      Predicting Hemodialysis Access Failure with Color Flow Doppler Ultrasound

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Color flow doppler ultrasound examination of the hemodialysis access was conducted in 2,792 hemodialysis patients to evaluate its value in predicting hemodialysis access failure. After baseline assessment of vascular access function with clinical and laboratory tests including color flow doppler evaluation these patients were followed for a minimal of 6 months or until graft failure occurred (defined as surgery or angioplasty intervention, or graft loss). The patient demographics and vascular accesses were typical of a standard hemodialysis patient population. On the day of the color flow doppler examination systolic and diastolic blood pressure, hematocrit, urea reduction ratio, dialysis blood flow, venous line pressure at a dialysis blood flow of 250 ml/min, and access recirculation rate were measured. At the conclusion of the study 23.5% of the patients had access failure. Case mix predictors for access failure were determined using the Cox Model. Case mix predictors of access failure were race, non-white was higher than white (p < 0.005), younger accesses had a higher risk than older accesses (p < 0.025), accesses with prior thrombosis had a higher risk of failure (p = 0.042), polytetrafluoroethylene (PTFE) grafts had a higher risk than native vein fistulae (p < 0.05), loop PTFE grafts had a higher risk than straight PTFE grafts (p < 0.025), and upper arm accesses had a higher risk than forearm accesses (p = 0.033). Most significant, however, was decreased access blood flow as measured by color flow doppler (p < 0.0001). The relative risk of graft failure increased 40% when the blood flow in the graft decreased to less than 500 ml/min and the relative risk doubled when the blood flow was less than 300 ml/min. This study has shown that color flow doppler evaluation, quantifying blood flow in a prosthetic graft, can identify those grafts at risk for failure. In contrast, color doppler volume flow in native AV fistulae could not predict fistula survival. This technique is noninvasive, painless, portable, and reproducible. We believe that preemptory repair of an anatomical abnormality in vascular access grafts with decreased blood flow may decrease patient inconvenience, associated morbidity, and associated costs.

          Related collections

          Most cited references1

          • Record: found
          • Abstract: not found
          • Article: not found

          The Achilles' heel of the hemodialysis patient

            Bookmark

            Author and article information

            Journal
            AJN
            Am J Nephrol
            10.1159/issn.0250-8095
            American Journal of Nephrology
            S. Karger AG
            0250-8095
            1421-9670
            1998
            August 1998
            05 June 1998
            : 18
            : 4
            : 296-304
            Affiliations
            Departments of Internal Medicine and Surgery, Ohio State University Hospital, Columbus, Ohio, and Fresenius Medical Care of North America, Lexington, Mass., USA
            Article
            13354 Am J Nephrol 1998;18:296–304
            10.1159/000013354
            9653833
            8fbf7a99-2eeb-490f-b612-5c8a29eec39c
            © 1998 S. Karger AG, Basel

            Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

            History
            Page count
            Figures: 3, Tables: 4, References: 35, Pages: 9
            Categories
            Clinical Study

            Cardiovascular Medicine,Nephrology
            Doppler ultrasound,Access clotting,Access blood flow,Hemodialysis access

            Comments

            Comment on this article