43
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Passive leg raising and compression stockings: a note of caution

      letter
      , ,
      Critical Care
      BioMed Central

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In a recent editorial in Critical Care, Monnet and Teboul emphasize the value of passive leg raising (PLR) as a reliable bedside indicator of fluid responsiveness in critically ill patients [1]. This is because PLR induces changes in venous return, regardless of the mode of ventilation or the underlying cardiac arrhythmias. In their eloquently written editorial, they provide five practical rules for performing a PLR maneuver. The authors state that during PLR about 300 mL of blood is auto-transfused from the lower limbs and splanchnic circulation into the central compartment, resulting in an increased cardiac output. This maneuver has been validated in cohorts of patients with either hypovolaemic or septic shock [2, 3]. It is a prerequisite of the test that the volume of blood that is auto-transfused be sufficient to increase mean circulatory pressure which drives venous return [3]. We hypothesize that this may not be the situation in all patients and that, if there is no change in cardiac output, blood pressure, or right atrial pressure [4], an inadequate volume of blood will be returned to the right heart. This may be relevant in patients with elastic compression stockings, which are widely used to prevent venous thromboembolism in critically ill patients. The effectiveness of PLR as a measure of fluid responsiveness can be compromised by elastic compression stockings [5]. Consequently, we would recommend that elastic compression stockings be routinely removed prior to the PLR maneuver.

          Related collections

          Most cited references6

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Passive leg raising: five rules, not a drop of fluid!

          In acute circulatory failure, passive leg raising (PLR) is a test that predicts whether cardiac output will increase with volume expansion [1]. By transferring a volume of around 300 mL of venous blood [2] from the lower body toward the right heart, PLR mimics a fluid challenge. However, no fluid is infused and the hemodynamic effects are rapidly reversible [1,3], thereby avoiding the risks of fluid overload. This test has the advantage of remaining reliable in conditions in which indices of fluid responsiveness that are based on the respiratory variations of stroke volume cannot be used [1], like spontaneous breathing, arrhythmias, low tidal volume ventilation, and low lung compliance. The method for performing PLR is of the utmost importance because it fundamentally affects its hemodynamic effects and reliability. In practice, five rules should be followed. First, PLR should start from the semi-recumbent and not the supine position (Figure 1). Adding trunk lowering to leg raising should mobilize venous blood from the large splanchnic compartment, thus magnifying the increasing effects of leg elevation on cardiac preload [2] and increasing the test’s sensitivity. A study that did not comply with this rule misleadingly reported a poor reliability of PLR [4]. Figure 1 The best method for passive leg raising, indicating the five rules to be followed. CO, cardiac output; PLR, passive leg raising. Second, the PLR effects must be assessed by a direct measurement of cardiac output and not by the simple measurement of blood pressure. Indeed, reliability of PLR is poorer when assessed by using arterial pulse pressure compared with cardiac output [1,5]. Although the peripheral arterial pulse pressure is positively correlated with stroke volume, it also depends on arterial compliance and pulse wave amplification. The latter phenomenon could be altered during PLR, impeding the use of pulse pressure as a surrogate of stroke volume to assess PLR effects. Third, the technique used to measure cardiac output during PLR must be able to detect short-term and transient changes since the PLR effects may vanish after 1 minute [1]. Techniques monitoring cardiac output in ‘real time’, such as arterial pulse contour analysis, echocardiography, esophageal Doppler, or contour analysis of the volume clamp-derived arterial pressure, can be used [6]. Conflicting results have been reported for bioreactance [7,8]. The hemodynamic response to PLR can even be assessed by the changes in end-tidal exhaled carbon dioxide, which reflect the changes in cardiac output in the case of constant minute ventilation [5]. Fourth, cardiac output must be measured not only before and during PLR but also after PLR when the patient has been moved back to the semi-recumbent position, in order to check that it returns to its baseline (Figure 1). Indeed, in unstable patients, cardiac output changes during PLR could result from spontaneous variations inherent to the disease and not from cardiac preload changes. Fifth, pain, cough, discomfort, and awakening could provoke adrenergic stimulation, resulting in mistaken interpretation of cardiac output changes. Some simple precautions must be taken to avoid these confounding factors (Figure 1). PLR must be performed by adjusting the bed and not by manually raising the patient’s legs. Bronchial secretions must be carefully aspirated before PLR. If awake, the patient should be informed of what the test involves. A misleading sympathetic stimulation can be suspected if PLR is accompanied by a significant increase in heart rate, which normally should not occur. It has been suggested that PLR is unreliable in the case of intra-abdominal hypertension [9]. The increased abdominal weight was hypothesized to squeeze the inferior vena cava in the raised-leg position [10]. Nevertheless, the single study investigating this issue did not confirm the hypothesis since intra-abdominal pressure was not measured during PLR [9]. Furthermore, one could hypothesize that PLR reduces rather than increases the intra-abdominal pressure by relieving the weight of the diaphragm on the abdominal cavity. Provided that these simple rules are followed, the PLR test reliably predicts preload responsiveness [11]. Because it has no side effects, PLR should be considered as a replacement for the classic fluid challenge [12]. The main drawback of the fluid challenge is that, if it is negative, fluid has nonetheless been irreversibly administered to the patient. Repeated fluid challenges therefore can lead to fluid overload. In this regard, PLR is an attractive method of challenging preload without administering one drop of fluid. Importantly, it should be remembered that detection of preload responsiveness by a positive PLR test should not routinely lead to fluid administration. Indeed, the decision to administer fluid must always be made individually on the basis of the mandatory presence of the three following situations: hemodynamic instability or signs of circulatory shock (or both), preload responsiveness (positive PLR test), and limited risks of fluid overload. Also, a negative PLR test should contribute mainly to the decision to stop or discontinue fluid infusion, in order to avoid fluid overload, suggesting that hemodynamic instability should be corrected by means other than fluid administration.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Passive leg raising.

            To assess whether the passive leg raising test can help in predicting fluid responsiveness. Nonsystematic review of the literature. Passive leg raising has been used as an endogenous fluid challenge and tested for predicting the hemodynamic response to fluid in patients with acute circulatory failure. This is now easy to perform at the bedside using methods that allow a real time measurement of systolic blood flow. A passive leg raising induced increase in descending aortic blood flow of at least 10% or in echocardiographic subaortic flow of at least 12% has been shown to predict fluid responsiveness. Importantly, this prediction remains very valuable in patients with cardiac arrhythmias or spontaneous breathing activity. Passive leg raising allows reliable prediction of fluid responsiveness even in patients with spontaneous breathing activity or arrhythmias. This test may come to be used increasingly at the bedside since it is easy to perform and effective, provided that its effects are assessed by a real-time measurement of cardiac output.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Applying mean systemic filling pressure to assess the response to fluid boluses in cardiac post-surgical patients.

              To evaluate an analogue of mean systemic filling pressure (P(msa)) and derived variables to quantitatively assess the effectiveness of volume expansion in increasing cardiac output.
                Bookmark

                Author and article information

                Contributors
                cjchacko@yahoo.com
                Journal
                Crit Care
                Critical Care
                BioMed Central (London )
                1364-8535
                1466-609X
                1 June 2015
                1 June 2015
                2015
                : 19
                : 1
                : 237
                Affiliations
                Critical Care Unit, University Hospital of Wales, Heath Park, Cardiff, CF14 4XW Wales, UK
                Article
                955
                10.1186/s13054-015-0955-0
                4450449
                26028257
                863b2e34-d3dc-4e17-a610-ed9e888bb78c
                © Chacko et al.; licensee BioMed Central. 2015

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                Categories
                Letter
                Custom metadata
                © The Author(s) 2015

                Emergency medicine & Trauma
                Emergency medicine & Trauma

                Comments

                Comment on this article