      Electrophysiologic properties of pulmonary veins assessed using a multielectrode basket catheter.

      Journal of the American College of Cardiology
      Adult, Aged, Atrial Fibrillation, diagnosis, physiopathology, surgery, Body Surface Potential Mapping, Cardiac Pacing, Artificial, Catheter Ablation, Catheters, Indwelling, Electric Stimulation, Electrocardiography, Ambulatory, Electrodes, Implanted, Electrophysiologic Techniques, Cardiac, instrumentation, Female, Heart Atria, Heart Conduction System, pathology, Humans, Male, Middle Aged, Pulmonary Veins, Refractory Period, Electrophysiological, physiology, Treatment Outcome

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The purpose of the present study was to evaluate the electrophysiologic properties within the pulmonary vein (PV) and at the PV-left atrial (LA) junction. It has been recognized that atrial fibrillation (AF) can originate from PVs. However, the electrophysiologic properties of the PV have not been well characterized. Thirty-two bipolar electrograms were recorded simultaneously from a basket catheter placed in 81 PVs of 48 patients with paroxysmal AF. The programmed stimulation was performed in the distal PV and PV-LA junction. Activation maps of PVs were analyzed from episodes of spontaneous onset of AF and initiation of induced AF by a single extrastimulus. The effective refractory period (ERP) of the distal PV was significantly shorter than that of the PV-LA junction (177 +/- 43 vs. 222 +/- 30 ms, p < 0.0001). The conduction delay from the distal PV to the PV-LA junction was significantly longer than that from the PV-LA junction to distal PV (73 +/- 40 vs. 32 +/- 17 ms, p < 0.0001). During initiation of AF, a short coupled extrastimulus or rapid, repetitive focal activities originating from the PV formed a PV-LA reciprocating re-entrant circuit involving exit and entrance breakthrough points at the PV-LA junction. Also, an unstable re-entrant circuit within the PV was observed. The presence of ERP heterogeneity and anisotropic conduction properties within the PV and at the PV-LA junction may be crucial to promote re-entry formation and thus might play an important role as a substrate for the maintenance of AF.

          Related collections

          Author and article information

          Comments

          Comment on this article