      Estimation of skull table thickness with clinical CT and validation with microCT

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies.

          Related collections

          Author and article information

          Journal
          J Anat
          J. Anat
          joa
          Journal of Anatomy
          Blackwell Science Inc (Oxford, UK )
          0021-8782
          1469-7580
          January 2015
          01 December 2014
          : 226
          : 1
          : 73-80
          Affiliations
          [1 ] Virginia Tech-Wake Forest University Center for Injury Biomechanics Winston-Salem, NC, USA
          [2 ] Wake Forest University School of Medicine Winston-Salem, NC, USA
          [3 ] Department of Neurosurgery, Wake Forest University Winston-Salem, NC, USA
          Author notes
          Joel D. Stitzel, Ph.D, Professor, Virginia Tech-Wake Forest University Center for Injury Biomechanics, Medical Center Blvd., Winston-Salem, NC 27157, USA. T: + 1 336 7165597; F: + 1 336 4589306; E: jdstitzel@ 123456gmail.com
          Article
          PMC4313900 PMC4313900 4313900
          10.1111/joa.12259
          4313900
          25441171
          7e83b19b-8cc1-439e-89b4-cdca2da69645
          © 2014 Anatomical Society
          History
          : 14 October 2014
          Categories
          Original Articles

          skull,computed tomography,cortex,thickness
          skull, computed tomography, cortex, thickness

          Comments

          Comment on this article