6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Stenting of the right ventricular outflow tract in the high-risk infant with cyanotic teratology of Fallot.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Neonatal tetralogy of Fallot (TOF) repair carries an increased risk of low birthweight or premature infants. Studies are investigating stents in the right ventricular outflow tract (RVOT) as an alternative to aortopulmonary shunts. The authors review their institutional experience with RVOT stenting in the high-risk infant with TOF. Data on sequential patients who received RVOT stents were reviewed, with collection of their surgical, echocardiographic, and catheterization data. Size-matched control subjects were identified and outcomes compared. Six infants went to the catheterization lab for RVOT stenting from 2008 to 2010. Five of these patients had placement of an RVOT stent after balloon dilation. The median saturations were 71% on 48% fraction of inspired oxygen (FiO2), with improvement to 94% (p < 0.001) on 39% FiO2 24 h after stent placement. As shown by echocardiography, the diameter of the median right pulmonary artery (RPA) was 2.6 mm (z-score, -3.3), and the diameter of the left pulmonary artery (LPA) was 2.0 mm (z-score, -4.5). Repeat echocardiography before surgery showed a statistically significant increase in RPA and LPA size as well as a modified McGoon ratio (p < 0.05). Four of the five patients subsequently underwent TOF repair. No stent fractures occurred. One patient had repair 10 days after stent placement secondary to stent malposition and tricuspid valve injury. The authors' experience with stents in the RVOT of TOF patients has yielded good results, with significant improvement in oxygen saturations. Patients had successful elective surgical repair and stent removal without longer cardiopulmonary bypass times or recognizable complications compared with shunted patients.

          Related collections

          Author and article information

          Journal
          Pediatr Cardiol
          Pediatric cardiology
          Springer Nature America, Inc
          1432-1971
          0172-0643
          Mar 2014
          : 35
          : 3
          Affiliations
          [1 ] Cincinnati Children's Hospital and Medical Center, 3333 Burnet Avenue, MLC 2003, Cincinnati, OH, 45229-3026, USA, chesney.castleberry@cchmc.org.
          Article
          10.1007/s00246-013-0796-z
          24096718
          96c525bb-57e8-4eb8-b752-f00742d72dfe
          History

          Comments

          Comment on this article