      Clinical nerve reconstruction with a bioabsorbable polyglycolic acid tube.

      Plastic and Reconstructive Surgery
      Adult, Biocompatible Materials, therapeutic use, Fingers, innervation, surgery, Humans, Neurosurgical Procedures, Polyglycolic Acid, Prostheses and Implants

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Microneurosurgical techniques to reconstruct nerve gaps with nerve grafts frequently fail to achieve excellent functional results and create donor-site morbidity. In the present study, 15 patients had gaps of 0.5 to 3.0 cm (mean 1.7 cm) in digital nerves reconstructed by one surgeon with a bioabsorbable polyglycolic acid (PGA) tube. A final evaluation of sensibility was done by a second surgeon at a mean postoperative interval of 22.4 months (range 11 to 32 months). These were all secondary reconstructions. The evaluation included a digital nerve block with local anesthetic for the intact (not reconstructed) digital nerve. Excellent functional sensation (moving two-point discrimination less than or equal to 3 mm and/or static two-point discrimination less than or equal to 6 mm) was present in 33 percent and good functional sensation (moving two-point discrimination of 4 to 7 mm and/or static two-point discrimination of 7 to 15 mm) in 53 percent of the digital nerve reconstructions. One patient with poor sensory recovery and one with no recovery were judged as functional failures (14 percent). Absence of pain at the site of reconstruction was judged by the patient to be excellent in 40 percent, good in 33 percent, and poor in 27 percent. We conclude that reconstruction of nerve gaps of up to 3.0 cm with a bioabsorbable PGA tube gives clinical results at least comparable to the classic nerve graft technique while avoiding donor-site morbidity.

          Related collections

          Author and article information

          Journal
          2154831
          10.1097/00006534-199003000-00015

          Chemistry
          Adult,Biocompatible Materials,therapeutic use,Fingers,innervation,surgery,Humans,Neurosurgical Procedures,Polyglycolic Acid,Prostheses and Implants

          Comments

          Comment on this article