          Abstract

          Background

          Gonioscopy-assisted transluminal trabeculectomy is a novel and useful technique for ab interno trabeculotomy. However, gonioscopy-assisted transluminal trabeculectomy is difficult to perform in patients with corneal opacity or in patients with sequelae of cerebral infarction and cervical osteoarthritis with severe limitation of spinal mobility. This is because observing Schlemm’s canal during surgery using gonioscopy is difficult. In this report, we introduce a new and beneficial surgical technique of transluminal trabeculotomy for these patients, using an ophthalmic endoscope for cases in which normal gonioscopy-assisted transluminal trabeculectomy is difficult.

          Case presentation

          Our patient was a 65-year-old Japanese man with cervical osteoarthritis with severe limitation of spinal mobility who showed primary open-angle glaucoma of the right eye. He had limited conversion of his head during surgery because of complications. Therefore, we performed transluminal trabeculotomy using an ophthalmic endoscope. Finally, ab interno trabeculotomy of 200 degrees was achieved by this method, and an average reduction in ocular pressure of 60% from baseline was achieved after surgery, with no major complications.

          Conclusions

          This surgical technique may be useful as an alternative method for normal gonioscopy-assisted transluminal trabeculectomy in difficult cases.

          Electronic supplementary material

          The online version of this article (10.1186/s13256-019-2186-5) contains supplementary material, which is available to authorized users.

          Related collections

          Most cited references6

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Minimally invasive glaucoma surgery: current status and future prospects

          Minimally invasive glaucoma surgery aims to provide a medication-sparing, conjunctival-sparing, ab interno approach to intraocular pressure reduction for patients with mild-to-moderate glaucoma that is safer than traditional incisional glaucoma surgery. The current approaches include: increasing trabecular outflow (Trabectome, iStent, Hydrus stent, gonioscopy-assisted transluminal trabeculotomy, excimer laser trabeculotomy); suprachoroidal shunts (Cypass micro-stent); reducing aqueous production (endocyclophotocoagulation); and subconjunctival filtration (XEN gel stent). The data on each surgical procedure for each of these approaches are reviewed in this article, patient selection pearls learned to date are discussed, and expectations for the future are examined.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Endoscopic goniotomy: early clinical experience in congenital glaucoma.

            To review the technique and early outcomes of endoscopic goniotomy (EG) in children with opaque corneas and primary congenital glaucoma (PCG) or developmental glaucoma with ocular or systemic anomalies (DG). EG was performed for approximately 300 degrees of the angle through temporal and superonasal corneal incisions. We retrospectively reviewed consecutive cases from 2003 to 2007. Primary outcome was intraocular pressure (IOP) change from baseline to last postoperative visit. Success was defined as IOP < or=21 mm Hg with or without medication but no further surgical intervention. Fourteen eyes of 8 patients (4 PCG, 4 DG) were included. Mean age at surgery was 3.88+/-3.72 months. The reduction in IOP from baseline to the last follow-up visit was -16.7+/-16.7 mm Hg. Success was achieved in 6 of the 16 eyes (Total=43%, PCG=50%, DG=30%). Corneal diameter and axial length remained stable in all eyes. Two patients with DG needed additional surgery after 8 to 9 months. Complications included cataract and zonular dialysis both in 2 patients with aniridia. This pilot study indicates that EG shows reasonable potential for IOP control in congenital glaucoma. The safety and efficacy of EG needs to be further studied with a larger sample size and comparison to other angle surgery techniques.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Endoscopically controlled goniosynechialysis in managing synechial angle-closure glaucoma.

              To propose a new surgical technique for optimized visualization of the chamber angle using ophthalmic microendoscope in goniosynechialysis (GSL). Patients who had acute angle-closure glaucoma with peripheral anterior synechiae or patients with flat anterior chamber after trabeculectomy underwent endoscopically controlled GSL. Ophthalmic endoscope was used before, during, and immediately after GSL to minimize the procedure of GSL and to ensure that the trabecular meshwork was exposed and the majority of the angle was opened after endoscopically controlled GSL. Intraoperative complications, postoperative visual acuity, intraocular pressures (IOPs), and complications were all evaluated. Twelve eyes of twelve patients underwent the operation and the mean follow-up was 7.4+/-1.4 months (range: 6 to 10 mo). The mean preoperative IOP was 42.89+/-15.81 mm Hg. The mean postoperative IOP at the most recent follow-up was 12.72+/-3.48 mm Hg. The absolute success rate (IOP <21 mm Hg without medication) was 8 of 10. Visual acuity improved in 11 of 12 patients (91.7%). No significant intraoperative complications, such as iridodialysis, occurred in any patient. Postoperative complications included hyphema and transient corneal decompensation. Endoscope conveniently provided the surgeon an optimized visualization of the anterior chamber angle. This enhanced visualization and convenience promises accuracy and safety when performing GSL.
                Bookmark

                Author and article information

                Contributors
                nakaoi2@cc.saga-u.ac.jp
                tadashimine@yahoo.co.jp
                sj6506@cc.saga-u.ac.jp
                +81-95-234-2384 , enaida@cc.saga-u.ac.jp
                Journal
                J Med Case Rep
                J Med Case Rep
                Journal of Medical Case Reports
                BioMed Central (London )
                1752-1947
                11 August 2019
                11 August 2019
                2019
                : 13
                : 249
                Affiliations
                ISNI 0000 0001 1172 4459, GRID grid.412339.e, Department of Ophthalmology, Faculty of Medicine, , Saga University, ; Saga, 849-8501 Japan
                Article
                2186
                10.1186/s13256-019-2186-5
                6689328
                31400769
                a758f8c1-f931-47b2-ab23-e449d95405c5
                © The Author(s). 2019

                Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 16 May 2019
                : 2 July 2019
                Funding
                Funded by: Scientific Research from the Japanese Ministry of Education, Culture, Sports, Science and Technology.
                Award ID: #18K09451
                Award Recipient :
                Categories
                Case Report
                Custom metadata
                © The Author(s) 2019

                Medicine
                transluminal trabeculotomy,ab interno trabeculotomy,ophthalmic endoscopy,corneal opacity,cervical osteoarthritis

                Comments

                Comment on this article