      Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ) parameters, including carbon monoxide (CO), nitrogen dioxide (NO2 ), formaldehyde (CH2 O), selected volatile organic compounds (benzene, toluene, ethylbenzene, and xylenes (BTEX), radon, and microbial content in settled dust were measured before and after the retrofits. After the retrofits, heating energy consumption decreased by an average of 24% and 49% in Finnish and Lithuanian buildings, respectively. After the retrofits of Finnish buildings, there was a significant increase in BTEX concentrations (estimated mean increase of 2.5 µg/m3 ), whereas significant reductions were seen in fungal (0.6-log reduction in cells/m2 /d) and bacterial (0.6-log reduction in gram-positive and 0.9-log reduction in gram-negative bacterial cells/m2 /d) concentrations. In Lithuanian buildings, radon concentrations were significantly increased (estimated mean increase of 13.8 Bq/m3 ) after the retrofits. Mechanical ventilation was associated with significantly lower CH2 O concentrations in Finnish buildings. The results and recommendations presented in this paper can inform building retrofit studies and other programs and policies aimed to improve indoor environment and health.

          Related collections

          Author and article information

          Journal
          Indoor Air
          Indoor air
          Wiley
          1600-0668
          0905-6947
          July 2019
          : 29
          : 4
          Affiliations
          [1 ] Department of Health Security, National Institute for Health and Welfare, Kuopio, Finland.
          [2 ] Department of Civil Engineering, Tampere University, Tampere, Finland.
          [3 ] Department of Environmental Technology, Kaunas University of Technology, Kaunas, Lithuania.
          Article
          10.1111/ina.12555
          30921480
          97d42483-ebee-471e-8d96-d894b2efd86d
          History

          radon,residential building,fungi,chemical exposure,microbial exposure,bacteria

          Comments

          Comment on this article