3
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      A better dissolution method for ranitidine tablets USP.

      1
      Pharmaceutical development and technology
      Informa UK Limited

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Ranitidine tablets USP showed variable intra- and inter-lab dissolution results. In order to ascertain the reason for this behavior, ranitidine tablets USP produced by (BIPI) Boehringer Ingelheim Pharmaceuticals Inc., Ridgefield, CT, and Zantac Tablets (brand of ranitidine USP), Glaxo Inc., Research Triangle, NC, were subjected to the compendia (USP) dissolution testing using paddle and basket apparatus. Two potencies of tablets 150 mg and 300 mg were tested. Comparison of BIPI tablets and matching Zantac tablets indicated that both brands of ranitidine tablets USP had similar dissolution behavior. When the basket apparatus was substituted for the paddle apparatus the overall rate and extent of tablet dissolution increased, while the individual tablet variability decreased. BIPI 150 mg tablets using the basket apparatus, but at reduced rotational speed of 30 rpm, showed increase in rate and extent of drug dissolved, with less individual tablet variability compared to the paddle apparatus at 50 rpm. The 300 mg tablet (30 rpm/basket apparatus) had an initial slower rate, but then rapidly equaled the paddle apparatus dissolution results, and had less individual tablet variability. Paddle apparatus tablet sinkers were used to prevent tablets from sticking to the bottom of the dissolution vessel. Overall dissolution for all tablets with sinkers showed a trend which was more rapid and complete than tablets without sinkers. Results showed that dissolution artifacts for ranitidine tablets could be reduced by the use of baskets or tablet sinkers.

          Related collections

          Author and article information

          Journal
          Pharm Dev Technol
          Pharmaceutical development and technology
          Informa UK Limited
          1083-7450
          1083-7450
          2001
          : 6
          : 1
          Affiliations
          [1 ] Pharmaceutics Department, Boehringer Ingelheim Pharmaceuticals Inc., 900 Ridgebury Road, Ridgefield, CT 06877, USA. mcappola@rdg.boehringer-ingelheim.com
          Article
          10.1081/pdt-100000008
          11247270
          94cbec3a-f6e5-4004-aeb3-7fd0d5b79510
          History

          Comments

          Comment on this article