          Abstract

          Background

          Aortic elastic properties are determinants of left ventricular function by means of ventriculo-arterial coupling and indicators of cardiovascular risk. Aortic valve stenosis surgical replacement temporary reduces aortic function damaging vasa vasorum, while transcatheter aortic valve implantation (TAVI) does not influence it in the short term. We studied aortic distensibility, stiffness, M-mode strain and tissue strain after 6 and 12 months from TAVI.

          Methods

          We enrolled 15 patients with symptomatic severe aortic stenosis who underwent CoreValve prosthesis (Medtronic, Minneapolis, MN) implantation. Everyone had blood pressure measurement and echocardiography registration before TAVI and after 6 and 12 months.

          Results

          After TAVI NYHA class (p = 0.016), peak and mean aortic valve gradients (p < 0.001 for both) improved. Aortic distensibility increased (p = 0.032 in the first 6 months, p = 0.005 in the second 6 months, and p = 0.003 from baseline to 12 months), as well as stiffness decreased (p = 0.034; 0.090; 0.001), M-mode strain and tissue strain ameliorated (p = 0.041; 0.004; 0.004; and p = 0.013; 0.002; 0.001, respectively), tissue Doppler imaging improved (S′ wave: p = 0.289; 0.347; 0.018. E′ wave: p = 0.018; 0.113; 0.007. A′ wave: p = 0.002; 0.532; 0.001). Moreover, some left ventricular parameters improved at 6 months, such as ejection fraction (from 49 ± 16 to 57 ± 11%; p = 0.044) and diastolic interventricular septum thickness (from 14 ± 2 to 12 ± 2 mm; p = 0.010). Even systolic pulmonary artery pressure (p = 0.019) and left diastolic dysfunction grade ameliorated (p = 0.042).

          Conclusions

          For the first time we demonstrated that aortic elastic properties improve at 6 and 12 months after TAVI, thus influencing ventriculo-arterial coupling and ameliorating left ventricular function.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease.

          To identify the characteristics, treatment, and outcomes of contemporary patients with valvular heart disease (VHD) in Europe, and to examine adherence to guidelines. The Euro Heart Survey on VHD was conducted from April to July 2001 in 92 centres from 25 countries; it included prospectively 5001 adults with moderate to severe native VHD, infective endocarditis, or previous valve intervention. VHD was native in 71.9% of patients and 28.1% had had a previous intervention. Mean age was 64+/-14 years. Degenerative aetiologies were the most frequent in aortic VHD and mitral regurgitation while most cases of mitral stenosis were of rheumatic origin. Coronary angiography was used in 85.2% of patients before intervention. Of the 1269 patients who underwent intervention, prosthetic replacement was performed in 99.0% of aortic VHD, percutaneous dilatation in 33.9% of mitral stenosis, and valve repair in 46.5% of mitral regurgitation; 31.7% of patients had > or =1 associated procedure. Of patients with severe, symptomatic, single VHD, 31.8% did not undergo intervention, most frequently because of comorbidities. In asymptomatic patients, accordance with guidelines ranged between 66.0 and 78.5%. Operative mortality was <5% for single VHD. This survey provides unique contemporary data on characteristics and management of patients with VHD. Adherence to guidelines is globally satisfying as regards investigations and interventions.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            European system for cardiac operative risk evaluation (EuroSCORE).

            To construct a scoring system for the prediction of early mortality in cardiac surgical patients in Europe on the basis of objective risk factors. The EuroSCORE database was divided into developmental and validation subsets. In the former, risk factors deemed to be objective, credible, obtainable and difficult to falsify were weighted on the basis of regression analysis. An additive score of predicted mortality was constructed. Its calibration and discrimination characteristics were assessed in the validation dataset. Thresholds were defined to distinguish low, moderate and high risk groups. The developmental dataset had 13,302 patients, calibration by Hosmer Lemeshow Chi square was (8) = 8.26 (P 200 micromol/l (2), active endocarditis (3) and critical preoperative state (3). Cardiac factors were unstable angina on intravenous nitrates (2), reduced left ventricular ejection fraction (30-50%: 1, 60 mmHg (2). Operation-related factors were emergency (2), other than isolated coronary surgery (2), thoracic aorta surgery (3) and surgery for postinfarct septal rupture (4). The scoring system was then applied to three risk groups. The low risk group (EuroSCORE 1-2) had 4529 patients with 36 deaths (0.8%), 95% confidence limits for observed mortality (0.56-1.10) and for expected mortality (1.27-1.29). The medium risk group (EuroSCORE 3-5) had 5977 patients with 182 deaths (3%), observed mortality (2.62-3.51), predicted (2.90-2.94). The high risk group (EuroSCORE 6 plus) had 4293 patients with 480 deaths (11.2%) observed mortality (10.25-12.16), predicted (10.93-11.54). Overall, there were 698 deaths in 14,799 patients (4.7%), observed mortality (4.37-5.06), predicted (4.72-4.95). EuroSCORE is a simple, objective and up-to-date system for assessing heart surgery, soundly based on one of the largest, most complete and accurate databases in European cardiac surgical history. We recommend its widespread use.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Arterial stiffness: a new cardiovascular risk factor?

                Bookmark

                Author and article information

                Contributors
                Journal
                Int J Cardiol Heart Vessel
                Int J Cardiol Heart Vessel
                International Journal of Cardiology. Heart & Vessels
                Elsevier
                2214-7632
                26 April 2014
                September 2014
                26 April 2014
                : 4
                : 198-202
                Affiliations
                [a ]Section of Cardiovascular Diseases, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Italy
                [b ]Cardiovascular Research Institute Maastricht — CARIM, Maastricht University Medical Centre, The Netherlands
                [c ]Cardiac Surgery Unit, Spedali Civili of Brescia, Italy
                Author notes
                [* ]Corresponding author at: Piazzale Spedali Civili 1, 25123 Brescia, Italy. Tel.: + 39 0303995679; fax: + 39 0303996801Corresponding author at: Piazzale Spedali Civili 1Tel.: + 39 0303995679; fax: + 39 0303996801Brescia25123Italy enrico.vizzardi@ 123456tin.it
                Article
                S2214-7632(14)00022-4
                10.1016/j.ijchv.2014.04.003
                5801439
                9b40710c-adf3-43bb-9856-c2436e75ef03
                © 2014 The Authors

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).

                History
                : 10 March 2014
                : 13 April 2014
                Categories
                Article

                tavi,strain,doppler echocardiography,aorta,distensibility,stiffness

                Comments

                Comment on this article