12
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Allergy in total knee arthroplasty: a review of the facts.

      The Bone & Joint Journal
      British Editorial Society of Bone & Joint Surgery
      allergy, Total knee arthroplasty, metal hypersensitivity

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We explored the literature surrounding whether allergy and hypersensitivity has a clinical basis for implant selection in total knee arthroplasty (TKA). In error, the terms hypersensitivity and allergy are often used synonymously. Although a relationship is present, we could not find any evidence of implant failure due to allergy. There is however increasing basic science that suggests a link between loosening and metal ion production. This is not an allergic response but is a potential problem. With a lack of evidence logically there can be no justification to use 'hypoallergenic' implants in patients who have pre-existing skin sensitivity to the metals used in TKA.

          Related collections

          Most cited references36

          • Record: found
          • Abstract: found
          • Article: not found

          Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study.

          Some patients who have a total hip replacement with a second-generation metal-on-metal articulation have persistent or early recurrence of preoperative symptoms. Characteristic histological changes in the periprosthetic tissues suggested the development of an immunological response. Therefore, in order to determine the relevance of these symptoms, we performed a study of the clinical data and periprosthetic tissues associated with endoprostheses with a metal-on metal articulation that had been retrieved at revision. Periprosthetic tissues as well as the clinical data on the patients were obtained from the first nineteen consecutive revisions performed at the treating hospitals. At the time of the revision, fourteen patients had the metal-on-metal articulation exchanged for either an alumina-ceramic or a metal-on-polyethylene articulation. Five patients received another second-generation metal-on-metal total joint replacement. Five-micrometer sections were prepared from the tissue samples, were stained with routine and immunohistochemical methods, and were examined histologically. Histological specimens from three groups of patients, two of which were treated with non-metal-on-metal implants, served as controls. The majority of patients had persistence of their preoperative pain or early recurrence of the pain after the original total hip replacement, and often a pronounced hip joint effusion had developed after the original replacement. Radiographic follow-up showed the development of radiolucent lines in five hips and of osteolysis in another seven hips. At the revision surgery, both the cup and the stem were found to be well fixed in nine patients. The characteristic histological features were diffuse and perivascular infiltrates of T and B lymphocytes and plasma cells, high endothelial venules, massive fibrin exudation, accumulation of macrophages with droplike inclusions, and infiltrates of eosinophilic granulocytes and necrosis. Only a few metal particles were detected. Immunohistochemical analysis demonstrated that the cellular reaction was still active. The patients who received another second-generation metal-on-metal articulation at the time of the revision had no decrease in symptoms. In the control group of tissues obtained at revisions of endoprostheses without cobalt, chromium, or nickel articulations, there were no similar signs of immune reactions. These histological findings support the possibility of a lymphocyte-dominated immunological response. Although the prevalence of this reaction is low, the persistence or early reappearance of symptoms, including a marked joint effusion and the development of osteolysis, after primary implantation may suggest the possibility of such a reaction.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

            Aseptic loosening and other wear-related complications are some of the most frequent late reasons for revision of total knee arthroplasty (TKA). Periprosthetic osteolysis (PPOL) pre-dates aseptic loosening in many cases, indicating the clinical significance of this pathogenic mechanism. A variety of implant-, surgery- and host-related factors have been delineated to explain the development of PPOL. These factors influence the development of PPOL because of changes in mechanical stresses within the vicinity of the prosthetic device, excessive wear of the polyethylene liner, and joint fluid pressure and flow acting on the peri-implant bone. The process of aseptic loosening is initially governed by factors such as implant/limb alignment, device fixation quality and muscle coordination/strength. Later, large numbers of wear particles detached from TKA trigger and perpetuate particle disease, as highlighted by progressive growth of inflammatory/granulomatous tissue around the joint cavity. An increased accumulation of osteoclasts at the bone-implant interface, impairment of osteoblast function, mechanical stresses and increased production of joint fluid contribute to bone resorption and subsequent loosening of the implant. In addition, hypersensitivity and adverse reactions to metal debris may contribute to aseptic TKA failure, but should be determined more precisely. Patient activity level appears to be the most important factor when the long-term development of PPOL is considered. Surgical technique, implant design and material factors are the most important preventative factors, because they influence both the generation of wear debris and excessive mechanical stresses. New generations of bearing surfaces and designs for TKA should carefully address these important issues in extensive preclinical studies. Currently, there is little evidence that PPOL can be prevented by pharmacological intervention.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The role of macrophages in osteolysis of total joint replacement.

              The osteolysis associated with conventional polyethylene on metal total joint replacements is associated with the formation of an inflamed periprosthetic membrane rich in macrophages, cytokines and implant-derived wear particles. There is a wealth of evidence to indicate that the presence and activation of macrophages in the periprosthetic tissues around joint replacements is stimulated by UHMWPE particles. Particles within the size range 0.1-1.0 microm have been shown to be the most reactive. Animal studies have provided increasing evidence that, of the milieu of cytokines produced by particle-stimulated macrophages, TNF-alpha is a key cytokine involved in osteolysis. Recent advances in the understanding of the mechanisms of osteoclastogenesis and osteoclast activation at the cellular and molecular level have indicated that bone marrow-derived macrophages may play a dual role in osteolysis associated with total joint replacement. Firstly, as the major cell in host defence responding to UHMWPE particles via the production of cytokines and secondly as precursors for the osteoclasts responsible for the ensuing bone resorption.
                Bookmark

                Author and article information

                Journal
                27037424
                10.1302/0301-620X.98B4.36767

                allergy,Total knee arthroplasty,metal hypersensitivity

                Comments

                Comment on this article