      Validation of specimen pooling using the Cepheid Xpert Xpress SARS-CoV-2 assay

      letter

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Sir, Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) disease (COVID-19) is the latest respiratory tract viral disease to be declared a global pandemic. 1 Throughout the pandemic, laboratory diagnosis of SARS-CoV-2 infection in individual patients has underpinned contact tracing efforts performed by Australian government health departments. The current gold standard for the laboratory detection of SARS-CoV-2 infection (e.g., nasal and/or throat swab) is real-time reverse-transcriptase polymerase chain reaction (RT-PCR) for SARS-CoV-2 nucleic acid. 2 One of the most widely adopted commercial tests is the Cepheid Xpert Xpress SARS-CoV-2 test 3 (Cepheid, USA), a rapid automated molecular test that targets two SARS-CoV-2 coding regions, genes E (envelope) and N2 (nucleocapsid). The claimed limit of detection (LOD) is 250 copies/mL, however, the analytical sensitivity of this assay may be higher with a limit of detection ≤100 copies/mL. 3 The overwhelming demand for SARS-CoV-2 testing has placed significant pressure on laboratory resources globally, including the economic burden associated with mass testing but also physical limits in the availability of reagents for nucleic acid extraction and RT-PCR testing. Alongside this is the recognition that, particularly in jurisdictions where the SARS-CoV-2 prevalence has been low, the majority of samples tested from individuals are negative. For example, in a 2-week period in Australia between 28 September 2020 and 11 October 2020, 461,888 PCR tests were conducted to diagnose COVID-19 with a positivity rate of 0.05% reported. 4 To maintain cost effective levels of testing required for diagnosis and contract tracing, laboratories around the world have explored the efficacy of sample pooling during peak demand, whereby pools of patient samples (of variable size) are initially processed and tested together, and the individual samples present in positive pools are subsequently retested. A number of recent studies have reported that sample pooling strategies are an effective and economical approach to SARS-CoV-2 screening.5, 6, 7, 8 As expected, sensitivity was lowest in larger pools of samples or in samples with a higher cycle threshold. 6 , 8 A comparison of pooling strategies involving sample grouping before or after RNA extraction found that pooling of samples before RNA extraction is preferred for SARS-CoV-2 testing. 6 In our diagnostic microbiology laboratory, the GeneXpert Xpress SARS-CoV-2 assay has been used to support rapid testing of patients presenting to the hospital’s emergency department and other hospital departments during periods of high demand and restricted supply of reagents. To support its use in this setting, in the current study, we performed a fit for purpose validation of specimen pooling using the Xpert Xpress SARS-CoV-2 assay. Sample pooling protocols using different pool sizes were evaluated for use in combination with a diagnostic panel. To determine the LOD of the Xpert Xpress SARS-CoV-2 assay, a 10-fold dilution series of a high viral load clinical specimen was prepared by dilution using unopened viral transport medium (Tréidlia Biovet, Australia). The LOD dilution series were tested in duplicate to assess reproducibility using the Xpert Xpress SARS-CoV-2 assay on the GeneXpert Dx system (Cepheid, USA). Actual viral copy number per mL of the diluted samples was assessed using an in-house assay targeting SARS-CoV-2 N and orf1ab genes and a standard quantification curve at the NSWHP, Institute of Clinical Pathology and Medical Research (ICPMR) Westmead Laboratory, to assist with determining the LOD of the Xpert Xpress SARS-CoV-2 assay. To evaluate the impact of sampling pooling, confirmed SARS-CoV-2 negative specimens were used as diluent to simulate specimen pooling of clinical specimens with specimens from the 10-fold dilution series in the range of 10-4 to 10-9. Specimen pooling ratios of 4, 6 and 8 specimens were then assessed. Practically, prior to loading the Xpert Xpress SARS-CoV-2 cartridge, 100 μL of each specimen was added to a 2 mL microcentrifuge tube to represent each pooling ratio and then mixed by inversion five times; 300 μL of the pooled specimen was then loaded into the cartridge using the sterile pipet provided. Cycle threshold values for the SARS-CoV-2 E and N2 genes were then compared against the results obtained from testing neat specimen in order to verify the utility and performance of each specimen pooling ratio. To simulate the ‘real-world’ impact of sample pooling, an additional set of patient specimens (n=124) were tested neat and also in a 4:1 dilution pool to further validate the latter sample pooling ratio. With the exception of 10-8 and 10-9, the presence of SARS-CoV-2 could be detected at other dilutions for both genes up to 10-7 (Ct∼37–40), equivalent to 2 SARS-CoV-2 copies/mL (data not shown). These dilutions represented the assay’s limit of detection with viral loads significantly higher than those detected in individuals considered infectious with SARS-CoV-2. 3 Sample pooling revealed that at a 4:1 dilution, the Ct values varied from between 1.1 to 3.4 across the different dilutions and genes tested with an average Ct variation of 1.9 to 2.7 for SARS-CoV-2 E and N2 gene assays (compared to the neat specimen), respectively (Table 1 ). For pools of six samples, the Ct values varied from 1.3 to 4.0 when compared with the neat specimen across the dilutions and target genes with an average change in the Ct of 2.6 and 2.7 for SARS-CoV-2 E and N2 genes. Pools of eight samples showed the largest variation in Ct value from the neat specimen with Ct values ranging between 2.8 to 8.2 and an average variation in the Ct of 3.3 and 3.5 for SARS-CoV-2 E and N2 genes. To further validate a 4:1 sample dilution ratio, we tested an additional 124 patient specimens prospectively. Five neat specimens were found to be positive (Ct range 12.7–22.9). All of these specimens were also found positive in 4:1 diluted pool with an average change in the Ct of 1.4 and 1.5 for SARS-CoV-2 E and N2 genes, respectively (data not shown). Table 1 Results of GeneXpert Xpress SARS-CoV-2 assay pooling of clinical specimens Table 1 Pooling protocol Average Δ pool CtE gene Average Δ pool CtN2 gene 4 to 1 1.9 2.7 6 to 1 2.6 2.7 8 to 1 3.3 3.5 The results of these fit for purpose experiments suggest that sample pooling is a viable option to allow for higher throughput/reagent savings in medium to low SARS-CoV-2 prevalence settings. Based on our comparison of different pool sizes, the optimal selected protocol involved the pooling of four samples, where only one sample may be positive and, in effect, diluting the positive specimen 1:4. This result is consistent with the results of similar experiments described by Chong et al. 8 with an increase in Ct values following sample pooling, consistent with our own study despite the authors using a different SARS-CoV-2 assay. These authors also concluded that pools of four samples are the optimal pool size, trading assay sensitivity for a notable increase in the efficiency of sample testing. The latter study further concluded that this pooling strategy would be ideal for testing large numbers of samples with very low test-probability, even when there were no concerns over reagent access. 8 Based on these results, we successfully introduced this sample pooling strategy as a component of our local diagnostic microbiology surge response to outbreaks of SARS-CoV-2 in Western Sydney between June and October 2021, 9 reserving pooled specimens for lower risk patients. In the USA, specimen pooling has been approved as a strategy to increase screening testing capacity for SARS-CoV-2 assays approved for use by the FDA. 10 Pooling of specimens on the GeneXpert platform is not currently endorsed by the manufacturer and laboratories are required to accredit this variation with NATA as in-house in vitro diagnostic device (IVD). Of note, NSWHP laboratories are NATA accredited for pooling on several other SARS-CoV-2 NAT assays. The work described in this study, involving pragmatic changes to diagnostic procedures to conserve critical diagnostic reagents, highlights the importance of flexibility in managing a laboratory response to the challenges presented by COVID-19 and other new and emerging infectious disease threats now and into the future. Conflicts of interest and sources of funding The authors state that there are no conflicts of interest to disclose.

          Related collections

          Most cited references9

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Virology, Epidemiology, Pathogenesis, and Control of COVID-19

          The outbreak of emerging severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) disease (COVID-19) in China has been brought to global attention and declared a pandemic by the World Health Organization (WHO) on March 11, 2020. Scientific advancements since the pandemic of severe acute respiratory syndrome (SARS) in 2002~2003 and Middle East respiratory syndrome (MERS) in 2012 have accelerated our understanding of the epidemiology and pathogenesis of SARS-CoV-2 and the development of therapeutics to treat viral infection. As no specific therapeutics and vaccines are available for disease control, the epidemic of COVID-19 is posing a great threat for global public health. To provide a comprehensive summary to public health authorities and potential readers worldwide, we detail the present understanding of COVID-19 and introduce the current state of development of measures in this review.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Multicenter Evaluation of the Cepheid Xpert Xpress SARS-CoV-2 Test

            Nucleic acid amplification tests (NAATs) are the primary means of identifying acute infections caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Accurate and fast test results may permit more efficient use of protective and isolation resources and allow rapid therapeutic interventions. We evaluated the analytical and clinical performance characteristics of the Xpert Xpress SARS-CoV-2 (Xpert) test, a rapid, automated molecular test for SARS-CoV-2. Analytical sensitivity and specificity/interference were assessed with infectious SARS-CoV-2; other infectious coronavirus species, including SARS-CoV; and 85 nasopharyngeal swab specimens positive for other respiratory viruses, including endemic human coronaviruses (hCoVs).
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A pooled testing strategy for identifying SARS-CoV-2 at low prevalence

              Suppressing infections of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) will probably require the rapid identification and isolation of individuals infected with the virus on an ongoing basis. Reverse-transcription polymerase chain reaction (RT-PCR) tests are accurate but costly, which makes the regular testing of every individual expensive. These costs are a challenge for all countries around the world, but particularly for low-to-middle-income countries. Cost reductions can be achieved by pooling (or combining) subsamples and testing them in groups1-7. A balance must be struck between increasing the group size and retaining test sensitivity, as sample dilution increases the likelihood of false-negative test results for individuals with a low viral load in the sampled region at the time of the test8. Similarly, minimizing the number of tests to reduce costs must be balanced against minimizing the time that testing takes, to reduce the spread of the infection. Here we propose an algorithm for pooling subsamples based on the geometry of a hypercube that, at low prevalence, accurately identifies individuals infected with SARS-CoV-2 in a small number of tests and few rounds of testing. We discuss the optimal group size and explain why, given the highly infectious nature of the disease, largely parallel searches are preferred. We report proof-of-concept experiments in which a positive subsample was detected even when diluted 100-fold with negative subsamples (compared with 30-48-fold dilutions described in previous studies9-11). We quantify the loss of sensitivity due to dilution and discuss how it may be mitigated by the frequent re-testing of groups, for example. With the use of these methods, the cost of mass testing could be reduced by a large factor. At low prevalence, the costs decrease in rough proportion to the prevalence. Field trials of our approach are under way in Rwanda and South Africa. The use of group testing on a massive scale to monitor infection rates closely and continually in a population, along with the rapid and effective isolation of people with SARS-CoV-2 infections, provides a promising pathway towards the long-term control of coronavirus disease 2019 (COVID-19).
                Bookmark

                Author and article information

                Journal
                Pathology
                Pathology
                Pathology
                Published by Elsevier B.V. on behalf of Royal College of Pathologists of Australasia.
                0031-3025
                1465-3931
                2 February 2022
                2 February 2022
                Affiliations
                [1 ]Department of Microbiology and Infectious Diseases, New South Wales Health Pathology-Nepean, Penrith, NSW, Australia
                [2 ]New South Wales Health Pathology - Public Health Pathology State-wide Service, Westmead, NSW, Australia
                [3 ]Nepean Clinical School, Faculty of Medicine and Health, University of Sydney, Kingswood, NSW, Australia
                Author notes
                []Corresponding author.
                Article
                S0031-3025(22)00036-8
                10.1016/j.pathol.2021.12.286
                8808749
                a8f4cf21-70df-45cb-8b3f-1edbfd4ced51
                © 2022 Published by Elsevier B.V. on behalf of Royal College of Pathologists of Australasia.

                Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.

                History
                : 11 October 2021
                : 7 December 2021
                : 15 December 2021
                Categories
                Correspondence

                Comments

                Comment on this article