156
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      The Impact of Hemolysis on Cell-Free microRNA Biomarkers

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Cell-free microRNAs in plasma and serum have become a promising source of biomarkers for various diseases. Despite rapid progress in this field, there remains a lack of consensus regarding optimal quantification methods, reference genes, and quality control of samples. Recent studies have shown that hemolysis occurring during blood collection has substantial impact on the microRNA content in plasma/serum. To date, the impact of hemolysis has only been investigated for a limited number of microRNAs, mainly the red blood cell (RBC)-enriched miRs-16 and -451. In contrast, the effect of hemolysis on other microRNAs – in particular those proposed as biomarkers – has not been addressed. In this study we profiled the microRNA content of hemolyzed and non-hemolyzed plasma as well as RBCs to obtain a profile of microRNAs in the circulation affected or unaffected by hemolysis. Profiling by TaqMan Array Microfluidic Cards was used to compare three pairs of hemolyzed and non-hemolyzed plasma (with varying degrees of hemolysis) and one RBC sample. A total of 136 microRNAs were detectable in at least two of the samples, and of those 15 were at least twofold elevated in all three hemolyzed samples. This number increased to 88 microRNAs for the sample with the highest level of hemolysis, with all of these also detected in the RBC profile. Thus these microRNAs represent a large proportion of detectable microRNAs and those most likely to be affected by hemolysis. Several of the hemolysis-susceptible microRNAs (e.g., miRs-21, -106a, -92a, -17, -16) have also been previously proposed as plasma/serum biomarkers of disease, highlighting the importance of rigorous quality control of plasma/serum samples used for measurement of circulating microRNAs. As low-level hemolysis is a frequent occurrence during plasma/serum collection it is critical that this is taken into account in the measurement of any candidate circulating microRNA.

          Related collections

          Most cited references41

          • Record: found
          • Abstract: found
          • Article: not found

          Circulating microRNA in body fluid: a new potential biomarker for cancer diagnosis and prognosis.

          In the past several years, the importance of microRNA (miRNA) in cancer cells has been recognized. Proper control of miRNA expression is essential for maintaining a steady state of the cellular machinery. Recently, it was discovered that extracellular miRNAs circulate in the blood of both healthy and diseased patients, although ribonuclease is present in both plasma and serum. Most of the circulating miRNAs are included in lipid or lipoprotein complexes, such as apoptotic bodies, microvesicles, or exosomes, and are, therefore, highly stable. The existence of circulating miRNAs in the blood of cancer patients has raised the possibility that miRNAs may serve as a novel diagnostic marker. However, the secretory mechanism and biological function, as well as the meaning of the existence of extracellular miRNAs, remain largely unclear. In this review, we summarize the usefulness of circulating miRNA for cancer diagnosis, prognosis, and therapeutics. Furthermore, we propose a mechanism for the secretion and incorporation of miRNA into the cells. © 2010 Japanese Cancer Association.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Plasma microRNAs are promising novel biomarkers for early detection of colorectal cancer.

            MicroRNA (miRNA) opens up a new field for molecular diagnosis of cancer. However, the role of circulating miRNAs in plasma/serum in cancer diagnosis is not clear. The aim of this study was to investigate whether plasma miRNAs can be used as biomarkers for the early detection of colorectal carcinoma (CRC). We measured the levels of 12 miRNAs (miR-134, -146a, -17-3p, -181d, -191, -221, -222, -223, -25, -29a, -320a and -92a) in plasma samples from patients with advanced colorectal neoplasia (carcinomas and advanced adenomas) and healthy controls using real-time RT-PCR. We found that plasma miR-29a and miR-92a have significant diagnostic value for advanced neoplasia. MiR-29a yielded an AUC (the areas under the ROC curve) of 0.844 and miR-92a yielded an AUC of 0.838 in discriminating CRC from controls. More importantly, these 2 miRNAs also could discriminate advanced adenomas from controls and yielded an AUC of 0.769 for miR-29a and 0.749 for miR-92a. Combined ROC analyses using these 2 miRNAs revealed an elevated AUC of 0.883 with 83.0% sensitivity and 84.7% specificity in discriminating CRC, and AUC of 0.773 with 73.0% sensitivity and 79.7% specificity in discriminating advanced adenomas. Collectively, these data suggest that plasma miR-29a and miR-92a have strong potential as novel noninvasive biomarkers for early detection of CRC.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Haemolysis during Sample Preparation Alters microRNA Content of Plasma

              The presence of cell-free microRNAs (miRNAs) has been detected in a range of body fluids. The miRNA content of plasma/serum in particular has been proposed as a potential source of novel biomarkers for a number of diseases. Nevertheless, the quantification of miRNAs from plasma or serum is made difficult due to inefficient isolation and lack of consensus regarding the optimal reference miRNA. The effect of haemolysis on the quantification and normalisation of miRNAs in plasma has not been investigated in great detail. We found that levels of miR-16, a commonly used reference gene, showed little variation when measured in plasma samples from healthy volunteers or patients with malignant mesothelioma or coronary artery disease. Including samples with evidence of haemolysis led to variation in miR-16 levels and consequently decreased its ability to serve as a reference. The levels of miR-16 and miR-451, both present in significant levels in red blood cells, were proportional to the degree of haemolysis. Measurements of the level of these miRNAs in whole blood, plasma, red blood cells and peripheral blood mononuclear cells revealed that the miRNA content of red blood cells represents the major source of variation in miR-16 and miR-451 levels measured in plasma. Adding lysed red blood cells to non-haemolysed plasma allowed a cut-off level of free haemoglobin to be determined, below which miR-16 and miR-451 levels displayed little variation between individuals. In conclusion, increases in plasma miR-16 and miR-451 are caused by haemolysis. In the absence of haemolysis the levels of both miR-16 and miR-451 are sufficiently constant to serve as normalisers.
                Bookmark

                Author and article information

                Journal
                Front Genet
                Front Genet
                Front. Genet.
                Frontiers in Genetics
                Frontiers Media S.A.
                1664-8021
                24 May 2013
                2013
                : 4
                : 94
                Affiliations
                [1] 1Asbestos Diseases Research Institute, University of Sydney , Sydney, NSW, Australia
                [2] 2Cardiothoracic Surgical Unit, Royal Prince Alfred Hospital , Sydney, NSW, Australia
                [3] 3The Baird Institute, University of Sydney , Sydney, NSW, Australia
                Author notes

                Edited by: William Cho, Queen Elizabeth Hospital, Hong Kong

                Reviewed by: Terrence Chi-Kong Lau, City University of Hong Kong, Hong Kong; Hyouta Himeno, Hirosaki University, Japan; Polly Leung, The Hong Kong Polytechnic University, Hong Kong; RaffaEle A. Calogero, University of Torino, Italy; Venugopal Thayanithy, University of Minnesota, USA

                *Correspondence: Glen Reid, Asbestos Diseases Research Institute, University of Sydney, PO Box 3628, Rhodes, Sydney, NSW 2138, Australia. e-mail: glen.reid@ 123456sydney.edu.au
                Article
                10.3389/fgene.2013.00094
                3663194
                23745127
                88f30658-bacb-45f0-ab19-bbf9fe13f9c0
                Copyright © 2013 Kirschner, Edelman, Kao, Vallely, van Zandwijk and Reid.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in other forums, provided the original authors and source are credited and subject to any copyright notices concerning any third-party graphics etc.

                History
                : 14 March 2013
                : 07 May 2013
                Page count
                Figures: 5, Tables: 5, Equations: 0, References: 65, Pages: 13, Words: 9028
                Categories
                Genetics
                Original Research

                Genetics
                cell-free microrna,red blood cells,hemolysis,biomarker,quality control
                Genetics
                cell-free microrna, red blood cells, hemolysis, biomarker, quality control

                Comments

                Comment on this article