      U-Jacketing Applications of Fiber-Reinforced Polymers in Reinforced Concrete T-Beams against Shear—Tests and Design

      , ,
      Fibers
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The application of externally bonded fiber-reinforced polymer (EB-FRP) as shear transverse reinforcement applied in vulnerable reinforced concrete (RC) beams has been proved to be a promising strengthening technique. However, past studies revealed that the effectiveness of this method depends on how well the reinforcement is bonded to the concrete surface. Thus, although the application of EB-FRP wrapping around the perimeter of rectangular cross-sections leads to outstanding results, U-jacketing in shear-critical T-beams seems to undergo premature debonding failures resulting in significant reductions of the predictable strength. In this work, five shear-critical RC beams with T-shaped cross-section were constructed, strengthened and tested in four-point bending. Epoxy bonded carbon FRP (C-FRP) sheets were applied on the three sides and along the entire length of the shear-strengthened T-beams as external transverse reinforcement. Furthermore, the potential enhancement of the C-FRP sheets anchorage using bolted steel laminates has been examined. Test results indicated that although the C-FRP strengthened beams exhibited increased shear capacity, the brittle failure mode was not prevented due to the debonding of the FRP from the concrete surface. Nevertheless, the applied mechanical anchor of the C-FRP sheets delayed the debonding. Moreover, the design provisions of three different code standards (Greek Code of Interventions, Eurocode 8 and ACI Committee 440) concerning the shear capacity of T-shaped RC beams retrofitted with EB-FRP jackets or strips in U-jacketing configuration are investigated. The ability of these code standards to predict safe design estimations is checked against 165 test data from the current experimental project and data available in the literature.

          Related collections

          Most cited references7

          • Record: found
          • Abstract: not found
          • Article: not found

          Shear Strengthening of Reinforced Concrete Beams Using Epoxy-Bonded FRP Composites

          (1998)
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Shear strengthening of reinforced concrete beams using externally applied composite fabrics.

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Behavior of reinforced concrete T-beams strengthened in shear with carbon fiber-reinforced polymer-an experimental study

                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                Journal
                FIBECU
                Fibers
                Fibers
                MDPI AG
                2079-6439
                February 2020
                February 17 2020
                : 8
                : 2
                : 13
                Article
                10.3390/fib8020013
                91e186c2-39d0-4b5c-88bf-5f92b54d8316
                © 2020

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article