          The characteristics of a waveguide-coupled bimetallic surface plasmon resonance (WcBiM SPR) sensor using (3-dimethylaminopropyl)-3-ethylcarbodiimide(EDC)-N-hydroxysuccinimide(NHS)-activated protein A was investigated, and the detection of IgG using the EDC-NHS-activated protein A was studied in comparison with protein A and a self-assembled monolayer (SAM). The WcBiM sensor, which has a narrower full width at half maximum (FWHM) and a steeper slope, was selected since it leads to a larger change in the reflectance in the intensity detection mode. A preparation of the EDC-NHS-activated protein A for site-directed immobilization of antibodies was relative easily compared to the engineered protein G and A. In antigen-antibody interactions, the response to IgG at the concentrations of 50, 100, and 150 ng/ml was investigated. The results showed that the sensitivity of the WcBiM sensor using the EDC-NHS-activated protein A, protein A, and SAM was 0.0185 [%/(ng/ml)], 0.0065 [%/(ng/ml)], and 0.0101 [%/(ng/ml)], respectively. The lowest detectable concentrations of IgG with the EDC-NHS-activated protein A, protein A, and SAM were 4.27, 12.83, and 8.24 ng/ml, respectively. Therefore, the increased sensitivity and lower detection capability of the WcBiM SPR chip with the EDC-NHS-activated protein A suggests that it could be used in early diagnosis where the trace level concentrations of biomolecules should be detected.

          Related collections

          Author and article information

          Journal
          J Biomed Opt
          Journal of biomedical optics
          SPIE-Intl Soc Optical Eng
          1560-2281
          1083-3668
          May 2014
          : 19
          : 5
          Article
          1813948
          10.1117/1.JBO.19.5.051209
          24418847
          9929773d-6277-4652-87e3-212f9122acc9
          History

          Comments

          Comment on this article