      Design of 2D Sparse Array Transducers for Anomaly Detection in Medical Phantoms

      research-article
      * , ,
      Sensors (Basel, Switzerland)
      MDPI
      sparse array, ultrasonic transducer, particle detection

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Aperiodic sparse 2D ultrasonic array configurations, including random array, log spiral array, and sunflower array, have been considered for their potential as conformable transducers able to image within a focal range of 30–80 mm, at an operating frequency of 2 MHz. Optimisation of the imaging performance of potential array patterns has been undertaken based on their simulated far field directivity functions. Two evaluation criteria, peak sidelobe level (PSL) and integrated sidelobe ratio (ISLR), are used to access the performance of each array configuration. Subsequently, a log spiral array pattern with −19.33 dB PSL and 2.71 dB ISLR has been selected as the overall optimal design. Two prototype transducers with the selected log spiral array pattern have been fabricated and characterised, one using a fibre composite element composite array transducer (CECAT) structure, the other using a conventional 1–3 composite (C1–3) structure. The CECAT device demonstrates improved coupling coefficient (0.64 to 0.59), reduced mechanical cross-talk between neighbouring array elements (by 10 dB) and improved operational bandwidth (by 16.5%), while the C1–3 device performs better in terms of sensitivity (~50%). Image processing algorithms, such as Hough transform and morphological opening, have been implemented to automatically detect and dimension particles located within a fluid-filled tube structure, in a variety of experimental scenarios, including bespoke phantoms using tissue mimicking material. Experiments using the fabricated CECAT log spiral 2D array transducer demonstrated that this algorithmic approach was able to detect the walls of the tube structure and stationary anomalies within the tube with a precision of ~0.1 mm.

          Related collections

          Most cited references31

          • Record: found
          • Abstract: not found
          • Article: not found

          Minimum-redundancy linear arrays

          A. Moffet (1968)
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Post-processing of the full matrix of ultrasonic transmit–receive array data for non-destructive evaluation

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              PZT-epoxy piezoelectric transducers: A simplified fabrication procedure

                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                19 September 2020
                September 2020
                : 20
                : 18
                : 5370
                Affiliations
                Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1XW, UK; a.gachagan@ 123456strath.ac.uk (A.G.); paul.murray@ 123456strath.ac.uk (P.M.)
                Author notes
                Article
                sensors-20-05370
                10.3390/s20185370
                7570994
                32961726
                87653745-480c-480a-89bd-260f2ad8cdbd
                © 2020 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 30 July 2020
                : 17 September 2020
                Categories
                Article

                Biomedical engineering
                sparse array,ultrasonic transducer,particle detection
                Biomedical engineering
                sparse array, ultrasonic transducer, particle detection

                Comments

                Comment on this article