93
views
0
recommends
+1 Recommend
1 collections
    4
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Implementation of a program to improve the quality of colonoscopy increases the neoplasia detection rate: a prospective study

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background and study aims: Endoscopists worldwide have been encouraged to report quality indicators in order to evaluate their performance. We aimed to determine whether a program to improve the quality of colonoscopy results in better rates of neoplasia detection.

          Patients and methods: This is a prospective study set in a private endoscopy center. From May 2009 to March 2010, we evaluated 1573 consecutive colonoscopies (group 1). After the implementation of a quality program, from February 2011 to January 2012, we prospectively evaluated 1583 colonoscopies (group 2). Our quality-enhancing intervention consisted of instructing both patients and endoscopists. We measured the cecal intubation rate and the neoplasia detection rate. Overall neoplasias, high-risk adenomas, carcinomas, right colon adenomas, and adenomas detected in screening studies were analyzed.

          Results: Cecal intubation was documented in 1384 cases from group 1 (88 %) and 1534 from group 2 (96.9 %) ( P < 0.0001). The neoplasia detection rates in groups 1 and 2 were, respectively: neoplasias 288 (18.3 %) and 427 (27 %) ( P < 0.0001), high-risk adenomas 76 (4.8 %) and 142 (9 %) ( P < 0.0001), carcinomas 16 (1 %) and 21 (1.3 %) ( P = 0.52), right colon adenomas 112 (7.1 %) and 154 (9.7 %) ( P = 0.01), and adenomas 141 (16.5 %) and 233 (28 %) ( P < 0.0001).

          Conclusions: Implementation of a quality program improves the neoplasia detection rate. Because of the small number of cancerous lesions found in both groups, we were unable to identify differences in the carcinoma detection rate.

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: not found

          Quality indicators for colonoscopy and the risk of interval cancer.

          Although rates of detection of adenomatous lesions (tumors or polyps) and cecal intubation are recommended for use as quality indicators for screening colonoscopy, these measurements have not been validated, and their importance remains uncertain. We used a multivariate Cox proportional-hazards regression model to evaluate the influence of quality indicators for colonoscopy on the risk of interval cancer. Data were collected from 186 endoscopists who were involved in a colonoscopy-based colorectal-cancer screening program involving 45,026 subjects. Interval cancer was defined as colorectal adenocarcinoma that was diagnosed between the time of screening colonoscopy and the scheduled time of surveillance colonoscopy. We derived data on quality indicators for colonoscopy from the screening program's database and data on interval cancers from cancer registries. The primary aim of the study was to assess the association between quality indicators for colonoscopy and the risk of interval cancer. A total of 42 interval colorectal cancers were identified during a period of 188,788 person-years. The endoscopist's rate of detection of adenomas was significantly associated with the risk of interval colorectal cancer (P=0.008), whereas the rate of cecal intubation was not significantly associated with this risk (P=0.50). The hazard ratios for adenoma detection rates of less than 11.0%, 11.0 to 14.9%, and 15.0 to 19.9%, as compared with a rate of 20.0% or higher, were 10.94 (95% confidence interval [CI], 1.37 to 87.01), 10.75 (95% CI, 1.36 to 85.06), and 12.50 (95% CI, 1.51 to 103.43), respectively (P=0.02 for all comparisons). The adenoma detection rate is an independent predictor of the risk of interval colorectal cancer after screening colonoscopy. 2010 Massachusetts Medical Society
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Colonoscopic withdrawal times and adenoma detection during screening colonoscopy.

            Colonoscopy is commonly used to screen for neoplasia. To assess the performance of screening colonoscopy in everyday practice, we conducted a study of the rates of detection of adenomas and the amount of time taken to withdraw the colonoscope among endoscopists in a large community-based practice. During a 15-month period, 12 experienced gastroenterologists performed 7882 colonoscopies, of which 2053 were screening examinations in subjects who had not previously undergone colonoscopy. We recorded the numbers, sizes, and histologic features of the neoplastic lesions detected during screening, as well as the duration of insertion and of withdrawal of the colonoscope during the procedure. We compared rates of detection of neoplastic lesions among gastroenterologists who had mean colonoscopic withdrawal times of less than 6 minutes with the rates of those who had mean withdrawal times of 6 minutes or more. According to experts, 6 minutes is the minimum length of time to allow adequate inspection during instrument withdrawal. Neoplastic lesions (mostly adenomatous polyps) were detected in 23.5% of screened subjects. There were large differences among gastroenterologists in the rates of detection of adenomas (range of the mean number of lesions per subject screened, 0.10 to 1.05; range of the percentage of subjects with adenomas, 9.4 to 32.7%) and in their times of withdrawal of the colonoscope from the cecum to the anus (range, 3.1 to 16.8 minutes for procedures during which no polyps were removed). As compared with colonoscopists with mean withdrawal times of less than 6 minutes, those with mean withdrawal times of 6 minutes or more had higher rates of detection of any neoplasia (28.3% vs. 11.8%, P<0.001) and of advanced neoplasia (6.4% vs. 2.6%, P=0.005). In this large community-based gastroenterology practice, we observed greater rates of detection of adenomas among endoscopists who had longer mean times for withdrawal of the colonoscope. The effect of variation in withdrawal times on lesion detection and the prevention of colorectal cancer in the context of widespread colonoscopic screening is not known. Ours was a preliminary study, so the generalizability and implications for clinical practice need to be determined by future studies. 2006 Massachusetts Medical Society
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Quality in the technical performance of colonoscopy and the continuous quality improvement process for colonoscopy: recommendations of the U.S. Multi-Society Task Force on Colorectal Cancer.

                Bookmark

                Author and article information

                Journal
                Endosc Int Open
                Endosc Int Open
                10.1055/s-0034-1377934
                Endoscopy International Open
                © Georg Thieme Verlag KG (Stuttgart · New York )
                2364-3722
                2196-9736
                January 2016
                11 January 2016
                : 4
                : 1
                : E68-E72
                Affiliations
                Centro Integral de Gastroenterología, Buenos Aires, Argentina.
                Author notes
                Corresponding author Luis Alberto Viola Centro Integral de Gastroenteologia Buenos AiresArgentina violaluis@ 123456yahoo.com
                Article
                10.1055/s-0041-107800
                4713174
                a8a6e198-96ea-4612-82a2-cae6f203ef48
                © Thieme Medical Publishers
                History
                Categories
                Article

                Comments

                Comment on this article