14
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction

          Obstructive sleep apnea (OSA) is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS) and continuous positive airway pressure (CPAP) on fluid shift is barely known. We compared the effects of CS and CPAP on fluid dynamics in a sample of patients with OSA in hemodialysis, through a randomized crossover study.

          Methods

          Each participant performed polysomnography (PSG) at baseline, during CPAP titration, and after 1 week of wearing CS. Neck circumference (NC) and segmental bioelectrical impedance were done before and after PSG.

          Results

          Fourteen patients were studied (53 ± 9 years; 57% men; body mass index 29.7 ± 6.8 kg/m 2). Apnea–hypopnea index (AHI) decreased from 20.8 (14.2; 39.6) at baseline to 7.9 (2.8; 25.4) during CPAP titration and to 16.7 (3.5; 28.9) events/h after wearing CS (CPAP vs. baseline, p = 0.004; CS vs. baseline, p = 0.017; and CPAP vs. CS, p = 0.017). Nocturnal intracellular trunk water was higher after wearing CS in comparison to baseline and CPAP ( p = 0.03). CS reduced the fluid accumulated in lower limbs during the day, although not significantly. Overnight fluid shift at baseline, CPAP, and CS was −183 ± 72, −343 ± 220, and −290 ± 213 ml, respectively ( p = 0.006). Overnight NC increased at baseline (0.7 ± 0.4 cm), decreased after CPAP (−1.0 ± 0.4 cm), and while wearing CS (−0.4 ± 0.8 cm) (CPAP vs. baseline, p < 0.0001; CS vs. baseline, p = 0.001; CPAP vs. CS, p = 0.01).

          Conclusion

          CS reduced AHI by avoiding fluid retention in the legs, favoring accumulation of water in the intracellular component of the trunk, thus avoiding fluid shift to reach the neck. CPAP improved OSA by exerting local pressure on upper airway, with no impact on fluid redistribution. CPAP performed significantly better than CS for both reduction of AHI and overnight reduction of NC. Complementary studies are needed to elucidate the mechanisms by which CPAP and CS reduce NC.

          Related collections

          Most cited references34

          • Record: found
          • Abstract: not found
          • Article: not found

          Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Sleep-disordered breathing and cardiovascular disease: cross-sectional results of the Sleep Heart Health Study.

            Disordered breathing during sleep is associated with acute, unfavorable effects on cardiovascular physiology, but few studies have examined its postulated association with cardiovascular disease (CVD). We examined the cross-sectional association between sleep- disordered breathing and self-reported CVD in 6,424 free-living individuals who underwent overnight, unattended polysomnography at home. Sleep-disordered breathing was quantified by the apnea-hypopnea index (AHI)-the average number of apneas and hypopneas per hour of sleep. Mild to moderate disordered breathing during sleep was highly prevalent in the sample (median AHI: 4.4; interquartile range: 1.3 to 11.0). A total of 1,023 participants (16%) reported at least one manifestation of CVD (myocardial infarction, angina, coronary revascularization procedure, heart failure, or stroke). The multivariable-adjusted relative odds (95% CI) of prevalent CVD for the second, third, and fourth quartiles of the AHI (versus the first) were 0.98 (0.77-1.24), 1.28 (1.02-1.61), and 1.42 (1.13-1.78), respectively. Sleep-disordered breathing was associated more strongly with self-reported heart failure and stroke than with self-reported coronary heart disease: the relative odds (95% CI) of heart failure, stroke, and coronary heart disease (upper versus lower AHI quartile) were 2.38 (1.22-4.62), 1.58 (1.02- 2.46), and 1.27 (0.99-1.62), respectively. These findings are compatible with modest to moderate effects of sleep-disordered breathing on heterogeneous manifestations of CVD within a range of AHI values that are considered normal or only mildly elevated.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Association of sleep-disordered breathing, sleep apnea, and hypertension in a large community-based study. Sleep Heart Health Study.

              Sleep-disordered breathing (SDB) and sleep apnea have been linked to hypertension in previous studies, but most of these studies used surrogate information to define SDB (eg, snoring) and were based on small clinic populations, or both. To assess the association between SDB and hypertension in a large cohort of middle-aged and older persons. Cross-sectional analyses of participants in the Sleep Heart Health Study, a community-based multicenter study conducted between November 1995 and January 1998. A total of 6132 subjects recruited from ongoing population-based studies (aged > or = 40 years; 52.8% female). Apnea-hypopnea index (AHI, the average number of apneas plus hypopneas per hour of sleep, with apnea defined as a cessation of airflow and hypopnea defined as a > or = 30% reduction in airflow or thoracoabdominal excursion both of which are accompanied by a > or = 4% drop in oxyhemoglobin saturation) [corrected], obtained by unattended home polysomnography. Other measures include arousal index; percentage of sleep time below 90% oxygen saturation; history of snoring; and presence of hypertension, defined as resting blood pressure of at least 140/90 mm Hg or use of antihypertensive medication. Mean systolic and diastolic blood pressure and prevalence of hypertension increased significantly with increasing SDB measures, although some of this association was explained by body mass index (BMI). After adjusting for demographics and anthropometric variables (including BMI, neck circumference, and waist-to-hip ratio), as well as for alcohol intake and smoking, the odds ratio for hypertension, comparing the highest category of AHI (> or = 30 per hour) with the lowest category ( or = 12% vs < 0.05%) was 1.46 (95% CI, 1.12-1.88; P for trend <.001). In stratified analyses, associations of hypertension with either measure of SDB were seen in both sexes, older and younger ages, all ethnic groups, and among normal-weight and overweight individuals. Weaker and nonsignificant associations were observed for the arousal index or self-reported history of habitual snoring. Our findings from the largest cross-sectional study to date indicate that SDB is associated with systemic hypertension in middle-aged and older individuals of different sexes and ethnic backgrounds.
                Bookmark

                Author and article information

                Contributors
                URI : http://frontiersin.org/people/u/426196
                URI : http://frontiersin.org/people/u/437131
                URI : http://frontiersin.org/people/u/50741
                URI : http://frontiersin.org/people/u/437224
                URI : http://frontiersin.org/people/u/415258
                Journal
                Front Med (Lausanne)
                Front Med (Lausanne)
                Front. Med.
                Frontiers in Medicine
                Frontiers Media S.A.
                2296-858X
                19 May 2017
                2017
                : 4
                : 57
                Affiliations
                [1] 1Department of Medicine, Renal Division, Universidade de São Paulo , São Paulo, Brazil
                [2] 2Department of Medicine, Renal Division, Universidade Federal do Espírito Santo , Vitoria, Brazil
                [3] 3Instituto do Coração (InCor), Universidade de São Paulo , São Paulo, Brazil
                [4] 4Department of Psychobiology, Universidade Federal de São Paulo , São Paulo, Brazil
                [5] 5Department of Neurology and Neurosurgery, Universidade Federal de São Paulo , São Paulo, Brazil
                Author notes

                Edited by: Christos Argyropoulos, University of New Mexico, USA

                Reviewed by: Maria-Eleni Roumelioti, University of New Mexico Health Sciences Center (UNM HSC), USA; David J. Kennedy, University of Toledo, USA

                *Correspondence: Rosilene M. Elias, rosilenemotta@ 123456hotmail.com

                Specialty section: This article was submitted to Nephrology, a section of the journal Frontiers in Medicine

                Article
                10.3389/fmed.2017.00057
                5437164
                28580357
                80714112-1311-4a36-91b6-faecbaf531b2
                Copyright © 2017 Silva, Santos, Drager, Coelho and Elias.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 12 February 2017
                : 01 May 2017
                Page count
                Figures: 6, Tables: 3, Equations: 0, References: 45, Pages: 9, Words: 6471
                Funding
                Funded by: Fundação de Amparo à Pesquisa do Estado de São Paulo 10.13039/501100001807
                Award ID: 12/05236-0
                Categories
                Medicine
                Original Research

                obstructive sleep apnea,compression stockings,continuous positive airway pressure,fluid shift,hemodialysis

                Comments

                Comment on this article