27
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Multiplex electrochemical origami immunodevice based on cuboid silver-paper electrode and metal ions tagged nanoporous silver-chitosan.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A 3D microfluidic electrochemical origami immunodevice (denoted as µ-ECOI in this work) for sensitive detection of tumor markers was designed. High sensitivity was achieved by using novel cuboid silver modified paper working electrode (CS-PWE) as sensor platform and different metal ions-coated nanoporous silver-chitosan (NSC) as labels. The CS-PWE was fabricated through a seed-mediated growth approach and served as a promising platform for antibodies attachment. The metal ions could be detected directly through square wave voltammetry without metal preconcentration, and each biorecognition event produced a distinct voltammetric peak, whose position and size reflected the identity and amount of the corresponding antigen. The large number of metal ions loading on the NSC greatly amplified the detection signals, and the good biocompatibility of CS-PWE retained good stability for the sandwich-type immunoassay. Using cancer antigen 125 (CA125) and carcinoma antigen 199 (CA199) as model analytes, the simultaneous multiplex immunoassay showed linear ranges of over 4 orders of magnitude with the detection limits down to 0.02 and 0.04 mU mL(-1), respectively. Moreover, this strategy accurately detected the concentrations of CA125 and CA199 in human serum samples. The detection limits of CA125 and CA199 were 0.08 and 0.10 mU mL(-1), respectively. This facile biosensing µ-ECOI exhibited high sensitivity and specificity with excellent stability, reproducibility, and accuracy, indicating its wide range of potential applications in point-of-care testing.

          Related collections

          Author and article information

          Journal
          Biosens Bioelectron
          Biosensors & bioelectronics
          1873-4235
          0956-5663
          Jun 15 2014
          : 56
          Affiliations
          [1 ] Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
          [2 ] Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, School of Material Science and Engineering, University of Jinan, Jinan 250022, PR China.
          [3 ] Cancer Research Center, Shandong Tumor Hospital, Jinan 250117, PR China.
          [4 ] Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China. Electronic address: ujn.yujh@gmail.com.
          Article
          S0956-5663(14)00014-1
          10.1016/j.bios.2014.01.011
          24487104
          87b84b24-04d9-4636-8c9e-3055fe034aa8
          Copyright © 2014 Elsevier B.V. All rights reserved.
          History

          Cuboid silver-paper electrode,Electrochemical immunoassay,Microfluidic origami device,Point-of-care testing

          Comments

          Comment on this article