10
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Human Electroretinal Responses to Grating Patterns and Defocus Changes by Global Flash Multifocal Electroretinogram

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The electrical response of the retina was examined as a function of retinal region, using stimuli of various spatial frequencies in the first experiment. In the second experiment, the regional response of the retina to defocus at high and low spatial frequencies was investigated. Twenty three subjects were recruited for global flash multifocal electroretinogram (mfERG) in experiment 1. Black and white gratings (printed on plastic transparent sheets) of four spatial frequencies (SF), 0.24, 1.2, 2.4 and 4.8 cycle per degree were presented in front of the mfERG stimulation. The amplitudes and implicit times of the direct (DC) and induced (IC) components of mfERG responses were pooled into six concentric rings for analysis. There was low amplitude DC at low SF, which increased with increasing SF, and which decreased with increasing eccentricity. The IC was high in amplitude at all SF and reduced in amplitude with increasing eccentricity. Our findings suggested that outer and inner retina had different characteristics in processing spatial details. In experiment 2, Twenty-three young adults were recruited for mfERG measurement. The retinal electrical responses for low (0.24cpd) and high (4.8cpd) SF under fully corrected conditions of short-term negative defocus (-2D) and short term positive defocus (+2D) conditions were measured. There was a sign-dependent response to defocus in the DC response, mainly in peripheral regions. The sign dependent response at low SF was more obvious than that at high SF, and was located more peripherally. The IC response showed no clear trends for either defocus condition. The human retina seems to have a decoding system for optical defocus, which was tuned for low spatial frequency, and was located in the retinal near periphery.

          Related collections

          Most cited references62

          • Record: found
          • Abstract: found
          • Article: not found

          Homeostasis of eye growth and the question of myopia.

          As with other organs, the eye's growth is regulated by homeostatic control mechanisms. Unlike other organs, the eye relies on vision as a principal input to guide growth. In this review, we consider several implications of this visual guidance. First, we compare the regulation of eye growth to that of other organs. Second, we ask how the visual system derives signals that distinguish the blur of an eye too large from one too small. Third, we ask what cascade of chemical signals constitutes this growth control system. Finally, if the match between the length and optics of the eye is under homeostatic control, why do children so commonly develop myopia, and why does the myopia not limit itself? Long-neglected studies may provide an answer to this last question.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Retardation of myopia in Orthokeratology (ROMIO) study: a 2-year randomized clinical trial.

            This single-masked randomized clinical trial aimed to evaluate the effectiveness of orthokeratology (ortho-k) for myopic control. A total of 102 eligible subjects, ranging in age from 6 to 10 years, with myopia between 0.50 and 4.00 diopters (D) and astigmatism not more than 1.25D, were randomly assigned to wear ortho-k lenses or single-vision glasses for a period of 2 years. Axial length was measured by intraocular lens calculation by a masked examiner and was performed at the baseline and every 6 months. This study was registered at ClinicalTrials.gov, number NCT00962208. In all, 78 subjects (37 in ortho-k group and 41 in control group) completed the study. The average axial elongation, at the end of 2 years, were 0.36 ± 0.24 and 0.63 ± 0.26 mm in the ortho-k and control groups, respectively, and were significantly slower in the ortho-k group (P 0.54) but was correlated with the initial age of the subjects (P 1.00D per year) were 65% and 13% in younger (age range: 7-8 years) and older (age range: 9-10 years) children, respectively, in the control group and were 20% and 9%, respectively, in the ortho-k group. Five subjects discontinued ortho-k treatment due to adverse events. On average, subjects wearing ortho-k lenses had a slower increase in axial elongation by 43% compared with that of subjects wearing single-vision glasses. Younger children tended to have faster axial elongation and may benefit from early ortho-k treatment. (ClinicalTrials.gov number, NCT00962208.).
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The contrast sensitivity of retinal ganglion cells of the cat.

              1. Spatial summation within cat retinal receptive fields was studied by recording from optic-tract fibres the responses of ganglion cells to grating patterns whose luminance perpendicular to the bars varied sinusoidally about the mean level. 2. Summation over the receptive fields of some cells (X-cells) was found to be approximately linear, while for other cells (Y-cells) summation was very non-linear. 3. The mean discharge frequency of Y-cells (unlike that of X-cells) was greatly increased when grating patterns drifted across their receptive fields. 4. In twenty-one X-cells the relation between the contrast and spatial frequency of drifting sinusoidal gratings which evoked the same small response was measured. In every case it was found that the reciprocal of this relation, the contrast sensitivity function, could be satisfactorily described by the difference of two Gaussian functions. 5. This finding supports the hypothesis that the sensitivities of the antagonistic centre and surround summating regions of ganglion cell receptive fields fall off as Gaussian functions of the distance from the field centre. 6. The way in which the sensitivity of an X-cell for a contrast-edge pattern varied with the distance of the edge from the receptive field centre was determined and found to be consistent with the cell's measured contrast sensitivity function. 7. Reducing the retinal illumination produced changes in the contrast sensitivity function of an X-cell which suggested that the diameters of the summating regions of the receptive field increased while the surround region became relatively ineffective.
                Bookmark

                Author and article information

                Contributors
                Role: Academic Editor
                Journal
                PLoS One
                PLoS ONE
                plos
                plosone
                PLoS ONE
                Public Library of Science (San Francisco, CA USA )
                1932-6203
                13 April 2015
                2015
                : 10
                : 4
                : e0123480
                Affiliations
                [001]Laboratory of Experimental Optometry (Neuroscience), School of Optometry, Hong Kong Polytechnic University, Hong Kong SAR, China
                University of Florida, UNITED STATES
                Author notes

                Competing Interests: The authors have declared that no competing interests exist.

                Conceived and designed the experiments: MC HC. Performed the experiments: MC. Analyzed the data: MC PC HC. Contributed reagents/materials/analysis tools: AC HC. Wrote the paper: MC HC.

                Article
                PONE-D-14-47363
                10.1371/journal.pone.0123480
                4395308
                25874564
                9f39c7f4-4d6e-4ec8-863d-920ff4212522
                Copyright @ 2015

                This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

                History
                : 29 October 2014
                : 19 February 2015
                Page count
                Figures: 8, Tables: 1, Pages: 21
                Funding
                This study was supported by the General Research Fund (PolyU 5605/13M) from The Research Grants Committee of the Hong Kong SAR and the associated fund (Research Postgraduate) from The Hong Kong Polytechnic University. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
                Categories
                Research Article
                Custom metadata
                All relevant data are within the paper and its Supporting Information files.

                Uncategorized
                Uncategorized

                Comments

                Comment on this article