      Should Air Bubble Detectors Be Used to Quantify Microbubble Activity during Cardiopulmonary Bypass?

      Read this article at

      ScienceOpenPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Air bubble detectors (ABDs) are utilized during cardiopulmonary bypass (CPB) to protect against massive air embolism. Stockert (Munich, Germany) ABD quantify microbubbles >300 μm; however, their reliability has not been reported. The aim of this study was to assess the reliability of the microbubble data from the ABD with the SIII and S5 heart-lung machines. Microbubble counts from the ABD with the SIII (SIII ABD) and S5 (S5 ABD) were measured simultaneously with the emboli detection and classification (EDAC) quantifier in 12 CPB procedures using two EDAC detectors and two ABDs in series in the arterial line. Reliability was assessed by the Spearman correlation co-efficient (r) between measurements for each detector type, and between each ABD and EDAC detector for counts >300 μm. No correlation was found between the SIII ABD (r = .008, p = .793). A weak negative correlation was found with the S5 ABD (r = -.16, p < .001). A strong correlation was found between the EDAC detectors (SIII; r = .958, p < .001), (S5; r = .908, p < .001). With counts >300 μm, the SIII ABDs showed a correlation of small-medium effect size between EDAC detectors and ABD1 (r = .286, p < .001 [EDAC1], r = .347, p < .001 [EDAC2]). There was no correlation found between ABD2 and either EDAC detector (r = .003, p = .925 (EDAC1), r = .003, p = .929 [EDAC2]). A correlation between EDAC and the S5 ABD, was not able to be determined due to the low bubble count detected by the EDAC >300 μm. Both SIII ABD and S5 ABD were found to be unreliable for quantification of microbubble activity during CPB in comparison with the EDAC. These results highlight the importance of ensuring that data included in the CPB report is accurate and clinically relevant, and suggests that microbubble counts from devices such as the SIII ABD and S5 ABD should not be reported.

          Related collections

          Author and article information

          Journal
          J Extra Corpor Technol
          The journal of extra-corporeal technology
          0022-1058
          0022-1058
          Sep 2015
          : 47
          : 3
          Affiliations
          [1 ] Cardiac Surgery Research and Perfusion, Flinders Medical Centre, Bedford Park, South Australia ; Flinders University, Bedford Park, South Australia.
          [2 ] Cardiac Surgery Research and Perfusion, Flinders Medical Centre, Bedford Park, South Australia.
          Article
          4631215
          26543252
          872ca92a-38ef-4775-a8a5-71773443735c
          History

          embolism,cardiopulmonary bypass (CPB),microemboli,equipment

          Comments

          Comment on this article