      Assessment of cerebral blood flow by means of blood-flow-volume measurement in the internal carotid artery: comparative study with a 133xenon clearance technique.

      Stroke; a Journal of Cerebral Circulation
      Adult, Aged, Blood Flow Velocity, Blood Volume Determination, instrumentation, Brain Injuries, physiopathology, Carotid Artery, Internal, ultrasonography, Cerebrovascular Circulation, Female, Humans, Intensive Care Units, Male, Middle Aged, Predictive Value of Tests, Reference Values, Reproducibility of Results, Sensitivity and Specificity, Subarachnoid Hemorrhage, Ultrasonography, Doppler, methods, Xenon Radioisotopes, pharmacokinetics

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We sought to evaluate a new, angle-independent ultrasonic device for assessment of blood flow volume (BFV) in the internal carotid artery (ICA). Nineteen patients and 4 healthy volunteers were enrolled in a comparative study conducted in the Care Unit of the Division of Neurosurgery at UCLA Medical Center. All patients had been admitted because of severe brain injury: 15 patients with severe head trauma (Glasgow Coma Scale score< or =8) and 4 patients with subarachnoid hemorrhage due to aneurysm rupture. In all patients and subjects, cerebral blood flow (CBF) values obtained with the 133xenon-clearance technique were compared with BFV measurements in the ipsilateral ICA. Hemispheric CBF values showed a close and linear correlation with BFV measurements (r=0.76, P<0.0001). Global CBF values showed a higher correlation with the total BFV value obtained from both ICAs (r=0.84, P<0.0001). With 37 mL x min(-1) x 100 g(-1) as a cutoff value for the ischemic range, a BFV value of 220 mL/min would yield a positive predictive value of 91.7% and a negative predictive value of 82.6% (sensitivity 73.3%, specificity 95%). Conversely, BFV sensitivity and specificity were 60% and 96%, respectively, for the hyperemic range defined by a CBF value >55 mL x min(-1) x 100 g(-1) (positive predictive value of 85.7% and negative prediction value of 85.7%). BFV measurements with this new technology proved to accurately correlate with CBF values evaluated by the 133xenon-clearance technique. These results support the implementation of this technique for bedside assessment of cerebral hemodynamics in critically ill neurosurgical patients.

          Related collections

          Author and article information

          Comments

          Comment on this article