11
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Catéteres venosos periféricos innecesarios en la zona ambulatoria de un servicio de urgencias Translated title: Unnecessary peripheral venous catheters in ambulatory emergency care

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Resumen

          El objetivo de este estudio fue estimar la frecuencia de canalización innecesaria de catéteres venosos periféricos (CVP) en pacientes adultos atendidos en la zona ambulatoria del servicio de urgencias, y analizar potenciales factores asociados.

          Se realizó un estudio transversal exploratorio en un hospital de tercer nivel durante dos meses consecutivos. Se calculó la proporción de CVP insertados y no utilizados, y se relacionó con variables del paciente.

          A 701 pacientes se les insertó un CVP, en 103 (14,7%; IC95%: 12,1-17,3) el catéter no llegó a ser utilizado, siendo dados de alta directamente a domicilio. La edad superior a 64 años se asoció a una mayor tasa de inadecuación (19,3 vs 10,8%; p=0,002).

          Parece existir cierta proporción de catéteres canalizados de forma innecesaria en el área ambulatoria urgencias, lo que justificaría la implantación de programas de buenas prácticas en la valoración y selección de accesos vasculares

          Abstract

          The aim of this study was to estimate the frequency of unnecessary peripheral venous catheter (PVC) cannulation in adult patients attended in Ambulatory Emergency Care, and to analyse potential associated factors.

          An exploratory cross-sectional study was conducted in a tertiary hospital for two consecutive months. The proportion of canulated and unused PVC was calculated and related to patient variables.

          A PVC was cannulated in 701 patients. In 103 cases (14.7%; 95%CI: 12.1-17.3) the catheter was not used, and the patients were discharged directly home. Age over 64 was associated with a higher proportion of unsuitability (19.3% vs. 10.8%; p=0.002).

          There seems to be a certain proportion of catheters cannulated unnecessarily in Ambulatory Emergency Care, which would justify the implementation of good practice programmes in the assessment and selection of vascular accesses.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: not found
          • Article: not found

          Peripheral Intravenous Cannula Insertion and Use in the Emergency Department: An Intervention Study

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Review article: Idle ‘just-in-case’ peripheral intravenous cannulas in the emergency department: Is something wrong?

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Utility of peripheral intravenous cannulae inserted in one tertiary referral emergency department: A medical record audit

                Bookmark

                Author and article information

                Journal
                An Sist Sanit Navar
                An Sist Sanit Navar
                assn
                Anales del Sistema Sanitario de Navarra
                Gobierno de Navarra. Departamento de Salud
                1137-6627
                2340-3527
                29 June 2022
                May-Aug 2022
                : 45
                : 2
                : e0998
                Affiliations
                [1 ] originalBiocruces Bizkaia Health Research Institute. Barakaldo. España. orgnameBiocruces Bizkaia Health Research Institute Barakaldo, España
                [2 ] originalOsakidetza. Hospital Santa Marina. Bilbao. España. orgnameOsakidetza orgdiv1Hospital Santa Marina Bilbao, España
                [3 ] originalUniversidad del País Vasco / Euskal Herriko Unibertsitatea (UPV/EHU). España. normalizedUniversidad del País Vasco orgnameUniversidad del País Vasco / Euskal Herriko Unibertsitatea Spain
                [4 ] originalOsakidetza. Hospital de Basurto. Bilbao. España. orgnameOsakidetza orgdiv1Hospital de Basurto Bilbao, España
                Author notes
                [Correspondencia ] Sendoa Ballesteros-Peña. Enfermería Hospital de Santa Marina Carretera de Santa Marina, 41, 48004, Bilbao, Bizkaia, España. Email: sendoa.ballesteros@ 123456ehu.eus

                Conflictos de intereses: Los autores declaran no tener conflictos de intereses.

                Article
                10.23938/ASSN.0998
                10123453
                35781469
                7fe5d86d-39fa-4df4-9752-7b3f018decc8

                Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons

                History
                : 28 December 2021
                : 05 January 2022
                : 12 January 2022
                Page count
                Figures: 0, Tables: 2, Equations: 0, References: 12, Pages: 0
                Categories
                Artículos Originales Breves

                catéteres,dispositivos de acceso vascular,atención ambulatoria,servicios médicos de urgencia,catheters,vascular access devices,ambulatory care,emergency medical services

                Comments

                Comment on this article