7
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found

      Change in Left Ventricular Diastolic Filling Patterns in Patients with Supraventricular Tachycardia Treated by Radiofrequency Ablation: A Doppler Echocardiographic Study

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To evaluate changes in left ventricular diastolic filling patterns resulting from radiofrequency ablation for supraventricular tachycardia (SVT), 44 patients with SVT undergoing radiofrequency ablation (study group), and 16 patients with SVT undergoing electrophysiologic study without ablation (control group) were studied by pulsed Doppler echocardiography. Peak early diastolic filling velocity (E), peak atrial filling velocity (A), and an E/A ratio were obtained from the transmitral flow velocity pattern before and 24-48 h after ablation or electrophysiologic study. In the study group, E and E/A ratio decreased from 67 ± 16 and 1.26 ± 0.42 to 61 ± 16 cm/sand 1.09 ± 0.39 (p < 0.001), respectively. In the control group, only E/A ratio decreased from 1.40 ± 0.47 to 1.26 ± 0.44 (p < 0.001). Heart rate increased from 71 ± 10 to 80 ± 10 beats/ min (p < 0.001) in the study group and from 67 ± 8 to 72 ± 10 beats/min (p < 0.05) in the control group. E and E/A ratio decreased significantly from 73 ± 17 and 1.35 ± 0.49 to 60 ± 18 cm/s and 0.96 ± 0.40 (p < 0.001) in patients with heart rate change of > 20% after ablation. E, A, and E/A ratio did not change significantly in patients with heart rate change of < 10% and of between 10 and 20% after ablation. Blood pressure and left ventricular ejection fraction did not change in either the study or control groups. It was concluded that left ventricular ejection fraction and Doppler diastolic filling patterns are unaffected by radiofrequency ablation. The decrease in E and E/A ratio in patients with SVT resulted from the more than 20% change in heart rate after radiofrequency ablation.

          Related collections

          Author and article information

          Journal
          CRD
          Cardiology
          10.1159/issn.0008-6312
          Cardiology
          S. Karger AG
          0008-6312
          1421-9751
          1994
          1994
          18 November 2008
          : 85
          : 3-4
          : 193-200
          Affiliations
          aDepartment of Emergency Medicine, Shin-Kong Memorial Hospital, Taipei, and bDivision of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan, ROC
          Article
          176675 Cardiology 1994;85:193–200
          10.1159/000176675
          7987875
          93bf0ad7-61ba-4f2a-b23c-504c10ec91e6
          © 1994 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          : 03 January 1994
          : 23 March 1994
          Page count
          Pages: 8
          Categories
          Arrhythmias, Electrophysiology and Electrocardiography

          General medicine,Neurology,Cardiovascular Medicine,Internal medicine,Nephrology
          Radiofrequency catheterablation,Doppler echocardiography,Left ventricular diastolic filling pattern,Supraventricular tachycardia

          Comments

          Comment on this article