      PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study

      research-article
      * , , ,
      Wear
      Elsevier
      PEEK, CFR-PEEK, Knee replacement, Wear

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          New bearing materials for total joint replacement have been explored as the need to improve longevity and enhance performance is driven by the changing demands of the patient demographic. Carbon-reinforced PEEK has demonstrated good wear characteristics in experimental wear simulation in both simple geometry pin-on-plate studies and in total hip joint replacement. Carbon reinforced PEEK CFR-PEEK has the potential to reduce tibial insert thickness and preserve bone in the knee.

          This study investigated the wear performance of PEEK and CFR-PEEK in a low conformity total knee replacement configuration. Custom-made flat inserts were tested against cobalt-chromium femoral bearings in a knee wear simulation for a period of three million cycles. Wear was assessed gravimetrically at intervals throughout the study.

          The wear rates of both PEEK and CFR-PEEK were very high and almost two orders of magnitude higher than the wear rate of UHMWPE under comparable conditions. Evidence of mechanical failure of the materials, including surface cracking and delamination was observed in both materials.

          This study highlights that these materials may not be suitable alternatives for UHMWPE in low-conformity designs.

          Highlights

          • Study investigated wear of PEEK and CFR-PEEK as alternative to PE in TKR.

          • Very high wear rates observed for both PEEK and CFR-PEEK.

          • Wear rates two orders of magnitude higher than UHWMPE under same conditions.

          • Evidence of mechanical failure of PEEK and CFR-PEEK materials.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: not found

          Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty.

          S. Kurtz (1999)
          Despite the recognized success and worldwide acceptance of total joint arthroplasty, wear is a major obstacle limiting the longevity of implanted UHMWPE components. Efforts to solve the wear problem in UHMWPE have spurred numerous detailed studies into the structure, morphology, and mechanical properties of the polymer at every stage of its production from original resin into stock material and final fabricated form. Scientific developments in this field are occurring at an accelerating rate, and periodic review of UHMWPE technology is therefore increasingly necessary. The present article provides a four-part comprehensive review of technological advancements in the processing, manufacture, sterilization, and crosslinking of UHMWPE for total joint replacements. The first part of this article describes the recently updated nomenclature of UHMWPE, including the process of resin production and conversion to stock material. The second part outlines the methods of manufacturing UHMWPE into joint replacement components and provides overviews of alternate forms of UHMWPE, namely carbon-fiber reinforced UHMWPE (Poly II) and UHMWPE recrystallized under high temperature and pressure (Hylamer). The third part summarizes the sterilization and degradation of UHMWPE. Newly developed methods for accelerating the oxidation of UHMWPE after sterilization (for preconditioning of test specimens), as well as methods for quantifying the oxidation of UHMWPE, are also discussed. Finally, the fourth part reviews the development and properties of crosslinked UHMWPE, a promising alternate biomaterial for total joint replacements.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The influence of design, materials and kinematics on the in vitro wear of total knee replacements.

            Debris-induced osteolysis due to surface wear of ultra high molecular weight polyethylene (UHMWPE) bearings is a potential long-term failure mechanism of total knee replacements (TKR). This study investigated the effect of prosthesis design, kinematics and bearing material on the wear of UHMWPE bearings using a physiological knee simulator. The use of a curved fixed bearing design with stabilised polyethylene bearings reduced wear in comparison to more flat-on-flat components which were sterilised by gamma irradiation in air. Medium levels of crosslinking further improved the wear resistance of fixed bearing TKR due to resistance to strain softening when subjected to multidirectional motion at the femoral-insert articulating interface. Backside motion was shown to be a contributing factor to the overall rate of UHMWPE wear in fixed bearing components. Wear of fixed bearing prostheses was reduced significantly when anterior-posterior displacement and internal-external rotation kinematics were reduced due to decreased cross shear on the articulating surface and a reduction in AP displacement. Rotating platform mobile bearing prostheses exhibited reduced wear rates in comparison to fixed bearing components in these simulator studies due to redistribution of knee motion to two articulating interfaces with more linear motions at each interface. This was observed in two rotating platform designs with different UHMWPE bearing materials. In knee simulator studies, wear of TKR bearings was dependent on kinematics at the articulating surfaces and the prosthesis design, as well as the type of material.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Survival analysis of total knee arthroplasty at a minimum 10 years' follow-up: a multicenter French nationwide study including 846 cases.

              Survivorship for modern total knee arthroplasties (TKA) is not precisely known from large series, other than registries. The present retrospective study therefore analyzed 846 TKAs at a minimum 10 years' follow-up.
                Bookmark

                Author and article information

                Contributors
                Journal
                Wear
                Wear
                Wear
                Elsevier
                0043-1648
                1873-2577
                15 March 2017
                15 March 2017
                : 374-375
                : 86-91
                Affiliations
                [0005]Institute of Medical and Biological Engineering, University of Leeds, UK
                Author notes
                [* ]Corresponding author. C.L.Brockett@ 123456leeds.ac.uk
                Article
                S0043-1648(16)30749-9
                10.1016/j.wear.2016.12.010
                5328191
                9a8cf6a5-389e-4c87-9993-f5c0d8068364
                © 2017 The Authors

                This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

                History
                : 16 August 2016
                : 3 December 2016
                : 6 December 2016
                Categories
                Article

                peek,cfr-peek,knee replacement,wear
                peek, cfr-peek, knee replacement, wear

                Comments

                Comment on this article