0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      The use of iohexol clearance to determine GFR in patients with severe chronic renal failure--a comparison between different clearance techniques.

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The nonionic low-osmolar contrast medium iohexol was used as marker of glomerular filtration rate (GFR) in 53 patients with stable renal function (group I: n = 32, group II: n = 21). All the patients had clearance values < or = 30 ml.min-1.1.73 m-2 body surface; 40 patients < 20 ml.min-1.1.73 m-2 body surface. Simultaneous determinations of renal clearance and plasma clearance, both as slope clearance and single sample clearance, were performed after intravenous injection of 10 ml iohexol 300 mg iodine/ml. In groups I and II plasma was sampled early (around 3 hours) and late (up to 24 hours) after the injection. In group I urine was collected during four 40-minute periods and in group II during one 3-hour period and in group II the residual urine was estimated by ultrasound. Plasma and urine iodine concentrations were analyzed with X-ray fluorescence technique (Reanalyzer PRX90, Provalid AB, Sweden). In group II S-creatinine and tubular function test were followed to detect any signs of nephrotoxicity. In 6 anuric patients (group III) 10 ml iohexol 300 mg I/ml was injected to assess its extrarenal clearance. In groups I and II the slope clearance correlated excellently with the single sample clearance (r = 0.99) when a late plasma sample was used in both techniques. In group II, where residual urine was estimated by ultrasound, renal clearance correlated better with slope clearance than in group I (r = 0.94 vs r = 0.89). There were no signs of nephrotoxicity in the parameters noted. In group III, extrarenal plasma clearance of iohexol did not exceed 2 ml.min-1.1.73 m-2.

          Related collections

          Author and article information

          Journal
          Clin. Nephrol.
          Clinical nephrology
          0301-0430
          0301-0430
          Jan 1995
          : 43
          : 1
          Affiliations
          [1 ] Department of Diagnostic Radiology, Malmö General Hospital, University of Lund, Sweden.
          Article
          7697934
          7f7a5647-b477-4bb1-b412-74564c46d009
          History

          Comments

          Comment on this article