6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Comparison of postoperative higher-order aberrations and contrast sensitivity: tissue-saving versus conventional photorefractive keratectomy for low to moderate myopia.

      Journal of Cataract and Refractive Surgery
      Adult, Algorithms, Contrast Sensitivity, physiology, Corneal Wavefront Aberration, etiology, Female, Humans, Lasers, Excimer, therapeutic use, Male, Myopia, surgery, Patient Satisfaction, Photorefractive Keratectomy, methods, Postoperative Complications, Prospective Studies, Questionnaires, Visual Acuity, Young Adult

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To assess the efficacy, predictability, safety, contrast sensitivity, higher-order aberrations (HOAs), and patient satisfaction after tissue-saving photorefractive keratectomy (PRK) and conventional PRK. Department of Ophthalmology, Farabi Eye Hospital, Tehran Medical University, Tehran, Iran. Comparative case series. This prospective study evaluated eyes with low to moderate myopia that had PRK with a Technolas 217z excimer laser. Patients were randomly assigned to have surgery using a conventional algorithm (PlanoScan) or a tissue-saving algorithm (Zyoptix). Contrast sensitivity, HOAs, and patient satisfaction were analyzed preoperatively and 1, 3, and 6 months postoperatively. The conventional group comprised 42 eyes (21 patients) and the tissue-saving group, 62 eyes (31 patients). At 6 months, all eyes in both groups were within ±0.50 diopter of the attempted correction and had an uncorrected distance visual acuity of 20/25 or better. However, the tissue-saving group had a statistically significantly greater increase in the mean root mean square of total HOAs and more induced spherical aberration than the conventional group (P<.05). There was no significant difference between the 2 groups in mesopic or photopic contrast sensitivity. The level of satisfaction after surgery was the same in the 2 groups. Although the conventional and tissue-saving algorithms for PRK were both safe and effective in treating low to moderate myopia, tissue-saving PRK induced a greater increase in HOAs than conventional PRK; this may be because of the smaller blend zone of the tissue-saving algorithm. Contrast sensitivity and patient satisfaction were comparable between the 2 methods. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article