      Regression patterns of choroidal melanoma: After palladium-103 ( 103Pd) plaque brachytherapy

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose:

          To describe the patterns of regression of choroidal melanoma after treatment with plaque brachytherapy.

          Methods:

          Retrospective interventional case series including 170 consecutive patients treated with 103Pd eye plaque radiation for choroidal melanoma. Outcome measures were changes in tumor thickness, surface characteristics, tumor vascularity, ultrasonography, fluorescein angiography, optical coherence tomography, and histopathology.

          Results:

          The mean initial tumor thickness was 3.9 mm (median 2.8 mm; range 2–11.3 mm) that decreased to 1.7 mm (median 1.2 mm; range 0–7.1 mm) after plaque brachytherapy. On imaging, tumors were pigmented in 51% ( n = 86/170), amelanotic in 10% ( n = 17/170), and variably pigmented in 39% ( n = 67/170). Tumor pigmentation increased in 64% ( n = 106/166), decreased in 18% ( n = 30/166), and was unchanged in 18% ( n = 30/166). Of the 120 that demonstrated intrinsic vascularity, 10% ( n = 12/120) had decreased tumor-related vascularity and 90% ( n = 108/120) showed complete resolution. Subretinal fluid was present in 34% ( n = 58/170) of eyes at presentation. Of them, 15% (9; n = 9/58) had persistent SRF at last follow-up. On ultrasound imaging, 88% ( n = 149/170) tumors presented with low to moderate internal reflectivity of which 61% ( n = 91/149) showed increased reflectivity on regression. We noted a crescendo–decrescendo fluctuation in the presence of orange pigment lipofuscin along with complete resolution of drusenoid retinal pigment epithelial detachments. In the entire series of 170 patients, there was 0.5% (1) failure of local control, 2% (4) secondary enucleations, and 6% (10) patients developing metastasis.

          Conclusion:

          Findings related to choroidal melanoma regression after 103Pd plaque brachytherapy included decreased intrinsic tumor vascularity, decreased tumor-related subretinal fluid, increased pigmentation, specific changes in orange pigment lipofuscin and resolution of drusenoid retinal pigment epithelial detachments, as well as decreased tumor thickness with an increase in internal reflectivity on ultrasound.

          Related collections

          Most cited references47

          • Record: found
          • Abstract: found
          • Article: not found

          The American Brachytherapy Society consensus guidelines for plaque brachytherapy of uveal melanoma and retinoblastoma.

          (2014)
          To present the American Brachytherapy Society (ABS) guidelines for plaque brachytherapy of choroidal melanoma and retinoblastoma.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            International Validation of the American Joint Committee on Cancer's 7th Edition Classification of Uveal Melanoma.

            (2015)
            Although an accurate uveal melanoma staging system is needed to improve research and patient care, the evaluation of eye cancer staging systems requires international multicenter data sharing to acquire a statistically significant analysis.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Dosimetry of (125)I and (103)Pd COMS eye plaques for intraocular tumors: report of Task Group 129 by the AAPM and ABS.

              Dosimetry of eye plaques for ocular tumors presents unique challenges in brachytherapy. The challenges in accurate dosimetry are in part related to the steep dose gradient in the tumor and critical structures that are within millimeters of radioactive sources. In most clinical applications, calculations of dose distributions around eye plaques assume a homogenous water medium and full scatter conditions. Recent Monte Carlo (MC)-based eye-plaque dosimetry simulations have demonstrated that the perturbation effects of heterogeneous materials in eye plaques, including the gold-alloy backing and Silastic insert, can be calculated with reasonable accuracy. Even additional levels of complexity introduced through the use of gold foil "seed-guides" and custom-designed plaques can be calculated accurately using modern MC techniques. Simulations accounting for the aforementioned complexities indicate dose discrepancies exceeding a factor of ten to selected critical structures compared to conventional dose calculations. Task Group 129 was formed to review the literature; re-examine the current dosimetry calculation formalism; and make recommendations for eye-plaque dosimetry, including evaluation of brachytherapy source dosimetry parameters and heterogeneity correction factors. A literature review identified modern assessments of dose calculations for Collaborative Ocular Melanoma Study (COMS) design plaques, including MC analyses and an intercomparison of treatment planning systems (TPS) detailing differences between homogeneous and heterogeneous plaque calculations using the American Association of Physicists in Medicine (AAPM) TG-43U1 brachytherapy dosimetry formalism and MC techniques. This review identified that a commonly used prescription dose of 85 Gy at 5 mm depth in homogeneous medium delivers about 75 Gy and 69 Gy at the same 5 mm depth for specific (125)I and (103)Pd sources, respectively, when accounting for COMS plaque heterogeneities. Thus, the adoption of heterogeneous dose calculation methods in clinical practice would result in dose differences >10% and warrant a careful evaluation of the corresponding changes in prescription doses. Doses to normal ocular structures vary with choice of radionuclide, plaque location, and prescription depth, such that further dosimetric evaluations of the adoption of MC-based dosimetry methods are needed. The AAPM and American Brachytherapy Society (ABS) recommend that clinical medical physicists should make concurrent estimates of heterogeneity-corrected delivered dose using the information in this report's tables to prepare for brachytherapy TPS that can account for material heterogeneities and for a transition to heterogeneity-corrected prescriptive goals. It is recommended that brachytherapy TPS vendors include material heterogeneity corrections in their systems and take steps to integrate planned plaque localization and image guidance. In the interim, before the availability of commercial MC-based brachytherapy TPS, it is recommended that clinical medical physicists use the line-source approximation in homogeneous water medium and the 2D AAPM TG-43U1 dosimetry formalism and brachytherapy source dosimetry parameter datasets for treatment planning calculations. Furthermore, this report includes quality management program recommendations for eye-plaque brachytherapy.
                Bookmark

                Author and article information

                Journal
                Eur J Ophthalmol
                Eur J Ophthalmol
                EJO
                spejo
                European Journal of Ophthalmology
                SAGE Publications (Sage UK: London, England )
                1120-6721
                1724-6016
                22 May 2018
                November 2018
                : 28
                : 6
                : 722-730
                Affiliations
                [1-1120672118776146]The New York Eye Cancer Center, New York, NY, USA
                Author notes
                [*]Paul T Finger, The New York Eye Cancer Center, 115 East 61st Street—Suite 5B, New York, NY 10065, USA. Email: pfinger@ 123456eyecancer.com
                Article
                10.1177_1120672118776146
                10.1177/1120672118776146
                6210576
                29788760
                9c2fb0ca-715b-4709-91af-3cd4d9dae06c
                © The Author(s) 2018

                This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License ( http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages ( https://us.sagepub.com/en-us/nam/open-access-at-sage).

                History
                : 19 December 2017
                : 20 April 2018
                Categories
                Original Research Articles

                choroidal melanoma,regression,pigment,exudative,ultrasound
                choroidal melanoma, regression, pigment, exudative, ultrasound

                Comments

                Comment on this article