      Electrical impedance measurements of cochlear structures using the four-electrode reflection-coefficient technique.

      1 , ,
      Hearing research
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In individuals with severe-to-profound hearing loss, cochlear implants (CIs) bypass normal inner ear function by applying electrical current directly into the cochlea, thereby stimulating surviving auditory nerve fibers. Although cochlear implants are able to restore some auditory sensation, they are far from providing normal hearing. It has been estimated that up to 75% of the current injected via a CI is shunted along scala tympani and is not available to stimulate auditory neurons. The path of the injected current and the consequent population of stimulated spiral ganglion cells are dependent upon the positions of the electrode contacts within the cochlea and the impedances of cochlear structures. However, characterization of the current path remains one of the most critical, yet least understood, aspects of cochlear implantation. In particular, the impedances of cochlear structures, including the modiolus, are either unknown or based upon estimates derived from circuit models. Impedance values for many cochlear structures have never been measured. By combining the hemicochlea preparation, a cochlea cut in half along its mid-modiolar plane, and the four-electrode reflection-coefficient technique, impedances can be measured for cochlear tissues in a cochlear cross section including the modiolus. Advantages and disadvantages of the method are discussed in detail and electrical impedance measurements obtained in the gerbil hemicochlea are presented. The resistivity values for the cochlear wall in Omegacm are, 528 (range: 432-708) for scala media 3rd turn, 502 (range: 421-616) for scala tympani 3rd turn and scala vestibuli 2nd turn, 627 (range: 531-759) for scala media 2nd turn, 434 (range: 353-555) for scala tympani 2nd turn and scala vestibuli basal turn, 434 (range: 373-514) for scala media basal turn, and 590 (range: 546-643) for scala tympani basal turn. The resistivity was 455Omegacm (range: 426-487) for the modiolus.

          Related collections

          Author and article information

          Journal
          Hear. Res.
          Hearing research
          Elsevier BV
          1878-5891
          0378-5955
          Jan 2010
          : 259
          : 1-2
          Affiliations
          [1 ] Department of Otolaryngology - Head and Neck Surgery, Northwestern University, Feinberg School of Medicine, Chicago, Illinois 60611-3008, USA.
          Article
          S0378-5955(09)00255-X
          10.1016/j.heares.2009.10.010
          19857561
          88ee06a9-bf44-4171-8a53-5dfd7867abe0
          History

          Comments

          Comment on this article