      A study to investigate the ability of subjects with chronic lung diseases to provide evidential breath samples using the Lion Intoxilyzer®6000 UK breath alcohol testing device

      , , ,
      Respiratory Medicine
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The Lion Intoximeter 3000 has been used for evidential breath testing in the U.K. for some years. Some individuals with lung diseases have difficulty in providing evidential breath samples using the device. This study describes an investigation that we have carried out on a newer instrument--the Lion Intoxilyzer 6000UK--which is now in use in the U.K. The study was designed to investigate the ability of subjects with a variety of lung diseases to provide evidential breath samples using this device. The 40 adult subjects investigated comprized 10 normal controls, 10 with asthma, 10 with chronic obstructive pulmonary disease (COPD) and 10 with restrictive lung disease. After baseline spirometry, subjects were given alcohol to drink, the quantity based upon body weight. After a gap of at least 20 min, subjects were asked to provide evidential breath samples in accordance with.the test procedure built into the Lion Intoxilyzer 6000UK. The results showed that two asthmatic subjects, four with COPD and three with restrictive lung disease failed to provide evidential breath samples even after four attempts. Despite the device requiring a minimum sample volume of 1.2 l, eight of the nine subjects who failed had a forced vital capacity (FVC) of more than 1.5 l. Seven of these nine subjects had a forced expiratory volume in 1 sec (FEV1) of less than 1.0 l. In conclusion, this study has shown that some subjects with lung diseases may have difficulty in providing evidential breath samples using the Lion Intoxilyzer 6000 UK.

          Related collections

          Author and article information

          Journal
          Respiratory Medicine
          Respiratory Medicine
          Elsevier BV
          09546111
          July 2000
          July 2000
          : 94
          : 7
          : 684-688
          Article
          10.1053/rmed.2000.0797
          10926340
          898723ea-0e79-45b1-8b0f-b0bbd83f32ef
          © 2000

          https://www.elsevier.com/tdm/userlicense/1.0/

          https://www.elsevier.com/open-access/userlicense/1.0/

          History

          Comments

          Comment on this article