46
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      A Review on Biodentine, a Contemporary Dentine Replacement and Repair Material

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Biodentine is a calcium-silicate based material that has drawn attention in recent years and has been advocated to be used in various clinical applications, such as root perforations, apexification, resorptions, retrograde fillings, pulp capping procedures, and dentine replacement. There has been considerable research performed on this material since its launching; however, there is scarce number of review articles that collates information and data obtained from these studies. Therefore, this review article was prepared to provide the reader with a general picture regarding the findings about various characteristics of the material. The results of a PubMed search were classified and presented along with some critical comments where necessary. The review initially focuses on various physical properties of the material with subheadings and continues with biocompatibility. Another section includes the review of studies on Biodentine as a vital pulp treatment material and the article is finalized with the summary of some case reports where the material has been used.

          Related collections

          Most cited references50

          • Record: found
          • Abstract: found
          • Article: not found

          Investigation of the hydration and bioactivity of radiopacified tricalcium silicate cement, Biodentine and MTA Angelus.

          Novel root-end filling materials are composed of tricalcium silicate (TCS) and radiopacifier as opposed to the traditional mineral trioxide aggregate (MTA) which is made up of clinker derived from Portland cement and bismuth oxide. The aim of this research was to characterize and investigate the hydration of a tricalcium silicate-based proprietary brand cement (Biodentine™) and a laboratory manufactured cement made with a mixture of tricalcium silicate and zirconium oxide (TCS-20-Z) and compare their properties to MTA Angelus™. The materials investigated included a cement containing 80% of TCS and 20% zirconium oxide (TCS-20-Z), Biodentine™ and MTA Angelus™. The specific surface area and the particle size distribution of the un-hydrated cements and zirconium oxide were investigated using a gas adsorption method and scanning electron microscopy. Un-hydrated cements and set materials were tested for mineralogy and microstructure, assessment of bioactivity and hydration. Scanning electron microscopy, X-ray energy dispersive analysis, X-ray fluorescence spectroscopy, X-ray diffraction, Rietveld refined X-ray diffraction and calorimetry were employed. The radiopacity of the materials was investigated using ISO 6876 methods. The un-hydrated cements were composed of tricalcium silicate and a radiopacifier phase; zirconium oxide for both Biodentine™ and TCS-20-Z whereas bismuth oxide for MTA Angelus™. In addition Biodentine™ contained calcium carbonate particles and MTA Angelus™ exhibited the presence of dicalcium silicate, tricalcium aluminate, calcium, aluminum and silicon oxides. TCS and MTA Angelus™ exhibited similar specific surface area while Biodentine™ had a greater specific surface area. The cements hydrated and produced some hydrates located either as reaction rim around the tricalcium silicate grain or in between the grains at the expense of volume containing the water initially present in the mixture. The rate of reaction of tricalcium calcium silicate was higher for Biodentine™ than for TCS-20-Z owing to its optimized particle size distribution, the presence of CaCO₃ and the use of CaCl₂. Tricalcium calcium silicate in MTA hydrated even more slowly than TCS-20-Z as evident from the size of reaction rim representative of calcium silicate hydrate (C-S-H) around tricalcium silicate grains and the calorimetry measurements. On the other hand, calcium oxide contained in MTA Angelus™ hydrated very fast inducing an intense exothermic reaction. Calcium hydroxide was produced as a by-product of reaction in all hydrated cements but in greater quantities in MTA due to the hydration of calcium oxide. This lead to less dense microstructure than the one observed for both Biodentine™ and TCS-20-Z. All the materials were bioactive and allowed the deposition of hydroxyapatite on the cement surface in the presence of simulated body fluid and the radiopacity was greater than 3mm aluminum thickness. All the cement pastes tested were composed mainly of tricalcium silicate and a radiopacifier. The laboratory manufactured cement contained no other additives. Biodentine™ included calcium carbonate which together with the additives in the mixing liquid resulted in a material with enhanced chemical properties relative to TCS-20-Z prototype cement. On the other hand MTA Angelus™ displayed the presence of calcium, aluminum and silicon oxides in the un-hydrated powder. These phases are normally associated with the raw materials indicating that the clinker of MTA Angelus™ is incompletely sintered leading to a potential important variability in its mineralogy depending on the sintering conditions. As a consequence, the amount of tricalcium silicate is less than in the two other cements leading to a slower reaction rate and more porous microstructure. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Zirconia as a ceramic biomaterial.

            Zirconia ceramics have several advantages over other ceramic materials, due to the transformation toughening mechanisms operating in their microstructure that can give to components made out of them, very interesting mechanical properties. The research on the use of zirconia ceramics as biomaterials started about twenty years ago, and now zirconia (Y-YZP) is in clinical use in THR, but developments are in progress for application in other medical devices. Recent developments have concentrated on the chemistry of precursors, in forming and sintering processes, and on surface finish of components. Today's main applications of zirconia ceramics is in THR ball heads. This review takes into account the main results achieved up to now, and is focused on the role that microstructural characteristics play on the TZP ceramics behaviour in ball heads, namely mechanical properties and their stability, wear of the UHMWPE paired to TZP, and their influence on biocompatibility.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Investigation of the physical properties of tricalcium silicate cement-based root-end filling materials.

              Tricalcium silicate-based cements have been displayed as suitable root-end filling materials. The physical properties of prototype radiopacified tricalcium silicate cement, Bioaggregate and Biodentine were investigated. Intermediate restorative material was used as a control. The physical properties of a prototype zirconium oxide replaced tricalcium silicate cement and two proprietary cements composed of tricalcium silicate namely Bioaggregate and Biodentine were investigated. Intermediate restorative material (IRM) was used as a control. Radiopacity assessment was undertaken and expressed in thickness of aluminum. In addition the anti-washout resistance was investigated using a novel basket-drop method and the fluid uptake, sorption and solubility were investigated using a gravimetric method. The setting time was assessed using an indentation technique and compressive strength and micro-hardness of the test materials were investigated. All the testing was performed with the test materials immersed in Hank's balanced salt solution. All the materials tested had a radiopacity value higher than 3mm thickness of aluminum. IRM exhibited the highest radiopacity. Biodentine demonstrated a high washout, low fluid uptake and sorption values, low setting time and superior mechanical properties. The fluid uptake and setting time was the highest for Bioaggregate. The addition of admixtures to tricalcium silicate-based cements affects the physical properties of the materials. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
                Bookmark

                Author and article information

                Journal
                Biomed Res Int
                Biomed Res Int
                BMRI
                BioMed Research International
                Hindawi Publishing Corporation
                2314-6133
                2314-6141
                2014
                16 June 2014
                : 2014
                : 160951
                Affiliations
                1Department of Prosthodontics, Faculty of Dentistry, Yeditepe University, Bagdat Caddesi 238, Goztepe, 34728 Istanbul, Turkey
                2Department of Endodontics, Faculty of Dentistry, Yeditepe University, Bagdat Caddesi 238, Goztepe, 34728 Istanbul, Turkey
                Author notes

                Academic Editor: Xiupeng Wang

                Article
                10.1155/2014/160951
                4082844
                25025034
                88c22e28-4035-43d2-89dc-165ba16e7343
                Copyright © 2014 Özlem Malkondu et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 16 February 2014
                : 16 April 2014
                : 8 May 2014
                Categories
                Review Article

                Comments

                Comment on this article