35
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Platelet function tests: a comparative review

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In physiological hemostasis a prompt recruitment of platelets on the vessel damage prevents the bleeding by the rapid formation of a platelet plug. Qualitative and/or quantitative platelet defects promote bleeding, whereas the high residual reactivity of platelets in patients on antiplatelet therapies moves forward thromboembolic complications. The biochemical mechanisms of the different phases of platelet activation – adhesion, shape change, release reaction, and aggregation – have been well delineated, whereas their complete translation into laboratory assays has not been so fulfilled. Laboratory tests of platelet function, such as bleeding time, light transmission platelet aggregation, lumiaggregometry, impedance aggregometry on whole blood, and platelet activation investigated by flow cytometry, are traditionally utilized for diagnosing hemostatic disorders and managing patients with platelet and hemostatic defects, but their use is still limited to specialized laboratories. To date, a point-of-care testing (POCT) dedicated to platelet function, using pertinent devices much simpler to use, has now become available (ie, PFA-100, VerifyNow System, Multiplate Electrode Aggregometry [MEA]). POCT includes new methodologies which may be used in critical clinical settings and also in general laboratories because they are rapid and easy to use, employing whole blood without the necessity of sample processing. Actually, these different platelet methodologies for the evaluation of inherited and acquired bleeding disorders and/or for monitoring antiplatelet therapies are spreading and the study of platelet function is strengthening. In this review, well-tried and innovative platelet function tests and their methodological features and clinical applications are considered.

          Related collections

          Most cited references163

          • Record: found
          • Abstract: not found
          • Article: not found

          Aggregation of blood platelets by adenosine diphosphate and its reversal.

          G V Born (1962)
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Consensus and future directions on the definition of high on-treatment platelet reactivity to adenosine diphosphate.

            The addition of clopidogrel to aspirin treatment reduces ischemic events in a wide range of patients with cardiovascular disease. However, recurrent ischemic event occurrence during dual antiplatelet therapy, including stent thrombosis, remains a major concern. Platelet function measurements during clopidogrel treatment demonstrated a variable and overall modest level of P2Y(12) inhibition. High on-treatment platelet reactivity to adenosine diphosphate (ADP) was observed in selected patients. Multiple studies have now demonstrated a clear association between high on-treatment platelet reactivity to ADP measured by multiple methods and adverse clinical event occurrence. However, the routine measurement of platelet reactivity has not been widely implemented and recommended in the guidelines. Reasons for the latter include: 1) a lack of consensus on the optimal method to quantify high on-treatment platelet reactivity and the cutoff value associated with clinical risk; and 2) limited data to support that alteration of therapy based on platelet function measurements actually improves outcomes. This review provides a consensus opinion on the definition of high on-treatment platelet reactivity to ADP based on various methods reported in the literature and proposes how this measurement may be used in the future care of patients. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of platelet function tests in predicting clinical outcome in patients undergoing coronary stent implantation.

              Context High on-treatment platelet reactivity is associated with atherothrombotic events following coronary stent implantation. Objective To evaluate the capability of multiple platelet function tests to predict clinical outcome. Design, Setting, and Patients Prospective, observational, single-center cohort study of 1069 consecutive patients taking clopidogrel undergoing elective coronary stent implantation between December 2005 and December 2007. On-treatment platelet reactivity was measured in parallel by light transmittance aggregometry, Verify Now P2Y12 and Platelet works assays, and the IMPACT-R and the platelet function analysis system (PFA-100) (with the Dade PFA collagen/adenosine diphosphate (ADP) cartridge and Innovance PFA P2Y). Cutoff values for high on-treatment platelet reactivity were established by receiver operating characteristic curve (ROC) analysis. Main Outcome Measurement The primary end point was defined as a composite of all-cause death, nonfatal acute myocardial infarction, stent thrombosis, and ischemic stroke. The primary safety end point included TIMI (Thrombolysis In Myocardial Infarction) criteria major and minor bleeding. Results Kaplan-Meier analysis demonstrated that at 1-year follow-up, the primary end point occurred more frequently in patients with high on-treatment platelet reactivity when assessed by light transmittance aggregometry (52 [11.7%; 95% confidence interval {CI}, 8.9%-15.0%] vs 36 [6.0%;95%CI, 4.2%-8.2%] P.001; n=1049),Verify Now (54 [13.3%; 95% CI, 10.2%-17.0%] vs 37 [5.7%; 95% CI, 4.1%-7.8%]P.001; n=1052), Platelet works (33 [12.6%; 95% CI, 8.8%-17.2%] vs 21 [6.1%;95% CI, 3.8%-9.2%] P=.005; n=606), and Innovance PFA P2Y (18 [12.2%; 95%CI; 7.4%-18.6%] vs 28 [6.3%; 95% CI, 4.3%-8.9%] P=.02; n=588). ROC-curve analysis demonstrated that light transmittance aggregometry (area under the curve[AUC], 0.63; 95% CI, 0.58-0.68), Verify Now (AUC, 0.62; 95% CI, 0.57-0.67), and Platelet works (AUC, 0.61; 95% CI, 0.53-0.69) had modest ability to discriminate between patients with and without primary end point at 1-year follow-up. The IMPACT-R(n=905) and the Siemens PFA Collagen/ADP (n=812) were unable to discriminate between patients with and without the primary end point at 1-year follow-up (all AUCs included 0.50 in the CI). None of the tests identified patients at risk for bleeding. Conclusions Of the platelet function tests assessed, light transmittance aggregometry,Verify Now, Platelet works, and Innovance PFA P2Y were significantly associated with the primary end point. However, the predictive accuracy of these 4 tests was only modest. None of the tests provided accurate prognostic information to identify patients at higher risk of bleeding following stent implantation. Trial Registration clinical trials.gov Identifier: NCT00352014 [corrected].
                Bookmark

                Author and article information

                Journal
                Vasc Health Risk Manag
                Vasc Health Risk Manag
                Vascular Health and Risk Management
                Vascular Health and Risk Management
                Dove Medical Press
                1176-6344
                1178-2048
                2015
                18 February 2015
                : 11
                : 133-148
                Affiliations
                [1 ]Department of Experimental and Clinical Medicine, Thrombosis Center, University of Florence, Florence, Italy
                [2 ]Department of Heart and Vessels, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
                Author notes
                Correspondence: Rita Paniccia, Department of Experimental and Clinical Medicine, Thrombosis Center, University of Florence, Viale Pieraccini, 19, 50134 Florence, Italy, Tel +39 055 7949 419, Fax +39 055 7949 929, Email rita.paniccia@ 123456unifi.it
                Article
                vhrm-11-133
                10.2147/VHRM.S44469
                4340464
                25733843
                9249e2f8-e86e-4658-9f49-1df80f3545c6
                © 2015 Paniccia et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License

                The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.

                History
                Categories
                Review

                Cardiovascular Medicine
                platelets,method,point-of-care testing,laboratory assessment,bleeding,thrombosis

                Comments