      Sensing leg movement enhances wearable monitoring of energy expenditure

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Physical inactivity is the fourth leading cause of global mortality. Health organizations have requested a tool to objectively measure physical activity. Respirometry and doubly labeled water accurately estimate energy expenditure, but are infeasible for everyday use. Smartwatches are portable, but have significant errors. Existing wearable methods poorly estimate time-varying activity, which comprises 40% of daily steps. Here, we present a Wearable System that estimates metabolic energy expenditure in real-time during common steady-state and time-varying activities with substantially lower error than state-of-the-art methods. We perform experiments to select sensors, collect training data, and validate the Wearable System with new subjects and new conditions for walking, running, stair climbing, and biking. The Wearable System uses inertial measurement units worn on the shank and thigh as they distinguish lower-limb activity better than wrist or trunk kinematics and converge more quickly than physiological signals. When evaluated with a diverse group of new subjects, the Wearable System has a cumulative error of 13% across common activities, significantly less than 42% for a smartwatch and 44% for an activity-specific smartwatch. This approach enables accurate physical activity monitoring which could enable new energy balance systems for weight management or large-scale activity monitoring.

          Abstract

          Current methods to estimate energy expenditure are either infeasible for everyday use or associated with significant errors. Here the authors present a Wearable System using inertial measurement units worn on the shank and thigh that estimates metabolic energy expenditure in real-time during common steady-state and time-varying activities.

          Related collections

          Most cited references46

          • Record: found
          • Abstract: found
          • Article: not found

          OpenSim: open-source software to create and analyze dynamic simulations of movement.

          Dynamic simulations of movement allow one to study neuromuscular coordination, analyze athletic performance, and estimate internal loading of the musculoskeletal system. Simulations can also be used to identify the sources of pathological movement and establish a scientific basis for treatment planning. We have developed a freely available, open-source software system (OpenSim) that lets users develop models of musculoskeletal structures and create dynamic simulations of a wide variety of movements. We are using this system to simulate the dynamics of individuals with pathological gait and to explore the biomechanical effects of treatments. OpenSim provides a platform on which the biomechanics community can build a library of simulations that can be exchanged, tested, analyzed, and improved through a multi-institutional collaboration. Developing software that enables a concerted effort from many investigators poses technical and sociological challenges. Meeting those challenges will accelerate the discovery of principles that govern movement control and improve treatments for individuals with movement pathologies.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review

            Background Accurate assessment is required to assess current and changing physical activity levels, and to evaluate the effectiveness of interventions designed to increase activity levels. This study systematically reviewed the literature to determine the extent of agreement between subjectively (self-report e.g. questionnaire, diary) and objectively (directly measured; e.g. accelerometry, doubly labeled water) assessed physical activity in adults. Methods Eight electronic databases were searched to identify observational and experimental studies of adult populations. Searching identified 4,463 potential articles. Initial screening found that 293 examined the relationship between self-reported and directly measured physical activity and met the eligibility criteria. Data abstraction was completed for 187 articles, which described comparable data and/or comparisons, while 76 articles lacked comparable data or comparisons, and a further 30 did not meet the review's eligibility requirements. A risk of bias assessment was conducted for all articles from which data was abstracted. Results Correlations between self-report and direct measures were generally low-to-moderate and ranged from -0.71 to 0.96. No clear pattern emerged for the mean differences between self-report and direct measures of physical activity. Trends differed by measure of physical activity employed, level of physical activity measured, and the gender of participants. Results of the risk of bias assessment indicated that 38% of the studies had lower quality scores. Conclusion The findings suggest that the measurement method may have a significant impact on the observed levels of physical activity. Self-report measures of physical activity were both higher and lower than directly measured levels of physical activity, which poses a problem for both reliance on self-report measures and for attempts to correct for self-report – direct measure differences. This review reveals the need for valid, accurate and reliable measures of physical activity in evaluating current and changing physical activity levels, physical activity interventions, and the relationships between physical activity and health outcomes.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A new predictive equation for resting energy expenditure in healthy individuals.

              A predictive equation for resting energy expenditure (REE) was derived from data from 498 healthy subjects, including females (n = 247) and males (n = 251), aged 19-78 y (45 +/- 14 y, mean +/- SD). Normal-weight (n = 264) and obese (n = 234) individuals were studied and REE was measured by indirect calorimetry. Multiple-regression analyses were employed to drive relationships between REE and weight, height, and age for both men and women (R2 = 0.71): REE = 9.99 x weight + 6.25 x height - 4.92 x age + 166 x sex (males, 1; females, 0) - 161. Simplification of this formula and separation by sex did not affect its predictive value: REE (males) = 10 x weight (kg) + 6.25 x height (cm) - 5 x age (y) + 5; REE (females) = 10 x weight (kg) + 6.25 x height (cm) - 5 x age (y) - 161. The inclusion of relative body weight and body-weight distribution did not significantly improve the predictive value of these equations. The Harris-Benedict Equations derived in 1919 overestimated measured REE by 5% (p less than 0.01). Fat-free mass (FFM) was the best single predictor of REE (R2 = 0.64): REE = 19.7 x FFM + 413. Weight also was closely correlated with REE (R2 = 0.56): REE = 15.1 x weight + 371.
                Bookmark

                Author and article information

                Contributors
                patslade@stanford.edu
                Journal
                Nat Commun
                Nat Commun
                Nature Communications
                Nature Publishing Group UK (London )
                2041-1723
                13 July 2021
                13 July 2021
                2021
                : 12
                : 4312
                Affiliations
                [1 ]GRID grid.168010.e, ISNI 0000000419368956, Department of Mechanical Engineering, , Stanford University, ; Stanford, CA USA
                [2 ]GRID grid.168010.e, ISNI 0000000419368956, Department of Aeronautics and Astronautics, , Stanford University, ; Stanford, CA USA
                [3 ]GRID grid.168010.e, ISNI 0000000419368956, Department of Bioengineering, , Stanford University, ; Stanford, CA USA
                Author information
                http://orcid.org/0000-0001-9302-3911
                http://orcid.org/0000-0002-7238-9663
                Article
                24173
                10.1038/s41467-021-24173-x
                8277831
                34257310
                88691721-f8ce-44dd-a263-b0981a6ef3b8
                © The Author(s) 2021

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 21 December 2020
                : 7 June 2021
                Funding
                Funded by: FundRef https://doi.org/10.13039/100000001, National Science Foundation (NSF);
                Award ID: DGE-1656518
                Award Recipient :
                Categories
                Article
                Custom metadata
                © The Author(s) 2021

                Uncategorized
                sensors and probes,biotechnology,weight management,translational research,biomedical engineering

                Comments

                Comment on this article