      Participants' Experiences of, and Views About, Daytime Use of a Day-and-Night Hybrid Closed-Loop System in Real Life Settings: Longitudinal Qualitative Study

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective: To explore individuals' experiences of daytime use of a day-and-night hybrid closed-loop system, their information and support needs, and their views about how future systems could be improved.

          Research Design and Methods: Twenty-four adults, adolescents, and parents were interviewed before using a hybrid day-and-night closed-loop system and 3 months later, data were analyzed thematically.

          Results: Participants praised the closed loop's ability to respond to high and low blood glucose in ways which extended beyond their own capabilities and to act as a safety net and mop up errors, such as when a mealtime bolus was forgotten or unplanned activity was undertaken. Participants also described feeling less burdened by diabetes as a consequence and more able to lead flexible, spontaneous lives. Contrary to their initial expectations, and after trust in the system had been established, most individuals wanted opportunities to collaborate with the closed loop to optimize its effectiveness. Such individuals expressed a need to communicate information, such as when routines changed or to indicate different intensities of physical activity. While individuals valued frequent contact with staff in the initial month of use, most felt that their long-term support needs would be no greater than when using an insulin pump.

          Conclusions: While participants reported substantial benefits to using the closed loop during the day, they also identified ways in which the technology could be refined and education and training tailored to optimize effective use. Our findings suggest that mainstreaming this technology will not necessarily lead to increased demands on clinical staff.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial

          Summary Background The achievement of glycaemic control remains challenging for patients with type 1 diabetes. We assessed the effectiveness of day-and-night hybrid closed-loop insulin delivery compared with sensor-augmented pump therapy in people with suboptimally controlled type 1 diabetes aged 6 years and older. Methods In this open-label, multicentre, multinational, single-period, parallel randomised controlled trial, participants were recruited from diabetes outpatient clinics at four hospitals in the UK and two centres in the USA. We randomly assigned participants with type 1 diabetes aged 6 years and older treated with insulin pump and with suboptimal glycaemic control (glycated haemoglobin [HbA1c] 7·5–10·0%) to receive either hybrid closed-loop therapy or sensor-augmented pump therapy over 12 weeks of free living. Training on study insulin pump and continuous glucose monitoring took place over a 4-week run-in period. Eligible subjects were randomly assigned using central randomisation software. Allocation to the two study groups was unblinded, and randomisation was stratified within centre by low (<8·5%) or high (≥8·5%) HbA1c. The primary endpoint was the proportion of time that glucose concentration was within the target range of 3·9–10·0 mmol/L at 12 weeks post randomisation. Analyses of primary outcome and safety measures were done in all randomised patients. The trial is registered with ClinicalTrials.gov, number NCT02523131, and is closed to accrual. Findings From May 12, 2016, to Nov 17, 2017, 114 individuals were screened, and 86 eligible patients were randomly assigned to receive hybrid closed-loop therapy (n=46) or sensor-augmented pump therapy (n=40; control group). The proportion of time that glucose concentration was within the target range was significantly higher in the closed-loop group (65%, SD 8) compared with the control group (54%, SD 9; mean difference in change 10·8 percentage points, 95% CI 8·2 to 13·5; p<0·0001). In the closed-loop group, HbA1c was reduced from a screening value of 8·3% (SD 0·6) to 8·0% (SD 0·6) after the 4-week run-in, and to 7·4% (SD 0·6) after the 12-week intervention period. In the control group, the HbA1c values were 8·2% (SD 0·5) at screening, 7·8% (SD 0·6) after run-in, and 7·7% (SD 0·5) after intervention; reductions in HbA1c percentages were significantly greater in the closed-loop group compared with the control group (mean difference in change 0·36%, 95% CI 0·19 to 0·53; p<0·0001). The time spent with glucose concentrations below 3·9 mmol/L (mean difference in change −0·83 percentage points, −1·40 to −0·16; p=0·0013) and above 10·0 mmol/L (mean difference in change −10·3 percentage points, −13·2 to −7·5; p<0·0001) was shorter in the closed-loop group than the control group. The coefficient of variation of sensor-measured glucose was not different between interventions (mean difference in change −0·4%, 95% CI −1·4% to 0·7%; p=0·50). Similarly, total daily insulin dose was not different (mean difference in change 0·031 U/kg per day, 95% CI −0·005 to 0·067; p=0·09) and bodyweight did not differ (mean difference in change 0·68 kg, 95% CI −0·34 to 1·69; p=0·19). No severe hypoglycaemia occurred. One diabetic ketoacidosis occurred in the closed-loop group due to infusion set failure. Two participants in each study group had significant hyperglycaemia, and there were 13 other adverse events in the closed-loop group and three in the control group. Interpretation Hybrid closed-loop insulin delivery improves glucose control while reducing the risk of hypoglycaemia across a wide age range in patients with suboptimally controlled type 1 diabetes. Funding JDRF, NIHR, and Wellcome Trust.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Closing the loop overnight at home setting: psychosocial impact for adolescents with type 1 diabetes and their parents

            Objective To explore the experiences of adolescents with type 1 diabetes mellitus (T1DM) and their parents taking part in an overnight closed loop study at home, using qualitative and quantitative research methods. Research design and methods Adolescents aged 12–18 years on insulin pump therapy were recruited to a pilot closed loop study in the home setting. Following training on the use of a study insulin pump and continuous glucose monitoring (CGM), participants were randomized to receive either real-time CGM combined with overnight closed loop or real-time CGM alone followed by the alternative treatment for an additional 21 days with a 2–3-week washout period in between study arms. Semistructured interviews were performed to explore participants’ perceptions of the impact of the closed loop technology. At study entry and again at the end of each 21-day crossover arm of the trial, participants completed the Diabetes Technology Questionnaire (DTQ) and Hypoglycemia Fear Survey (HFS; also completed by parents). Results 15 adolescents and 13 parents were interviewed. Key positive themes included reassurance/peace of mind, confidence, ‘time off’ from diabetes demands, safety, and improved diabetes control. Key negative themes included difficulties with calibration, alarms, and size of the devices. DTQ results reflected these findings. HFS scores were mixed. Conclusions Closed loop insulin delivery represents cutting-edge technology in the treatment of T1DM. Results indicate that the psychological and physical benefits of the closed loop system outweighed the practical challenges reported. Further research from longitudinal studies is required to determine the long-term psychosocial benefit of the closed loop technology.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial

              The artificial pancreas is an emerging technology for the treatment of type 1 diabetes and two configurations have been proposed: single-hormone (insulin alone) and dual-hormone (insulin and glucagon). We aimed to delineate the usefulness of glucagon in the artificial pancreas system.
                Bookmark

                Author and article information

                Journal
                Diabetes Technol Ther
                Diabetes Technol. Ther
                dia
                Diabetes Technology & Therapeutics
                Mary Ann Liebert, Inc., publishers (140 Huguenot Street, 3rd FloorNew Rochelle, NY 10801USA )
                1520-9156
                1557-8593
                01 March 2019
                01 March 2019
                01 March 2019
                : 21
                : 3
                : 119-127
                Affiliations
                [ 1 ]Usher Institute of Population Health Sciences and Informatics, University of Edinburgh, Edinburgh, United Kingdom.
                [ 2 ]Wellcome Trust-MRC Institute of Metabolic Science, University of Cambridge, Cambridge, United Kingdom.
                [ 3 ]Department of Pediatrics, University of Cambridge, Cambridge, United Kingdom.
                [ 4 ]Leeds Children's Hospital, Leeds, United Kingdom.
                [ 5 ]Manchester Diabetes Center, Manchester Academic Health Science Center, Manchester University NHS Foundation Trust, University of Manchester, Manchester, United Kingdom.
                [ 6 ]Royal Hospital for Sick Children, Edinburgh, United Kingdom.
                Author notes
                [*]Address correspondence to: Julia Lawton, PhD, Usher Institute of Population Health Sciences and Informatics, Medical School, University of Edinburgh, Edinburgh EH8 9AG, United Kingdom j.lawton@ 123456ed.ac.uk
                Article
                10.1089/dia.2018.0306
                10.1089/dia.2018.0306
                6434584
                30720338
                930ea905-f758-4fa6-9141-d0bf1888c976
                © Julia Lawton, et al., 2019; Published by Mary Ann Liebert, Inc.

                This Open Access article is distributed under the terms of the Creative Commons License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.

                History
                Page count
                Tables: 4, References: 32, Pages: 9
                Categories
                Original Articles

                type 1 diabetes,closed-loop system,artificial pancreas,medical device,user experience,qualitative research

                Comments

                Comment on this article