          Abstract

          Objectives

          In this prospective preclinical study, we evaluated T1-weighted signal intensity in the deep cerebellar nuclei (CN) and globus pallidus (GP) up to 24 days after repeated administration of linear and macrocyclic gadolinium-based contrast agents (GBCAs) using homologous imaging and evaluation methods as in the recently published retrospective clinical studies. In a second part of the study, cerebrospinal fluid (CSF) spaces were evaluated for contrast enhancement by fluid-attenuated magnetic resonance imaging (MRI).

          Materials and Methods

          Sixty adult male Wistar-Han rats were randomly divided into a control and 5 GBCA groups (n = 10 per group). The administered GBCAs were gadodiamide, gadopentetate dimeglumine, and gadobenate dimeglumine (linear GBCAs) as well as gadobutrol and gadoterate meglumine (macrocyclic GBCAs) and saline (control). Over a period of 2 weeks, the animals received 10 intravenous injections at a dose of 2.5 mmol Gd/kg body weight, each on 5 consecutive days per week. Before GBCA administration, as well as 3 and 24 days after the last injection, a whole-brain MRI was performed using a standard T1-weighted 3-dimensional turbo spin echo sequence on a clinical 1.5 T scanner. The ratios of signal intensities in deep CN to pons (CN/Po) and GP to thalamus (GP/Th) were determined. For the evaluation of the CSF spaces, 18 additional rats were randomly divided into 6 groups (n = 3 per group) that received the same GBCAs as in the first part of the study. After MR cisternography for anatomical reference, a fluid-attenuated inversion recovery sequence was performed before and 1 minute after intravenous injection of a dose of 1 mmol Gd/kg body weight GBCA or saline.

          Results

          A significantly increased signal intensity ratio of CN/Po was observed 3 and 24 days after the last injection of gadodiamide and gadobenate dimeglumine. No significant changes were observed between the 2 time points. Gadopentetate dimeglumine injection led to a moderately elevated but statistically not significant CN/Po signal intensity ratio. No increased CN/Po signal intensity ratios were determined in the MRI scans of rats that received macrocyclic GBCAs gadobutrol and gadoterate meglumine or saline. The ratio of signal intensity in GP/Th was not elevated in any group injected with GBCAs or saline. Enhanced signal intensities of CSF spaces were observed in the postcontrast fluid-attenuated inversion recovery images of all animals receiving GBCAs but not for saline.

          Conclusions

          In this animal study in rats, increased signal intensity in the CN was found up to 24 days after multiple, extended doses of linear GBCAs. However, in contrast to clinical reports, the signal enhancement in the GP was not reproduced, demonstrating the limitations of this animal experiment. The elevated signal intensities remained persistent over the entire observation period. In contrast, no changes of signal intensities in either the CN or the GP were observed for macrocyclic GBCAs. However, all GBCAs investigated were able to pass the blood-CSF barrier in rats to a certain, not yet quantified extent.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          A new look at cerebrospinal fluid circulation

          According to the traditional understanding of cerebrospinal fluid (CSF) physiology, the majority of CSF is produced by the choroid plexus, circulates through the ventricles, the cisterns, and the subarachnoid space to be absorbed into the blood by the arachnoid villi. This review surveys key developments leading to the traditional concept. Challenging this concept are novel insights utilizing molecular and cellular biology as well as neuroimaging, which indicate that CSF physiology may be much more complex than previously believed. The CSF circulation comprises not only a directed flow of CSF, but in addition a pulsatile to and fro movement throughout the entire brain with local fluid exchange between blood, interstitial fluid, and CSF. Astrocytes, aquaporins, and other membrane transporters are key elements in brain water and CSF homeostasis. A continuous bidirectional fluid exchange at the blood brain barrier produces flow rates, which exceed the choroidal CSF production rate by far. The CSF circulation around blood vessels penetrating from the subarachnoid space into the Virchow Robin spaces provides both a drainage pathway for the clearance of waste molecules from the brain and a site for the interaction of the systemic immune system with that of the brain. Important physiological functions, for example the regeneration of the brain during sleep, may depend on CSF circulation.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent.

            To compare changes in signal intensity (SI) ratios of the dentate nucleus (DN) and the globus pallidus (GP) to those of other structures on unenhanced T1-weighted magnetic resonance (MR) images between linear and macrocyclic gadolinium-based contrast agents (GBCAs).
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              High Signal Intensity in Dentate Nucleus on Unenhanced T1-weighted MR Images: Association with Linear versus Macrocyclic Gadolinium Chelate Administration.

              To assess whether an association exists between hyperintensity in the dentate nucleus (DN) on unenhanced T1-weighted magnetic resonance (MR) images and previous administration of gadolinium-based contrast agents (GBCAs) that contain different types of gadolinium chelates.
                Bookmark

                Author and article information

                Journal
                Invest Radiol
                Invest Radiol
                RLI
                Investigative Radiology
                Lippincott Williams & Wilkins
                0020-9996
                1536-0210
                February 2016
                18 February 2016
                : 51
                : 2
                : 83-89
                Affiliations
                [1]From the *MR and CT Contrast Media Research, Bayer Healthcare; †Institute of Vegetative Physiology, Charité; and ‡Clinical Project Management, Bayer Healthcare, Berlin, Germany.
                Author notes
                Correspondence to: Hubertus Pietsch, PhD, Bayer Healthcare, MR and CT Contrast Media Research, Muellerstr 178, 13353 Berlin, Germany. E-mail: hubertus.pietsch@ 123456bayer.com .
                Article
                RLI50086 00002
                10.1097/RLI.0000000000000242
                4747981
                26606548
                898fa0bf-d4da-4920-a3f8-27713cff149f
                Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.

                History
                : 30 October 2015
                : 11 November 2015
                Categories
                Original Articles
                Custom metadata
                TRUE

                gbca,contrast agent, mri,gadolinium,pons,retention,animal experiment,cerebrospinal fluid

                Comments

                Comment on this article