      Neurosurgical craniotomy localization using a virtual reality planning system versus intraoperative image-guided navigation.

      International Journal of Computer Assisted Radiology and Surgery
      Adolescent, Adult, Aged, Brain Neoplasms, radiography, surgery, Child, Cohort Studies, Craniotomy, adverse effects, methods, Diagnostic Imaging, Female, Follow-Up Studies, Humans, Magnetic Resonance Angiography, Male, Middle Aged, Minimally Invasive Surgical Procedures, Monitoring, Intraoperative, Neuronavigation, instrumentation, Neurosurgical Procedures, Preoperative Care, Prospective Studies, Risk Assessment, Stereotaxic Techniques, Surgery, Computer-Assisted, Tomography, X-Ray Computed, Treatment Outcome, User-Computer Interface, Young Adult

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Accurate craniotomy placement is essential for frameless neuronavigation in minimally invasive neurosurgery. A craniotomy using virtual reality (VR) can be as accurate as neuronavigation. We prospectively enrolled 48 patients that underwent minimally invasive cranial procedures planned using VR, followed by neuronavigation. First, craniotomies were planned using VR derived measurements. Second, frameless neuronavigation was applied to define the craniotomy. The locations of these paired craniotomies were compared. A correctly placed craniotomy was defined as one that enabled the surgeon to totally remove the pathology without need to enlarge the craniotomy intraoperatively. Using VR, the size and the position of the craniotomy were measured correctly in 47 of 48 cases (98%). In 44 of 48 cases (92%), neuronavigation identified the craniotomy site correctly. In cases where neuronavigation failed, minimally invasive surgery was successfully completed using preoperative VR surgery planning. No statistically significant difference was found between craniotomy localization using VR surgery planning or standard frameless neuronavigation (p = 0.36). The craniotomy for minimally invasive neurosurgical procedures can be identified accurately using VR surgery planning or neuronavigation. In cases of neuronavigation failure, VR surgery planning serves as an effective backup system to perform a minimally invasive operation.

          Related collections

          Author and article information

          Comments

          Comment on this article