4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Adding access blood flow surveillance to clinical monitoring reduces thrombosis rates and costs, and improves fistula patency in the short term: a controlled cohort study

      , , , , , , ,
      Nephrology Dialysis Transplantation
      Oxford University Press (OUP)

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: found
          • Article: not found

          Randomized, Controlled Trials, Observational Studies, and the Hierarchy of Research Designs

          New England Journal of Medicine, 342(25), 1887-1892
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Recommended standards for reports dealing with arteriovenous hemodialysis accesses.

            The incidence rate of treated end-stage renal disease in the united states is 180 per million and continues to rise at a rate of 7.8% per year. Arteriovenous hemodialysis access (AV access) creation and maintenance are two of the most difficult issues associated with the management of patients on hemodialysis. The 1-year complication rate of a primary prosthetic AV access for hemodialysis ranges from 33% to 99%. Various investigators report on patency and complications of AV access. However, it is rather difficult to compare outcomes because of the wide variety of access materials, configurations, locations, risk factors, and quality of inflow and outflow vessels. Although there have been reporting standards for dialysis access endovascular interventions and for central venous access placement, standards regarding surgical access placement and its revision are lacking. The "Dialysis Outcome Quality Initiative," published by the National Kidney Foundation, provides recommendations for optimal clinical practices aimed at improving dialysis outcome and patient survival. This reporting standards document is not meant to be a "practice guidelines" or "best practices" document. Rather, the purpose of this document is to provide standardized definitions related to AV access procedures and to recommend reporting standards for patency and complications, to be used by surgeons, nephrologists, and interventional radiologists, that will permit meaningful comparisons among AV access procedures. The terms, definitions, and categories featured in this article have been approved by the Committee on Reporting Standards of the Society for Vascular Surgery and the American Association for Vascular Surgery and should be observed in preparing manuscripts on AV accesses for submission to the Journal Of Vascular Surgery.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Vascular access blood flow monitoring reduces access morbidity and costs.

              Vascular access morbidity results in suboptimal patient outcomes and costs more than $8000 per patient-year at risk, representing approximately 15% of total Medicare expenditures for ESRD patients annually. In recent years, the rate of access thrombosis has improved following the advent of vascular access blood flow monitoring (VABFM) programs to identify and treat stenosis prior to thrombosis. To define further both the clinical and financial impact of such programs, we used the ultrasound dilution method to study the effects of VABFM on thrombosis-related morbid events and associated costs, compared with both dynamic venous pressure monitoring (DVPM) and no monitoring (NM) in arteriovenous fistulas (AVF) and grafts. A total of 132 chronic hemodialysis patients were followed prospectively for three consecutive study phases (I, 11 months of NM; II, 12 months of DVPM; III, 10 months of VABFM). All vascular access-related information (thrombosis rate, hospitalization, angiogram, angioplasty, access surgery, thrombectomy, catheter placement, missed treatments) was collected during the three study periods. During the three study phases, graft thrombosis rate was reduced from 0.71 (phase I), to 0.67 (phase II), to 0.16 (phase III) events per patient-year at risk (P < 0.001 phase III vs. phases I and II). Similarly, hospital days, missed treatments, and catheter use related to thrombotic events were significantly reduced during phase III compared to phases I and II. Hospital days related to vascular access morbidity and adjusted for patient-year at risk were 1.8, 1.6, and 0.4 and missed dialysis treatments were 0.98, 0.86, and 0.26 treatments per patient-year at risk for phases I, II, and III, respectively (P < 0.001 for phase III vs. phases I and II). Catheter use was also significantly reduced during phases II and III, from 0.29 (phase I) to 0.17 and further to 0.07 catheters per patient-year at risk, respectively (P < 0.05 for phase III vs. phase I). Percutaneous angioplasty procedures increased during phases II and III from 0.09 to 0.32 to 0.54 procedures per patient-year at risk for phases I, II, and III, respectively (P < 0.01 for phase III vs. phase I). When the total cost of treatment for thrombosis-related events for grafts was estimated, it was found that during phase III, the adjusted yearly billed amount was reduced by 49% versus phase I and 54% versus phase II to $158,550. Similar trends in reduced thrombosis-related morbid events and cost were observed for AVFs. VABFM for early detection of vascular access malfunction coupled with preventive intervention reduces thrombosis rates in both polytetrafluoroethylene (PTFE) grafts and native AVFs. While there was a significant increase in the number of angioplasties done during the flow monitoring phase, the comprehensive cost is markedly reduced due to the decreased number of hospitalizations, catheters placed, missed treatments, and surgical interventions. Vascular access blood flow monitoring along with preventive interventions should be the standard of care in chronic hemodialysis patients.
                Bookmark

                Author and article information

                Journal
                Nephrology Dialysis Transplantation
                Nephrology Dialysis Transplantation
                Oxford University Press (OUP)
                0931-0509
                1460-2385
                November 01 2008
                November 01 2008
                : 23
                : 11
                : 3578-3584
                Article
                10.1093/ndt/gfn275
                18511608
                a1da9138-0d4c-4668-badd-30a6f75d3b75
                © 2008
                History

                Comments

                Comment on this article