      Establishment of an open database of realistic simulated data for evaluation of partial volume correction techniques in brain PET/MR

      abstract

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The Partial Volume (PV) effect in Positron Emission Tomography (PET) imaging leads to loss in quantification accuracy, which manifests in PV effects (small objects occupy partially the sensitive volume of the imaging instrument, resulting in blurred images). Simultaneous acquisition of PET and Magnetic Resonance Imaging (MRI) produces concurrent metabolic and anatomical information. The latter has proved to be very helpful for the correction of PV effects. Currently, there are several techniques used for PV correction. They can be applied directly during the reconstruction process or as a post-processing step after image reconstruction. In order to evaluate the efficacy of the different PV correction techniques in brain- PET, we are constructing a database of simulated data. Here we present the framework and steps involved in constructing this database. Static 18F-FDG epilepsy and 18F-Florbetapir amyloid dementia PET/MR were selected because of their very different characteristics. The methodology followed was based on four main steps: Image pre-processing, Ground Truth (GT) generation, MRI and PET data simulation and reconstruction. All steps used Open Source software and can therefore be repeated at any centre. The framework as well as the database will be freely accessible. Tools used included GIF, FSL, POSSUM, GATE and STIR. The final data obtained after simulation, involving raw or reconstructed PET data together with corresponding MRI datasets, were close to the original patient data. Besides, there is the advantage that data can be compared with the GT. We indicate several parameters that can be improved and optimized.

          Related collections

          Author and article information

          Conference
          EJNMMI Phys
          EJNMMI Phys
          EJNMMI Physics
          Springer International Publishing (Cham )
          2197-7364
          18 May 2015
          18 May 2015
          December 2015
          : 2
          Issue : Suppl 1 Issue sponsor : Publication of this supplement was funded by COST (European Cooperation in Science and Technology).
          : A44
          Affiliations
          [1 ]Instituto de Biofísica e Engenharia Biomédica, FC-UL, Lisboa, Portugal
          [2 ]Institute of Nuclear Medicine, UCL, London, UK
          [3 ]Centre of Medical Image Computing, UCL, London, UK
          [4 ]INSERM UMR1101, LaTIM, CHRU de Brest, Brest, France
          Article
          154
          10.1186/2197-7364-2-S1-A44
          4798662
          26956302
          9759c237-5cff-4d46-b5eb-eef2bc8241d8
          © Mota et al; licensee Springer. 2015

          This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

          PSMR 2015: 4th Conference on PET/MR and SPECT/MR
          La Biodola, Isola d'Elba, Italy
          17-21 May 2015
          History
          Categories
          Meeting Abstract
          Custom metadata
          © The Author(s) 2015

          Comments

          Comment on this article