      An Index for Human Lens Transparency Related to Age and Lens Layer: Comparison between Normal Volunteers and Diabetic Patients with Still Clear Lenses

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective: The light scattering intensity of normal, clear lenses varies with age and with the localization within the lens. Realizing the biometry of single lens areas together with their relevant light scattering intensity one should be able to calculate an index to express the lens transparency properties of normal human lenses in dependence on age. Performing the same procedure in cases of diabetic patients with still clear lenses it should become possible to obtain an index for the lens transparency properties of lenses under the ‘risk factor’ diabetes. Methods: 748 eyes with transparent lenses in 383 healthy individuals and 134 eyes with clear lenses in 70 subjects with diabetes were examined. Scheimpflug slit images of the lens were documented by a Nidek EAS-1000 instrument. Biometry for measuring the distance of the single lens layers from the anterior capsule and densitometry for determining the light scattering intensity of six defined lens layers along the (theoretical) optical axis were performed. The index of the lens transparency properties was calculated using the light scattering intensity of a defined lens layer and its distance from the anterior capsule. Results: Lens thickness and light scattering intensities increased linearly with increasing age in the normal population as well as in the diabetic patients. The densitogram pattern of the light scattering intensities in the defined representative six points was similar in both populations, but in the diabetic group the lens thickness was larger and the light scattering intensities were higher at all ages. Conclusion: The index of lens transparency properties calculated with the light scattering intensities of a certain lens area and its distance from the anterior capsule is a useful measure of lens clarity in dependence on age. ‘Clear’ lenses of the diabetic population show significantly higher indices for the lens transparency properties in all age groups.

          Related collections

          Author and article information

          Journal
          ORE
          Ophthalmic Res
          10.1159/issn.0030-3747
          Ophthalmic Research
          S. Karger AG
          978-3-8055-6825-8
          978-3-318-00395-6
          0030-3747
          1423-0259
          1999
          April 1999
          11 February 1999
          : 31
          : 2
          : 93-103
          Affiliations
          Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
          Article
          55519 Ophthalmic Res 1999;31:93–103
          10.1159/000055519
          9933770
          82504c4a-2944-4937-b04c-fb0dcc0a5584
          © 1999 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          Page count
          Figures: 7, Tables: 3, References: 15, Pages: 11
          Categories
          Paper

          Vision sciences,Ophthalmology & Optometry,Pathology
          Light scattering intensity,Clear human lens of diabetic patients,Lens thickness,Normal human lens,Scheimpflug photography,Lens transparency,Diabetes,Index for lens transparency

          Comments

          Comment on this article