i> = 0.343). </p> </div><div class="section"> <a class="named-anchor" id="S4"> <!-- named anchor --> </a> <h5 class="section-title" id="d6880588e257">CONCLUSIONS</h5> <p id="P4">In patients with CF-LVADs, traditional parameters tend to underestimate AI severity and future cardiac events. Novel AI TTE parameters are better able to discriminate AI severity and predict clinically meaningful outcomes. </p> </div>

          Related collections

          Author and article information

          Journal
          The Journal of Heart and Lung Transplantation
          The Journal of Heart and Lung Transplantation
          Elsevier BV
          10532498
          August 2016
          August 2016
          : 35
          : 8
          : 976-985
          Article
          10.1016/j.healun.2016.05.009
          5393266
          27373822
          7e70ad99-a5b3-4b8f-862f-955927a55581
          © 2016

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article