      Permanent His bundle pacing at the time of atrioventricular node ablation: A 3-dimensional mapping approach

      brief-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction Key Teaching Points • Permanent His bundle pacing offers an alternative method of cardiac resynchronization in the setting of multiple comorbidities, including renal failure. • The QRS morphology alone may not always clearly reflect loss of His capture when checking capture thresholds with a permanent His bundle lead. A multipolar catheter positioned at the His position would help discern an accurate His capture threshold. • An atrioventricular junction ablation can be safely performed without impacting the capture threshold of a newly implanted permanent His bundle lead with the aid of 3-dimensional mapping. Cardiac resynchronization therapy (CRT) has shown a significant clinical benefit over right ventricular pacing in patients with left ventricular dysfunction and a high ventricular pacing requirement. 1 Traditionally, CRT has relied on coronary sinus (CS) lead placement through the use of fluoroscopy and venography. Three-dimensional (3D) electroanatomic mapping has been used as an alternative technique for CS lead placement. 2 Recently, permanent His bundle pacing has emerged as another technique to achieve CRT via near physiologic activation of both ventricles through the native His-Purkinje system. We report a novel technique for permanent His bundle lead placement followed by atrioventricular (AV) junction ablation using 3D mapping. Case report An otherwise healthy 92-year-old man was admitted with respiratory distress and rapid atrial fibrillation. Despite aggressive attempts at rate and rhythm control, recurrent hemodynamically significant atrial fibrillation resulted in acute liver and kidney injury. A transthoracic echocardiogram showed an ejection fraction of 45%. The decision was made to pursue atrioventricular node ablation and pacemaker implantation. Owing to the patient’s advanced age, severe renal dysfunction, and ventricular dysfunction, permanent His bundle pacing, rather than biventricular pacing, was favored as a method to achieve cardiac resynchronization and avoid the use of intravenous contrast. We report a novel method for safe, accurate, and effective His bundle lead implantation using a 3D mapping system (NavX; St. Jude Medical, St. Paul, MN). A 4-mm ablation catheter was used via a femoral venous approach to create a 3D geometry of the superior and inferior venae cavae, right atrium, His bundle region, and CS (Figure 1). An octapolar catheter was used to map both proximal and distal His bundle recordings (yellow dots). Pacing with this catheter from a His bundle location, distal to where AV node ablation would routinely be performed, resulted in parahisian capture. Figure 1 Three dimensional map of the His cloud, final permanent His bundle lead position, and site of AV node ablation: 3D map showing final permanent His bundle lead location (white arrow). The yellow dots represent His points collected during electroanatomic mapping. The red dot represents the site of AV node ablation at a more proximal location relative to the His bundle lead. LAO = left anterior oblique; RAO = right anterior oblique. A preshaped sheath (C315 His; Medtronic, Inc, St. Paul, MN) was used to guide the active fixation pacing lead (3830 SelectSecure; Medtronic, Inc, St. Paul, MN) to a distal His bundle location under direct visualization with the 3D mapping system. Figure 2 shows the intracardiac recordings from the octapolar catheter during pacing from the permanent His bundle lead. Parahisian capture (solid red arrow) is shown at higher outputs with loss of His capture (curved red arrow) and retrograde His activation (dashed red arrows) at lower outputs despite a minimal change in QRS morphology (red circles). Though the change in QRS morphology is subtle, the increase in QRS duration reflects a change from parahisian to septal capture. The lead was secured at its final location (Figure 1, white arrow) with a parahisian capture threshold of 1.75 V at 1.0 ms and right ventricular septal capture threshold of 0.5 V at 1.0 ms. After connection to the pulse generator and pocket closure, radiofrequency catheter ablation of the AV node was performed at a location proximal to the His bundle lead (Figure 1, red dot). The parahisian capture threshold remained stable the following morning, and the patient was discharged home. He was unexpectedly readmitted 2 weeks later with acute respiratory failure secondary to health care–associated pneumonia. The pacemaker was functioning normally at this time. Owing to prior patient wishes regarding intubation and intensive care unit–level care, his family elected to pursue comfort care. The patient died owing to respiratory failure during the hospitalization. Figure 2 Intracardiac electrograms during permanent His bundle lead threshold testing: With decreasing outputs during threshold testing of the permanent His bundle lead, loss of his capture and retrograde His activation are shown on the octopolar mapping catheter (curved red arrows and dashed arrows). This is accompanied by a subtle change in QRS morphology, but a clear increase in QRS duration (red circles). Discussion To our knowledge, this is the first report of the use of 3D mapping to guide permanent His bundle lead implantation. His bundle pacing has emerged as an alternative technique to achieve electrical resynchronization.3, 4, 5 In this case, 3D mapping allowed lead placement at a location that resulted in His bundle capture without any compromise from AV node ablation. Further studies are needed with regard to the long-term efficacy and durability of this technique, as well as its potential to reduce procedure and fluoroscopy times.

          Related collections

          Most cited references4

          • Record: found
          • Abstract: found
          • Article: not found

          Biventricular pacing for atrioventricular block and systolic dysfunction.

          Right ventricular pacing restores an adequate heart rate in patients with atrioventricular block, but high percentages of right ventricular apical pacing may promote left ventricular systolic dysfunction. We evaluated whether biventricular pacing might reduce mortality, morbidity, and adverse left ventricular remodeling in such patients. We enrolled patients who had indications for pacing with atrioventricular block; New York Heart Association (NYHA) class I, II, or III heart failure; and a left ventricular ejection fraction of 50% or less. Patients received a cardiac-resynchronization pacemaker or implantable cardioverter-defibrillator (ICD) (the latter if the patient had an indication for defibrillation therapy) and were randomly assigned to standard right ventricular pacing or biventricular pacing. The primary outcome was the time to death from any cause, an urgent care visit for heart failure that required intravenous therapy, or a 15% or more increase in the left ventricular end-systolic volume index. Of 918 patients enrolled, 691 underwent randomization and were followed for an average of 37 months. The primary outcome occurred in 190 of 342 patients (55.6%) in the right-ventricular-pacing group, as compared with 160 of 349 (45.8%) in the biventricular-pacing group. Patients randomly assigned to biventricular pacing had a significantly lower incidence of the primary outcome over time than did those assigned to right ventricular pacing (hazard ratio, 0.74; 95% credible interval, 0.60 to 0.90); results were similar in the pacemaker and ICD groups. Left ventricular lead-related complications occurred in 6.4% of patients. Biventricular pacing was superior to conventional right ventricular pacing in patients with atrioventricular block and left ventricular systolic dysfunction with NYHA class I, II, or III heart failure. (Funded by Medtronic; BLOCK HF ClinicalTrials.gov number, NCT00267098.).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice.

            Right ventricular pacing (RVP) has been associated with heart failure and increased mortality. His-bundle pacing (HBP) is more physiological but requires a mapping catheter or a backup right ventricular lead and is technically challenging.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation.

              Direct His-bundle pacing (DHBP) produces synchronous ventricular depolarization and improved cardiac function relative to apical pacing. Although it has been performed transiently in the electrophysiology laboratory and persistently in open-chested canines, permanent DHBP in humans has not been achieved. A total of 18 patients aged 69+/-10 years who had a history of chronic atrial fibrillation, dilated cardiomyopathy, and normal activation (ie, QRS< or =120 ms) were screened for permanent DHBP using an electrophysiology catheter. In 14 patients, the His bundle could be reliably stimulated. Of these 14, permanent DHBP using a fixed screw-in lead was successful in 12 patients. Radiofrequency atrioventricular node ablation was performed in patients exhibiting a fast ventricular response. All patients received single-chamber rate-responsive pacemakers. Acute pacing thresholds were 2.4+/-1.0 V at a pulse duration of 0.5 ms. Lead complications included exit block requiring reoperative adjustment and gross lead dislodgment. Echocardiographic improvement in heart function was shown by reductions in the left ventricular end-diastolic dimension from 59+/-8 to 52+/-6 mm (P
                Bookmark

                Author and article information

                Contributors
                Journal
                HeartRhythm Case Rep
                HeartRhythm Case Rep
                HeartRhythm Case Reports
                Elsevier
                2214-0271
                24 April 2017
                June 2017
                24 April 2017
                : 3
                : 6
                : 323-325
                Affiliations
                [1]Division of Cardiology, Department of Medicine, Northwestern University, Feinberg School of Medicine, Chicago, Illinois
                Author notes
                [] Address reprint requests and correspondence: Dr Sukit Ringwala, Division of Cardiology, Department of Medicine, Northwestern University, Feinberg School of Medicine, 251 East Huron St, Feinberg 8-503, Chicago, IL 60611.Division of CardiologyDepartment of MedicineNorthwestern UniversityFeinberg School of Medicine251 East Huron St, Feinberg 8-503ChicagoIL60611 sukit.ringwala@ 123456northwestern.edu
                Article
                S2214-0271(17)30074-X
                10.1016/j.hrcr.2017.04.005
                5469314
                28649507
                8dfbc863-4b02-4189-81ea-21139b767457
                © 2017 Heart Rhythm Society. Published by Elsevier Inc.

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                Categories
                Image

                permanent his bundle pacing,cardiac resynchronization,av node ablation,three-dimensional mapping,atrial fibrillation

                Comments

                Comment on this article