      A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations.

      1 , ,
      Physics in medicine and biology
      IOP Publishing

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A pencil beam algorithm as a component of an optimization algorithm for intensity modulated proton therapy (IMPT) is presented. The pencil beam algorithm is tuned to the special accuracy requirements of IMPT, where in heterogeneous geometries both the position and distortion of the Bragg peak and the lateral scatter pose problems which are amplified by the spot weight optimization. Heterogeneity corrections are implemented by a multiple raytracing approach using fluence-weighted sub-spots. In order to derive nuclear interaction corrections, Monte Carlo simulations were performed. The contribution of long ranged products of nuclear interactions is taken into account by a fit to the Monte Carlo results. Energy-dependent stopping power ratios are also implemented. Scatter in optional beam line accessories such as range shifters or ripple filters is taken into account. The collimator can also be included, but without additional scattering. Finally, dose distributions are benchmarked against Monte Carlo simulations, showing 3%/1 mm agreement for simple heterogeneous phantoms. In the case of more complicated phantoms, principal shortcomings of pencil beam algorithms are evident. The influence of these effects on IMPT dose distributions is shown in clinical examples.

          Related collections

          Author and article information

          Journal
          Phys Med Biol
          Physics in medicine and biology
          IOP Publishing
          0031-9155
          0031-9155
          Nov 07 2005
          : 50
          : 21
          Affiliations
          [1 ] Section for Biomedical Physics, Universitätsklinik für Radioonkologie, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany. Martin.Soukup@med.uni-tuebingen.de
          Article
          S0031-9155(05)00435-5
          10.1088/0031-9155/50/21/010
          16237243
          966f964a-4b31-44a0-bb78-7cff7f123ead
          History

          Comments

          Comment on this article