      Preliminary MRI quality assessment and device acceptance guidelines for a multicenter bioclinical study: the GO Glioblastoma Project.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          It is a major challenge to guarantee homogeneous acquisition during a prospective multicenter magnetic resonance imaging (MRI) study that makes use of different devices. The goal of the multicenter Grand Ouest Glioblastoma Project (GOGP) was to correlate MRI quantitative parameters with biological markers extracted from image-guided biopsies. Therefore, it was essential to ensure spatial coherence of the parameters as well as the signal intensity and homogeneity. The project included the same MRI protocol implemented on six devices from different manufacturers. The key point was the initial acceptance of the imaging devices and protocol sequences. For this purpose, and to allow comparison of quantitative patient data, we propose a specific method for quality assessment. A common quality control based on 10 parameters was established. Three pulse sequences of the clinical project protocol were applied using three test-objects. A fourth test-object was used to assess T1 accuracy. Although geometry-related parameters, signal-to-noise ratio, uniformity, and T1 measurements varied slightly depending on the different devices, they nevertheless remained within the recommendations and expectations of the multicenter project. This kind of quality control procedure should be undertaken as a prerequisite to any multicenter clinical project involving quantitative MRI and comparison of data acquisitions with quantitative biological image-guided biopsies.

          Related collections

          Author and article information

          Journal
          J Neuroimaging
          Journal of neuroimaging : official journal of the American Society of Neuroimaging
          Wiley
          1552-6569
          1051-2284
          Oct 2012
          : 22
          : 4
          Affiliations
          [1 ] PRISM, Université Rennes 1, IFR 140/Biogenouest, 2 Avenue du Professeur Léon Bernard, Rennes, France.
          Article
          10.1111/j.1552-6569.2011.00638.x
          21883622
          a3f3c6eb-8a9b-4454-ac6c-184566663da0
          History

          Comments

          Comment on this article