      Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Three-dimensional dosimetry with good spatial resolution can be performed using polymer gel dosimetry, which has been investigated for dosimetry of different types of particles. However, there are only sparse data concerning the influence of the linear energy transfer (LET) properties of the radiation on the gel absorbed dose response. The purpose of this study was to investigate possible LET dependence for a polymer gel dosimeter using proton beam absorbed dose measurements. Polymer gel containing the antioxidant tetrakis(hydroxymethyl)phosphonium (THP) was irradiated with 133 MeV monoenergetic protons, and the gel absorbed dose response was evaluated using MRI. The LET distribution for a monoenergetic proton beam was calculated as a function of depth using the Monte Carlo code PETRA. There was a steep increase in the Monte Carlo calculated LET starting at the depth corresponding to the front edge of the Bragg peak. This increase was closely followed by a decrease in the relative detector sensitivity (Srel = Dgel/Ddiode), indicating that the response of the polymer gel detector was dependent on LET. The relative sensitivity was 0.8 at the Bragg peak, and reached its minimum value at the end of the proton range. No significant effects in the detector response were observed for LET < 4.9 keV microm(-1), thus indicating that the behaviour of the polymer gel dosimeter would not be altered for the range of LET values expected in the case of photons or electrons in a clinical range of energies.

          Related collections

          Author and article information

          Journal
          Phys Med Biol
          Physics in medicine and biology
          0031-9155
          0031-9155
          Sep 07 2004
          : 49
          : 17
          Affiliations
          [1 ] Department of Medical Radiation Physics, Lund University, Malmö University Hospital, SE-205 02, Malmö, Sweden. Helen.Gustavssson@rfa.mas.lu.se
          Article
          10.1088/0031-9155/49/17/002
          15470909
          86755ee2-432a-4953-aa5c-ab1ad5811a7c
          History

          Comments

          Comment on this article