19
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Floc characterization and membrane fouling of polyferric-polymer dual/composite coagulants in coagulation/ultrafiltration hybrid process.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Papermaking sludge and spent pickling liquor were recycled to synthesize a macromolecular lignin-acrylamide polymer (LA) and polyferric chloride (PFC), respectively. The dual-coagulant PFC-LA (PFC and LA were dosed orderly), composite coagulant PFCLA (PFC and LA premixed before dosed) and PFC were used in coagulation/ultrafiltration hybrid process in surface water treatment. The objectives of this paper are to comparatively investigate final water quality after coagulation and coagulation/ultrafiltration process and floc properties, including floc size, strength, recoverability and floc structure, with or without LA addition. Additionally, the relationship between membrane fouling and floc characteristics was discussed. The results showed that best final water quality was obtained by PFC-LA, sequentially followed by PFCLA and PFC. Floc size, growth rate, strength and recoverability as well as fractal dimension were also in the order of PFC-LA>PFCLA>PFC. The maximum permeate fluxes before and after backwash operation were obtained by PFC-LA, which gave the largest and most compact flocs. Coagulation suspension after breakage resulted in much more serious membrane fouling for PFC, whereas permeate flux slightly decreased when LA was used in combination with PFC.

          Related collections

          Author and article information

          Journal
          J Colloid Interface Sci
          Journal of colloid and interface science
          1095-7103
          0021-9797
          Dec 15 2013
          : 412
          Affiliations
          [1 ] Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, No. 27 Shanda South Road, Jinan, 250100 Shandong, People's Republic of China.
          Article
          S0021-9797(13)00827-8
          10.1016/j.jcis.2013.09.013
          24144372
          9e048e14-274b-41ca-9632-d0ca8336739b
          Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.
          History

          Floc properties,Membrane fouling,Papermaking sludge,Spent pickling liquor

          Comments