      • Record: found
      • Abstract: found
      • Article: not found

      Safety of the APOLLO Onyx delivery microcatheter for embolization of brain arteriovenous malformations: results from a prospective post-market study

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Catheter retention and difficulty in retrieval have been observed during embolization of brain arteriovenous malformations (bAVMs) with the Onyx liquid embolic system (Onyx). The Apollo Onyx delivery microcatheter (Apollo) is a single lumen catheter designed for controlled delivery of Onyx into the neurovasculature, with a detachable distal tip to aid catheter retrieval. This study evaluates the safety of the Apollo for delivery of Onyx during embolization of bAVMs.

          Methods

          This was a prospective, non-randomized, single-arm, multicenter, post-market study of patients with a bAVM who underwent Onyx embolization with the Apollo between May 2015 and February 2018. The primary endpoint was any catheter-related adverse event (AE) at 30 days, such as unintentional tip detachment or malfunction with clinical sequelae, or retained catheter. Procedure-related AEs (untoward medical occurrence, disease, injury, or clinical signs) and serious AEs (life threatening illness or injury, permanent physiological impairment, hospitalization, or requiring intervention) were also recorded.

          Results

          A total of 112 patients were enrolled (mean age 44.1±17.6 years, 56.3% men), and 201 Apollo devices were used in 142 embolization procedures. The mean Spetzler–Martin grade was 2.38. The primary endpoint was not observed (0/112, 0%). The catheter tip detached during 83 (58.5%) procedures, of which 2 (2.4%) were unintentional and did not result in clinical sequelae. At 30 days, procedure related AEs occurred in 26 (23.2%) patients, and procedure-related serious AEs in 12 (10.7%). At 12 months, there were 3 (2.7%) mortalities, including 2 (1.8%) neurological deaths, none of which were device-related.

          Conclusion

          This study demonstrates the safety of Apollo for Onyx embolization of bAVMs.

          Clinical trial registration

          CNCT02378883.

          Related collections

          Most cited references40

          • Record: found
          • Abstract: found
          • Article: not found

          Medical management with or without interventional therapy for unruptured brain arteriovenous malformations (ARUBA): a multicentre, non-blinded, randomised trial.

          The clinical benefit of preventive eradication of unruptured brain arteriovenous malformations remains uncertain. A Randomised trial of Unruptured Brain Arteriovenous malformations (ARUBA) aims to compare the risk of death and symptomatic stroke in patients with an unruptured brain arteriovenous malformation who are allocated to either medical management alone or medical management with interventional therapy.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Predictors of hemorrhage in patients with untreated brain arteriovenous malformation.

            Intracranial hemorrhage is a serious possible complication in patients with brain arteriovenous malformation (AVM). Several morphologic factors associated with hemorrhagic AVM presentation have been established, but their relevance for the risk of subsequent AVM hemorrhage remains unclear. The authors analyzed follow-up data on 622 consecutive patients from the prospective Columbia AVM database, limited to the period between initial AVM diagnosis and the start of treatment (i.e., any endovascular, surgical, or radiation therapy). Univariate and multivariate logistic regression and Cox proportional hazard models were applied to analyze the effect of patient age, gender, AVM size, anatomic location, venous drainage pattern, and associated arterial aneurysms on the risk of intracranial hemorrhage at initial presentation and during follow-up. The mean pretreatment follow-up was 829 days (median: 102 days), during which 39 (6%) patients experienced AVM hemorrhage. Increasing age (hazard ratio [HR] 1.05, 95% CI 1.03 to 1.08), initial hemorrhagic AVM presentation (HR 5.38, 95% CI 2.64 to 10.96), deep brain location (HR 3.25, 95% CI 1.30 to 8.16), and exclusive deep venous drainage (HR 3.25, 95% CI 1.01 to 5.67) were independent predictors of subsequent hemorrhage. Annual hemorrhage rates on follow-up ranged from 0.9% for patients without hemorrhagic AVM presentation, deep AVM location, or deep venous drainage to as high as 34.4% for those harboring all three risk factors. Hemorrhagic arteriovenous malformation (AVM) presentation, increasing age, deep brain location, and exclusive deep venous drainage appear to be independent predictors for AVM hemorrhage during natural history follow-up. The risk of spontaneous hemorrhage may be low in AVMs without these risk factors.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Natural history of cerebral arteriovenous malformations: a meta-analysis.

              The purpose of this report was to provide overall arteriovenous malformation (AVM) hemorrhage rates and, with enhanced statistical power, to elucidate significant risk factors for hemorrhage.
                Bookmark

                Author and article information

                Contributors
                Journal
                Journal of NeuroInterventional Surgery
                J NeuroIntervent Surg
                BMJ
                1759-8478
                1759-8486
                September 15 2021
                October 2021
                October 2021
                February 01 2021
                : 13
                : 10
                : 935-941
                Article
                10.1136/neurintsurg-2020-016830
                7ede99d9-586b-437f-b7eb-d4abfa72527d
                © 2021
                History

                Comments

                Comment on this article