54
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Indian Academy of Cytologists National Guidelines for Cytopathology Laboratories for Handling Suspected and Positive COVID-19 (SARS-CoV-2) Patient Samples

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          COVID-19, caused by the SARS-CoV-2 virus, has been declared a pandemic by the World Health Organization. This scenario has impacted the way we practice cytopathology. Cytology laboratories receive fresh and potentially infectious biological samples including those from the respiratory tract, from COVID-19 positive or suspected patients. Hence, the Indian Academy of Cytologists thought it necessary and fit to bring forth appropriate guidelines starting from transportation, receipt, processing, and reporting of samples in the COVID-19 era. The guidelines are prepared with the aim of safeguarding and protecting the health care personnel including laboratory staff, trainees and cytopathologists by minimizing exposure to COVID-19 so that they remain safe, in order to able to provide a continuous service. We hope that these national guidelines will be implemented across all cytopathology laboratories effectively.

          Related collections

          Most cited references3

          • Record: found
          • Abstract: found
          • Article: not found

          Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1

          To the Editor: A novel human coronavirus that is now named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (formerly called HCoV-19) emerged in Wuhan, China, in late 2019 and is now causing a pandemic. 1 We analyzed the aerosol and surface stability of SARS-CoV-2 and compared it with SARS-CoV-1, the most closely related human coronavirus. 2 We evaluated the stability of SARS-CoV-2 and SARS-CoV-1 in aerosols and on various surfaces and estimated their decay rates using a Bayesian regression model (see the Methods section in the Supplementary Appendix, available with the full text of this letter at NEJM.org). SARS-CoV-2 nCoV-WA1-2020 (MN985325.1) and SARS-CoV-1 Tor2 (AY274119.3) were the strains used. Aerosols (<5 μm) containing SARS-CoV-2 (105.25 50% tissue-culture infectious dose [TCID50] per milliliter) or SARS-CoV-1 (106.75-7.00 TCID50 per milliliter) were generated with the use of a three-jet Collison nebulizer and fed into a Goldberg drum to create an aerosolized environment. The inoculum resulted in cycle-threshold values between 20 and 22, similar to those observed in samples obtained from the upper and lower respiratory tract in humans. Our data consisted of 10 experimental conditions involving two viruses (SARS-CoV-2 and SARS-CoV-1) in five environmental conditions (aerosols, plastic, stainless steel, copper, and cardboard). All experimental measurements are reported as means across three replicates. SARS-CoV-2 remained viable in aerosols throughout the duration of our experiment (3 hours), with a reduction in infectious titer from 103.5 to 102.7 TCID50 per liter of air. This reduction was similar to that observed with SARS-CoV-1, from 104.3 to 103.5 TCID50 per milliliter (Figure 1A). SARS-CoV-2 was more stable on plastic and stainless steel than on copper and cardboard, and viable virus was detected up to 72 hours after application to these surfaces (Figure 1A), although the virus titer was greatly reduced (from 103.7 to 100.6 TCID50 per milliliter of medium after 72 hours on plastic and from 103.7 to 100.6 TCID50 per milliliter after 48 hours on stainless steel). The stability kinetics of SARS-CoV-1 were similar (from 103.4 to 100.7 TCID50 per milliliter after 72 hours on plastic and from 103.6 to 100.6 TCID50 per milliliter after 48 hours on stainless steel). On copper, no viable SARS-CoV-2 was measured after 4 hours and no viable SARS-CoV-1 was measured after 8 hours. On cardboard, no viable SARS-CoV-2 was measured after 24 hours and no viable SARS-CoV-1 was measured after 8 hours (Figure 1A). Both viruses had an exponential decay in virus titer across all experimental conditions, as indicated by a linear decrease in the log10TCID50 per liter of air or milliliter of medium over time (Figure 1B). The half-lives of SARS-CoV-2 and SARS-CoV-1 were similar in aerosols, with median estimates of approximately 1.1 to 1.2 hours and 95% credible intervals of 0.64 to 2.64 for SARS-CoV-2 and 0.78 to 2.43 for SARS-CoV-1 (Figure 1C, and Table S1 in the Supplementary Appendix). The half-lives of the two viruses were also similar on copper. On cardboard, the half-life of SARS-CoV-2 was longer than that of SARS-CoV-1. The longest viability of both viruses was on stainless steel and plastic; the estimated median half-life of SARS-CoV-2 was approximately 5.6 hours on stainless steel and 6.8 hours on plastic (Figure 1C). Estimated differences in the half-lives of the two viruses were small except for those on cardboard (Figure 1C). Individual replicate data were noticeably “noisier” (i.e., there was more variation in the experiment, resulting in a larger standard error) for cardboard than for other surfaces (Fig. S1 through S5), so we advise caution in interpreting this result. We found that the stability of SARS-CoV-2 was similar to that of SARS-CoV-1 under the experimental circumstances tested. This indicates that differences in the epidemiologic characteristics of these viruses probably arise from other factors, including high viral loads in the upper respiratory tract and the potential for persons infected with SARS-CoV-2 to shed and transmit the virus while asymptomatic. 3,4 Our results indicate that aerosol and fomite transmission of SARS-CoV-2 is plausible, since the virus can remain viable and infectious in aerosols for hours and on surfaces up to days (depending on the inoculum shed). These findings echo those with SARS-CoV-1, in which these forms of transmission were associated with nosocomial spread and super-spreading events, 5 and they provide information for pandemic mitigation efforts.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The COVID-19 pandemic: Implications for the cytology laboratory

            The coronavirus disease 2019 (COVID-19) is a pandemic with the SARS-CoV-2 virus. The infection has predominantly respiratory transmission and is transmitted through large droplets or aerosols, and less commonly by contact with infected surfaces or fomites. The alarming spread of the infection and the severe clinical disease that it may cause, have led to the widespread institution of social distancing measures. Due to repeated exposure to potentially infectious patients and specimens, healthcare and laboratory personnel are particularly susceptible to contract COVID-19. This review paper provides an assessment of the current state of knowledge about the disease and its pathology, and the potential presence of the virus in cytology specimens. It also discusses the measures that cytology laboratories can take to function during the pandemic, and minimize the risk to their personnel, trainees and pathologists. In addition, it explores potential means to continue to educate trainees during the COVID-19 pandemic.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Practical laboratory considerations amidst the COVID-19 outbreak: early experience from Singapore

              The coronavirus disease 2019 (COVID-19) is a zoonotic viral infection originating from Wuhan, China in December 2019. The World Health Organization has classified this pandemic as a global health emergency due to its virulent nature of transmission, which may lead to acute respiratory distress syndrome. Singapore’s health ministry has responded with enhanced surveillance of COVID-19 for all suspected pneumonia cases, further increasing the volume of testing via real-time reverse transcription PCR, as well as samples necessitating stringent infectious control. Collectively, this has implications on the total testing process, laboratory operations and its personnel due to biosafety concerns. Turnaround time for routine testing may also be affected. The aim of this article is to present our tertiary institution’s early experience with managing this emerging crisis and offer practical considerations for the preanalytical, analytical and postanalytical phases of laboratory testing in this cohort of patients.
                Bookmark

                Author and article information

                Journal
                J Cytol
                J Cytol
                JCytol
                Journal of Cytology
                Wolters Kluwer - Medknow (India )
                0970-9371
                0974-5165
                Apr-Jun 2020
                23 April 2020
                : 37
                : 2
                : 67-71
                Affiliations
                [1]Indian Academy of Cytologists, India
                Author notes
                Address for correspondence: Dr. Radhika Srinivasan, Secretary, Indian Academy of Cytologists. E-mail: secty.iac@ 123456gmail.com ; drsradhika@ 123456gmail.com
                Article
                JCytol-37-67
                10.4103/JOC.JOC_44_20
                7315918
                86ef5ed8-021b-4373-9971-baae27ebb7b6
                Copyright: © 2020 Journal of Cytology

                This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

                History
                : 08 April 2020
                : 08 April 2020
                Categories
                Review Article

                Pathology
                covid-19,cytology,cytopathology,guidelines,sars-cov-2
                Pathology
                covid-19, cytology, cytopathology, guidelines, sars-cov-2

                Comments

                Comment on this article