4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Effects of various electrode configurations on music perception, intonation and speaker gender identification.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Advances in speech coding strategies and electrode array designs for cochlear implants (CIs) predominantly aim at improving speech perception. Current efforts are also directed at transmitting appropriate cues of the fundamental frequency (F0) to the auditory nerve with respect to speech quality, prosody, and music perception. The aim of this study was to examine the effects of various electrode configurations and coding strategies on speech intonation identification, speaker gender identification, and music quality rating. In six MED-EL CI users electrodes were selectively deactivated in order to simulate different insertion depths and inter-electrode distances when using the high definition continuous interleaved sampling (HDCIS) and fine structure processing (FSP) speech coding strategies. Identification of intonation and speaker gender was determined and music quality rating was assessed. For intonation identification HDCIS was robust against the different electrode configurations, whereas fine structure processing showed significantly worse results when a short electrode depth was simulated. In contrast, speaker gender recognition was not affected by electrode configuration or speech coding strategy. Music quality rating was sensitive to electrode configuration. In conclusion, the three experiments revealed different outcomes, even though they all addressed the reception of F0 cues. Rapid changes in F0, as seen with intonation, were the most sensitive to electrode configurations and coding strategies. In contrast, electrode configurations and coding strategies did not show large effects when F0 information was available over a longer time period, as seen with speaker gender. Music quality relies on additional spectral cues other than F0, and was poorest when a shallow insertion was simulated.

          Related collections

          Author and article information

          Journal
          Cochlear Implants Int
          Cochlear implants international
          Maney Publishing
          1754-7628
          1467-0100
          Jan 2014
          : 15
          : 1
          Article
          cim157
          10.1179/1754762813Y.0000000037
          23684531
          8fdbd35b-bcf8-413e-acab-726fbcbec833
          History

          Cochlear implant,Prosody,Music quality,Inter-electrode distance,Insertion depth

          Comments

          Comment on this article